Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque

Hydraulic turbine generator units with long-running operation may cause the values of hydraulic, mechanic or electric parameters changing gradually, which brings a new challenge, namely that whether the operating stability of these units will be changed in the next thirty or forty years. This paper...

Full description

Bibliographic Details
Main Authors: Xu, B., Yan, D., Chen, D., Gao, X., Wu, Changzhi
Format: Journal Article
Published: Elsevier 2017
Online Access:http://hdl.handle.net/20.500.11937/54860
_version_ 1848759481146540032
author Xu, B.
Yan, D.
Chen, D.
Gao, X.
Wu, Changzhi
author_facet Xu, B.
Yan, D.
Chen, D.
Gao, X.
Wu, Changzhi
author_sort Xu, B.
building Curtin Institutional Repository
collection Online Access
description Hydraulic turbine generator units with long-running operation may cause the values of hydraulic, mechanic or electric parameters changing gradually, which brings a new challenge, namely that whether the operating stability of these units will be changed in the next thirty or forty years. This paper is an attempt to seek a relatively unified model for sensitivity analysis from three aspects: hydraulic parameters (turbine flow and turbine head), mechanic parameters (axis coordinates and axial misalignment) and electric parameters (generator speed and excitation current). First, a novel approach of the Pelton turbine torque is proposed, which can make connections between the hydraulic turbine governing system and the shafting system of the hydro-turbine generator unit. Moreover, the correctness of this approach is verified by comparing with other three models of hydropower stations. Second, this latter is analyzed to obtain the sensitivity of electric parameter (excitation current), the mechanic parameters (axial misalignment, upper guide bearing rigidity, lower guide bearing rigidity, and turbine guide bearing rigidity) on hydraulic parameters on the operating stability of the unit. In addition to this, some critical values and ranges are proposed. Finally, these results can provide some bases for the design and stable operation of Peltonhydropower stations.
first_indexed 2025-11-14T10:00:34Z
format Journal Article
id curtin-20.500.11937-54860
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T10:00:34Z
publishDate 2017
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-548602018-03-01T07:10:06Z Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque Xu, B. Yan, D. Chen, D. Gao, X. Wu, Changzhi Hydraulic turbine generator units with long-running operation may cause the values of hydraulic, mechanic or electric parameters changing gradually, which brings a new challenge, namely that whether the operating stability of these units will be changed in the next thirty or forty years. This paper is an attempt to seek a relatively unified model for sensitivity analysis from three aspects: hydraulic parameters (turbine flow and turbine head), mechanic parameters (axis coordinates and axial misalignment) and electric parameters (generator speed and excitation current). First, a novel approach of the Pelton turbine torque is proposed, which can make connections between the hydraulic turbine governing system and the shafting system of the hydro-turbine generator unit. Moreover, the correctness of this approach is verified by comparing with other three models of hydropower stations. Second, this latter is analyzed to obtain the sensitivity of electric parameter (excitation current), the mechanic parameters (axial misalignment, upper guide bearing rigidity, lower guide bearing rigidity, and turbine guide bearing rigidity) on hydraulic parameters on the operating stability of the unit. In addition to this, some critical values and ranges are proposed. Finally, these results can provide some bases for the design and stable operation of Peltonhydropower stations. 2017 Journal Article http://hdl.handle.net/20.500.11937/54860 10.1016/j.enconman.2017.06.019 Elsevier restricted
spellingShingle Xu, B.
Yan, D.
Chen, D.
Gao, X.
Wu, Changzhi
Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque
title Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque
title_full Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque
title_fullStr Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque
title_full_unstemmed Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque
title_short Sensitivity analysis of a Pelton hydropower station based on a novel approach of turbine torque
title_sort sensitivity analysis of a pelton hydropower station based on a novel approach of turbine torque
url http://hdl.handle.net/20.500.11937/54860