Improvement of DGA interpretation using scoring index method

© 2017 IEEE. Dissolved gas analysis (DGA) is the most effective method to detect incipient faults in power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition of the oil and paper insulation. Gases such as hydrogen, methane, acetylene, ethy...

Full description

Bibliographic Details
Main Authors: Bakar, N., Abu-Siada, Ahmed, Cui, H., Li, S.
Format: Conference Paper
Published: 2017
Online Access:http://hdl.handle.net/20.500.11937/56751
_version_ 1848759929678069760
author Bakar, N.
Abu-Siada, Ahmed
Cui, H.
Li, S.
author_facet Bakar, N.
Abu-Siada, Ahmed
Cui, H.
Li, S.
author_sort Bakar, N.
building Curtin Institutional Repository
collection Online Access
description © 2017 IEEE. Dissolved gas analysis (DGA) is the most effective method to detect incipient faults in power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition of the oil and paper insulation. Gases such as hydrogen, methane, acetylene, ethylene, and ethane are generated as a results of oil decomposition, while carbon monoxide and carbon dioxide are generated due to the paper degradation. In the meantime, faults such as partial discharge, overheating, and arcing produce a range of gases. The concentrations of these gases can be used to identify faults and estimate their severity. Various techniques have been developed to interpret DGA results such the key gas method, Doernenburg, Rogers, IEC ratio-based methods, Duval triangles, and the latest Duval Pentagon methods. However, each of these techniques relies on the accumulated knowledge and experience of experts rather than quantitative scientific models, therefore different diagnoses may be reported for the same oil sample. Hence the accountability of the judgment is questionable if it only relies on one interpretation technique. This paper proposes the use of scoring point method to improve the accountability of DGA interpretation process. In this context, DGA results of several transformer oil samples are analyzed with four existing interpretation techniques; Doernenburg, Rogers, IEC, and Duval triangle methods from which a scoring index is developed for all fault types. Based on this analysis, each technique is assigned with specific weighting factor. The summation of scoring point times weightage represents the scoring index for particular faults. The proposed method is validated through DGA historical data of various transformers of pre-known health condition and life span. Results show that the proposed method can increase the accuracy of the DGA interpretation process.
first_indexed 2025-11-14T10:07:42Z
format Conference Paper
id curtin-20.500.11937-56751
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:07:42Z
publishDate 2017
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-567512017-09-27T10:49:12Z Improvement of DGA interpretation using scoring index method Bakar, N. Abu-Siada, Ahmed Cui, H. Li, S. © 2017 IEEE. Dissolved gas analysis (DGA) is the most effective method to detect incipient faults in power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition of the oil and paper insulation. Gases such as hydrogen, methane, acetylene, ethylene, and ethane are generated as a results of oil decomposition, while carbon monoxide and carbon dioxide are generated due to the paper degradation. In the meantime, faults such as partial discharge, overheating, and arcing produce a range of gases. The concentrations of these gases can be used to identify faults and estimate their severity. Various techniques have been developed to interpret DGA results such the key gas method, Doernenburg, Rogers, IEC ratio-based methods, Duval triangles, and the latest Duval Pentagon methods. However, each of these techniques relies on the accumulated knowledge and experience of experts rather than quantitative scientific models, therefore different diagnoses may be reported for the same oil sample. Hence the accountability of the judgment is questionable if it only relies on one interpretation technique. This paper proposes the use of scoring point method to improve the accountability of DGA interpretation process. In this context, DGA results of several transformer oil samples are analyzed with four existing interpretation techniques; Doernenburg, Rogers, IEC, and Duval triangle methods from which a scoring index is developed for all fault types. Based on this analysis, each technique is assigned with specific weighting factor. The summation of scoring point times weightage represents the scoring index for particular faults. The proposed method is validated through DGA historical data of various transformers of pre-known health condition and life span. Results show that the proposed method can increase the accuracy of the DGA interpretation process. 2017 Conference Paper http://hdl.handle.net/20.500.11937/56751 10.1109/ICEMPE.2017.7982139 restricted
spellingShingle Bakar, N.
Abu-Siada, Ahmed
Cui, H.
Li, S.
Improvement of DGA interpretation using scoring index method
title Improvement of DGA interpretation using scoring index method
title_full Improvement of DGA interpretation using scoring index method
title_fullStr Improvement of DGA interpretation using scoring index method
title_full_unstemmed Improvement of DGA interpretation using scoring index method
title_short Improvement of DGA interpretation using scoring index method
title_sort improvement of dga interpretation using scoring index method
url http://hdl.handle.net/20.500.11937/56751