PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times

To understand the rate determining processes during the equilibration of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate-based (PEDOT(PSS)-based) solid contact (SC) ion-selective electrodes (ISEs), the surfaces of Pt, Au, and GC electrodes were coated with 0.1, 1.0, 2.0, and 4.0 µm thick galva...

Full description

Bibliographic Details
Main Authors: Guzinski, M., Jarvis, J., Perez, F., Pendley, B., Lindner, E., De Marco, Roland, Crespo, G., Acres, R., Walker, R., Bishop, J.
Format: Journal Article
Published: American Chemical Society 2017
Online Access:http://hdl.handle.net/20.500.11937/52803
_version_ 1848759015245348864
author Guzinski, M.
Jarvis, J.
Perez, F.
Pendley, B.
Lindner, E.
De Marco, Roland
Crespo, G.
Acres, R.
Walker, R.
Bishop, J.
author_facet Guzinski, M.
Jarvis, J.
Perez, F.
Pendley, B.
Lindner, E.
De Marco, Roland
Crespo, G.
Acres, R.
Walker, R.
Bishop, J.
author_sort Guzinski, M.
building Curtin Institutional Repository
collection Online Access
description To understand the rate determining processes during the equilibration of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate-based (PEDOT(PSS)-based) solid contact (SC) ion-selective electrodes (ISEs), the surfaces of Pt, Au, and GC electrodes were coated with 0.1, 1.0, 2.0, and 4.0 µm thick galvanostatically deposited PEDOT(PSS) films. Next, potential vs time transients were recorded with these electrodes, with and without an additional potassium ion-selective membrane (ISM) coating, following their first contact with 0.1 M KCl solutions. The transients were significantly different when the multilayered sensor structures were assembled on Au or GC compared to Pt. The differences in the rate of equilibration were interpreted as a consequence of differences in the hydrophilicity of PEDOT(PSS) in contact with the substrate electrode surfaces based on X-ray photoelectron spectroscopy (XPS) and synchrotron radiation-XPS (SR-XPS) analysis of 10-100 nm thick PEDOT(PSS) films. The influence of the layer thickness of the electrochemically deposited PEDOT(PSS)-films on the hydrophilicity of these films has been documented by contact angle measurements over PEDOT(PSS)-coated Au, GC, and Pt electrode surfaces. This study demonstrates that it is possible to minimize the equilibration (conditioning) time of SC ISEs with aqueous solutions before usage by optimizing the thickness of the SC layer with a controlled ISM thickness. PEDOT(PSS)-coated Au and GC electrodes exhibit a significant negative potential drift during their equilibration in an aqueous solution. By coating the PEDOT(PSS) surface with an ISM, the negative potential drift is compensated by a positive potential drift related to the hydration of the ISM and activity changes at the PEDOT(PSS)|ISM interface. The potential drifts related to activity changes in the ISM have been determined by a novel adaptation of the "sandwich membrane" method.
first_indexed 2025-11-14T09:53:10Z
format Journal Article
id curtin-20.500.11937-52803
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:53:10Z
publishDate 2017
publisher American Chemical Society
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-528032017-09-13T15:39:04Z PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times Guzinski, M. Jarvis, J. Perez, F. Pendley, B. Lindner, E. De Marco, Roland Crespo, G. Acres, R. Walker, R. Bishop, J. To understand the rate determining processes during the equilibration of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate-based (PEDOT(PSS)-based) solid contact (SC) ion-selective electrodes (ISEs), the surfaces of Pt, Au, and GC electrodes were coated with 0.1, 1.0, 2.0, and 4.0 µm thick galvanostatically deposited PEDOT(PSS) films. Next, potential vs time transients were recorded with these electrodes, with and without an additional potassium ion-selective membrane (ISM) coating, following their first contact with 0.1 M KCl solutions. The transients were significantly different when the multilayered sensor structures were assembled on Au or GC compared to Pt. The differences in the rate of equilibration were interpreted as a consequence of differences in the hydrophilicity of PEDOT(PSS) in contact with the substrate electrode surfaces based on X-ray photoelectron spectroscopy (XPS) and synchrotron radiation-XPS (SR-XPS) analysis of 10-100 nm thick PEDOT(PSS) films. The influence of the layer thickness of the electrochemically deposited PEDOT(PSS)-films on the hydrophilicity of these films has been documented by contact angle measurements over PEDOT(PSS)-coated Au, GC, and Pt electrode surfaces. This study demonstrates that it is possible to minimize the equilibration (conditioning) time of SC ISEs with aqueous solutions before usage by optimizing the thickness of the SC layer with a controlled ISM thickness. PEDOT(PSS)-coated Au and GC electrodes exhibit a significant negative potential drift during their equilibration in an aqueous solution. By coating the PEDOT(PSS) surface with an ISM, the negative potential drift is compensated by a positive potential drift related to the hydration of the ISM and activity changes at the PEDOT(PSS)|ISM interface. The potential drifts related to activity changes in the ISM have been determined by a novel adaptation of the "sandwich membrane" method. 2017 Journal Article http://hdl.handle.net/20.500.11937/52803 10.1021/acs.analchem.6b04625 American Chemical Society restricted
spellingShingle Guzinski, M.
Jarvis, J.
Perez, F.
Pendley, B.
Lindner, E.
De Marco, Roland
Crespo, G.
Acres, R.
Walker, R.
Bishop, J.
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
title PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
title_full PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
title_fullStr PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
title_full_unstemmed PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
title_short PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
title_sort pedot(pss) as solid contact for ion-selective electrodes: the influence of the pedot(pss) film thickness on the equilibration times
url http://hdl.handle.net/20.500.11937/52803