Reliability and availability for substation communication systems using IEC61850
The use of IEC 61850 for substation automation system (SAS) has enabled interoperability among the communication devices from different vendors but the IEC 61850 does not specifies any particular type of communication architecture for a particular type of substation and neither it demands any redund...
| Main Authors: | , , |
|---|---|
| Other Authors: | |
| Format: | Conference Paper |
| Published: |
IEEE
2013
|
| Subjects: | |
| Online Access: | http://hdl.handle.net/20.500.11937/6126 |
| _version_ | 1848744987098873856 |
|---|---|
| author | Das, Narottam Singh, Satinderpal Islam, Syed |
| author2 | Not known |
| author_facet | Not known Das, Narottam Singh, Satinderpal Islam, Syed |
| author_sort | Das, Narottam |
| building | Curtin Institutional Repository |
| collection | Online Access |
| description | The use of IEC 61850 for substation automation system (SAS) has enabled interoperability among the communication devices from different vendors but the IEC 61850 does not specifies any particular type of communication architecture for a particular type of substation and neither it demands any redundancy for even critical substation functions. However, it demands for the communication architecture with zero point of failure. Therefore, it is important to analyse the reliability and availability of the communication topologies used for the SAS. This paper demonstrates how the reliability block diagrams (RBD’s) can be used to calculate the reliability and availability of the different communication topologies for substation automation. Further, the results are compared and analysed to find the most reliable topology for the SAS of a typical substation layout. |
| first_indexed | 2025-11-14T06:10:11Z |
| format | Conference Paper |
| id | curtin-20.500.11937-6126 |
| institution | Curtin University Malaysia |
| institution_category | Local University |
| last_indexed | 2025-11-14T06:10:11Z |
| publishDate | 2013 |
| publisher | IEEE |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | curtin-20.500.11937-61262017-02-28T01:30:24Z Reliability and availability for substation communication systems using IEC61850 Das, Narottam Singh, Satinderpal Islam, Syed Not known Substation automation system (SAS) Reliability Block Diagram (RBD) IEC 61850 Communication Topology Reliability and Availability The use of IEC 61850 for substation automation system (SAS) has enabled interoperability among the communication devices from different vendors but the IEC 61850 does not specifies any particular type of communication architecture for a particular type of substation and neither it demands any redundancy for even critical substation functions. However, it demands for the communication architecture with zero point of failure. Therefore, it is important to analyse the reliability and availability of the communication topologies used for the SAS. This paper demonstrates how the reliability block diagrams (RBD’s) can be used to calculate the reliability and availability of the different communication topologies for substation automation. Further, the results are compared and analysed to find the most reliable topology for the SAS of a typical substation layout. 2013 Conference Paper http://hdl.handle.net/20.500.11937/6126 IEEE restricted |
| spellingShingle | Substation automation system (SAS) Reliability Block Diagram (RBD) IEC 61850 Communication Topology Reliability and Availability Das, Narottam Singh, Satinderpal Islam, Syed Reliability and availability for substation communication systems using IEC61850 |
| title | Reliability and availability for substation communication systems using IEC61850 |
| title_full | Reliability and availability for substation communication systems using IEC61850 |
| title_fullStr | Reliability and availability for substation communication systems using IEC61850 |
| title_full_unstemmed | Reliability and availability for substation communication systems using IEC61850 |
| title_short | Reliability and availability for substation communication systems using IEC61850 |
| title_sort | reliability and availability for substation communication systems using iec61850 |
| topic | Substation automation system (SAS) Reliability Block Diagram (RBD) IEC 61850 Communication Topology Reliability and Availability |
| url | http://hdl.handle.net/20.500.11937/6126 |