Impact of Buckling Deformation on the FRA Signature of Power Transformer

Power transformer is an important asset within the electrical power system network. Frequency Response Analysis (FRA) has been developing in popularity in recent years as a tool to detect mechanical deformation of power transformers winding. Since the FRA has been relying on graphical analysis, it c...

Full description

Bibliographic Details
Main Authors: Amini, Arman, Das, Narottam, Islam, Syed
Other Authors: Michael Negnevitsky
Format: Conference Paper
Published: University of Tasmania 2013
Subjects:
Online Access:http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6725456
http://hdl.handle.net/20.500.11937/5349
_version_ 1848744772168056832
author Amini, Arman
Das, Narottam
Islam, Syed
author2 Michael Negnevitsky
author_facet Michael Negnevitsky
Amini, Arman
Das, Narottam
Islam, Syed
author_sort Amini, Arman
building Curtin Institutional Repository
collection Online Access
description Power transformer is an important asset within the electrical power system network. Frequency Response Analysis (FRA) has been developing in popularity in recent years as a tool to detect mechanical deformation of power transformers winding. Since the FRA has been relying on graphical analysis, it calls for an expert person to analyze the results to detect the type of the fault and its location. There are no reliable guidelines for FRA signature in the event that a failure occurs in service and the impact can be far reaching. The concept of FRA has been successfully used as a diagnostic technique to detect the winding deformation, core and clamping structure for the power transformers. This paper investigated the impact of the forced and free winding buckling based on the variation of the electrical parameters to show how these faults vary the FRA signature.
first_indexed 2025-11-14T06:06:46Z
format Conference Paper
id curtin-20.500.11937-5349
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:06:46Z
publishDate 2013
publisher University of Tasmania
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-53492017-02-28T01:29:30Z Impact of Buckling Deformation on the FRA Signature of Power Transformer Amini, Arman Das, Narottam Islam, Syed Michael Negnevitsky condition monitoring Buckling Fault Frequency Response Analysis (FRA) core and winding deformation Power transformer is an important asset within the electrical power system network. Frequency Response Analysis (FRA) has been developing in popularity in recent years as a tool to detect mechanical deformation of power transformers winding. Since the FRA has been relying on graphical analysis, it calls for an expert person to analyze the results to detect the type of the fault and its location. There are no reliable guidelines for FRA signature in the event that a failure occurs in service and the impact can be far reaching. The concept of FRA has been successfully used as a diagnostic technique to detect the winding deformation, core and clamping structure for the power transformers. This paper investigated the impact of the forced and free winding buckling based on the variation of the electrical parameters to show how these faults vary the FRA signature. 2013 Conference Paper http://hdl.handle.net/20.500.11937/5349 http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6725456 University of Tasmania restricted
spellingShingle condition monitoring
Buckling Fault
Frequency Response Analysis (FRA)
core and winding deformation
Amini, Arman
Das, Narottam
Islam, Syed
Impact of Buckling Deformation on the FRA Signature of Power Transformer
title Impact of Buckling Deformation on the FRA Signature of Power Transformer
title_full Impact of Buckling Deformation on the FRA Signature of Power Transformer
title_fullStr Impact of Buckling Deformation on the FRA Signature of Power Transformer
title_full_unstemmed Impact of Buckling Deformation on the FRA Signature of Power Transformer
title_short Impact of Buckling Deformation on the FRA Signature of Power Transformer
title_sort impact of buckling deformation on the fra signature of power transformer
topic condition monitoring
Buckling Fault
Frequency Response Analysis (FRA)
core and winding deformation
url http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6725456
http://hdl.handle.net/20.500.11937/5349