Study of autoclaved aerated concrete masonry walls under vented gas explosions

© 2017 Elsevier LtdA total of nine full-scale in-situ tests were carried out to investigate the performances of autoclaved aerated concrete (AAC) masonry walls subjected to vented gas explosions. The testing data including overpressure time histories of vented gas explosions, displacement time histo...

Full description

Bibliographic Details
Main Authors: Li, Z., Chen, L., Fang, Q., Hao, Hong, Zhang, Y., Chen, Wensu, Xiang, H., Bao, Q.
Format: Journal Article
Published: Pergamon 2017
Online Access:http://purl.org/au-research/grants/arc/LP150100259
http://hdl.handle.net/20.500.11937/52605
_version_ 1848758967888510976
author Li, Z.
Chen, L.
Fang, Q.
Hao, Hong
Zhang, Y.
Chen, Wensu
Xiang, H.
Bao, Q.
author_facet Li, Z.
Chen, L.
Fang, Q.
Hao, Hong
Zhang, Y.
Chen, Wensu
Xiang, H.
Bao, Q.
author_sort Li, Z.
building Curtin Institutional Repository
collection Online Access
description © 2017 Elsevier LtdA total of nine full-scale in-situ tests were carried out to investigate the performances of autoclaved aerated concrete (AAC) masonry walls subjected to vented gas explosions. The testing data including overpressure time histories of vented gas explosions, displacement time histories, and damage characteristics of AAC masonry walls in each test were recorded and analysed. It was found that the responses of masonry walls mainly depend on the peak value of overpressure and couple with the time history of gas explosion loads. Typical one-way or two-way flexural mode dominates the failure of AAC walls under vented gas explosions. A detailed micro model for masonry walls was developed in LS-DYNA, incorporating material parameters that were obtained from material tests. The accuracy of numerical model in predicting the responses of masonry walls was verified with the testing data. Parametric studies were conducted to explore the influences of block strength, boundary condition and wall thickness on the performances of masonry walls. The results reveal both wall thickness and boundary condition have significant influences on the response of the masonry wall while block strength has limited effect on its performance. The testing data were compared with the analytical predictions by using design code UFC 3-340-2 and equivalent single-degree-of-freedom (SDOF) methods developed respectively by Biggs and Morison. The results indicate that these predictions on one-way specimens agree well with the testing data, while the performance of two-way specimens is overestimated by using these three methods.
first_indexed 2025-11-14T09:52:24Z
format Journal Article
id curtin-20.500.11937-52605
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:52:24Z
publishDate 2017
publisher Pergamon
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-526052023-02-02T03:24:11Z Study of autoclaved aerated concrete masonry walls under vented gas explosions Li, Z. Chen, L. Fang, Q. Hao, Hong Zhang, Y. Chen, Wensu Xiang, H. Bao, Q. © 2017 Elsevier LtdA total of nine full-scale in-situ tests were carried out to investigate the performances of autoclaved aerated concrete (AAC) masonry walls subjected to vented gas explosions. The testing data including overpressure time histories of vented gas explosions, displacement time histories, and damage characteristics of AAC masonry walls in each test were recorded and analysed. It was found that the responses of masonry walls mainly depend on the peak value of overpressure and couple with the time history of gas explosion loads. Typical one-way or two-way flexural mode dominates the failure of AAC walls under vented gas explosions. A detailed micro model for masonry walls was developed in LS-DYNA, incorporating material parameters that were obtained from material tests. The accuracy of numerical model in predicting the responses of masonry walls was verified with the testing data. Parametric studies were conducted to explore the influences of block strength, boundary condition and wall thickness on the performances of masonry walls. The results reveal both wall thickness and boundary condition have significant influences on the response of the masonry wall while block strength has limited effect on its performance. The testing data were compared with the analytical predictions by using design code UFC 3-340-2 and equivalent single-degree-of-freedom (SDOF) methods developed respectively by Biggs and Morison. The results indicate that these predictions on one-way specimens agree well with the testing data, while the performance of two-way specimens is overestimated by using these three methods. 2017 Journal Article http://hdl.handle.net/20.500.11937/52605 10.1016/j.engstruct.2017.03.033 http://purl.org/au-research/grants/arc/LP150100259 Pergamon restricted
spellingShingle Li, Z.
Chen, L.
Fang, Q.
Hao, Hong
Zhang, Y.
Chen, Wensu
Xiang, H.
Bao, Q.
Study of autoclaved aerated concrete masonry walls under vented gas explosions
title Study of autoclaved aerated concrete masonry walls under vented gas explosions
title_full Study of autoclaved aerated concrete masonry walls under vented gas explosions
title_fullStr Study of autoclaved aerated concrete masonry walls under vented gas explosions
title_full_unstemmed Study of autoclaved aerated concrete masonry walls under vented gas explosions
title_short Study of autoclaved aerated concrete masonry walls under vented gas explosions
title_sort study of autoclaved aerated concrete masonry walls under vented gas explosions
url http://purl.org/au-research/grants/arc/LP150100259
http://hdl.handle.net/20.500.11937/52605