Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis

© 2018 Liew et al. Background. There is convincing evidence for the benefits of resistance training on vertical jump improvements, but little evidence to guide optimal training prescription. The inability to detect small between modality effects may partially reflect the use of ANOVA statistics. Th...

Full description

Bibliographic Details
Main Authors: Liew, B., Drovandi, C., Clifford, S., Keogh, J., Morris, Susan, Netto, Kevin
Format: Journal Article
Published: PeerJ, Ltd. 2018
Online Access:http://hdl.handle.net/20.500.11937/66919
_version_ 1848761426881019904
author Liew, B.
Drovandi, C.
Clifford, S.
Keogh, J.
Morris, Susan
Netto, Kevin
author_facet Liew, B.
Drovandi, C.
Clifford, S.
Keogh, J.
Morris, Susan
Netto, Kevin
author_sort Liew, B.
building Curtin Institutional Repository
collection Online Access
description © 2018 Liew et al. Background. There is convincing evidence for the benefits of resistance training on vertical jump improvements, but little evidence to guide optimal training prescription. The inability to detect small between modality effects may partially reflect the use of ANOVA statistics. This study represents the results of a sub-study from a larger project investigating the effects of two resistance training methods on load carriage running energetics. Bayesian statistics were used to compare the effectiveness of isoinertial resistance against speed-power training to change countermovement jump (CMJ) and squat jump (SJ) height, and joint energetics. Methods. Active adults were randomly allocated to either a six-week isoinertial (nD 16; calf raises, leg press, and lunge), or a speed-power training program (n D 14; countermovement jumps, hopping, with hip flexor training to target pre-swing running energetics). Primary outcome variables included jump height and joint power. Bayesian mixed modelling and Functional Data Analysis were used, where significance was determined by a non-zero crossing of the 95% Bayesian Credible Interval (CrI). Results. The gain in CMJ height after isoinertial training was 1.95 cm (95% CrI [0.85-3.04] cm) greater than the gain after speed-power training, but the gain in SJ height was similar between groups. In the CMJ, isoinertial training produced a larger increase in power absorption at the hip by a mean 0.018% (equivalent to 35 W) (95% CrI [0.007-0.03] ), knee by 0.014% (equivalent to 27 W) (95% CrI [0.006-0.02]) and foot by 0.011% (equivalent to 21 W) (95% CrI [0.005-0.02] ) compared to speed-power training. Discussion. Short-term isoinertial training improved CMJ height more than speed- power training. The principle adaptive difference between training modalities was at the level of hip, knee and foot power absorption.
first_indexed 2025-11-14T10:31:29Z
format Journal Article
id curtin-20.500.11937-66919
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:31:29Z
publishDate 2018
publisher PeerJ, Ltd.
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-669192018-05-18T08:07:19Z Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis Liew, B. Drovandi, C. Clifford, S. Keogh, J. Morris, Susan Netto, Kevin © 2018 Liew et al. Background. There is convincing evidence for the benefits of resistance training on vertical jump improvements, but little evidence to guide optimal training prescription. The inability to detect small between modality effects may partially reflect the use of ANOVA statistics. This study represents the results of a sub-study from a larger project investigating the effects of two resistance training methods on load carriage running energetics. Bayesian statistics were used to compare the effectiveness of isoinertial resistance against speed-power training to change countermovement jump (CMJ) and squat jump (SJ) height, and joint energetics. Methods. Active adults were randomly allocated to either a six-week isoinertial (nD 16; calf raises, leg press, and lunge), or a speed-power training program (n D 14; countermovement jumps, hopping, with hip flexor training to target pre-swing running energetics). Primary outcome variables included jump height and joint power. Bayesian mixed modelling and Functional Data Analysis were used, where significance was determined by a non-zero crossing of the 95% Bayesian Credible Interval (CrI). Results. The gain in CMJ height after isoinertial training was 1.95 cm (95% CrI [0.85-3.04] cm) greater than the gain after speed-power training, but the gain in SJ height was similar between groups. In the CMJ, isoinertial training produced a larger increase in power absorption at the hip by a mean 0.018% (equivalent to 35 W) (95% CrI [0.007-0.03] ), knee by 0.014% (equivalent to 27 W) (95% CrI [0.006-0.02]) and foot by 0.011% (equivalent to 21 W) (95% CrI [0.005-0.02] ) compared to speed-power training. Discussion. Short-term isoinertial training improved CMJ height more than speed- power training. The principle adaptive difference between training modalities was at the level of hip, knee and foot power absorption. 2018 Journal Article http://hdl.handle.net/20.500.11937/66919 10.7717/peerj.4620 PeerJ, Ltd. restricted
spellingShingle Liew, B.
Drovandi, C.
Clifford, S.
Keogh, J.
Morris, Susan
Netto, Kevin
Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis
title Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis
title_full Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis
title_fullStr Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis
title_full_unstemmed Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis
title_short Joint-level energetics differentiate isoinertial from speed-power resistance training-a Bayesian analysis
title_sort joint-level energetics differentiate isoinertial from speed-power resistance training-a bayesian analysis
url http://hdl.handle.net/20.500.11937/66919