Suppressing resonance in transformer winding under very fast transient overvoltage

This paper presents a new method for suppressing internal resonance in power transformers connected to gas insulated substation (GIS) due to very fast transient overvoltage (VFTO) in the GIS. Internal resonance within the transformer windings will take place if one of VFTO frequencies matches with t...

Full description

Bibliographic Details
Main Authors: Babaei, M., Abu-Siada, Ahmed
Format: Conference Paper
Published: 2016
Online Access:http://hdl.handle.net/20.500.11937/50715
_version_ 1848758523797700608
author Babaei, M.
Abu-Siada, Ahmed
Babaei, M.
author_facet Babaei, M.
Abu-Siada, Ahmed
Babaei, M.
author_sort Babaei, M.
building Curtin Institutional Repository
collection Online Access
description This paper presents a new method for suppressing internal resonance in power transformers connected to gas insulated substation (GIS) due to very fast transient overvoltage (VFTO) in the GIS. Internal resonance within the transformer windings will take place if one of VFTO frequencies matches with the power transformer natural frequency. In this context, the parameters affecting internal transformer resonance are investigated through the simulation of 400kV GIS connected to a 250MVA, three phase transformer and a new suppressing method for internal transformer resonances is proposed. In contrary with existing resonance suppressing approaches that call for modifications in the GIS structure, the proposed method in this paper can be employed with any existing GIS without any change in its structure.
first_indexed 2025-11-14T09:45:21Z
format Conference Paper
id curtin-20.500.11937-50715
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:45:21Z
publishDate 2016
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-507152017-09-13T15:37:43Z Suppressing resonance in transformer winding under very fast transient overvoltage Babaei, M. Abu-Siada, Ahmed Babaei, M. This paper presents a new method for suppressing internal resonance in power transformers connected to gas insulated substation (GIS) due to very fast transient overvoltage (VFTO) in the GIS. Internal resonance within the transformer windings will take place if one of VFTO frequencies matches with the power transformer natural frequency. In this context, the parameters affecting internal transformer resonance are investigated through the simulation of 400kV GIS connected to a 250MVA, three phase transformer and a new suppressing method for internal transformer resonances is proposed. In contrary with existing resonance suppressing approaches that call for modifications in the GIS structure, the proposed method in this paper can be employed with any existing GIS without any change in its structure. 2016 Conference Paper http://hdl.handle.net/20.500.11937/50715 10.1109/ISGT-Asia.2016.7796528 restricted
spellingShingle Babaei, M.
Abu-Siada, Ahmed
Babaei, M.
Suppressing resonance in transformer winding under very fast transient overvoltage
title Suppressing resonance in transformer winding under very fast transient overvoltage
title_full Suppressing resonance in transformer winding under very fast transient overvoltage
title_fullStr Suppressing resonance in transformer winding under very fast transient overvoltage
title_full_unstemmed Suppressing resonance in transformer winding under very fast transient overvoltage
title_short Suppressing resonance in transformer winding under very fast transient overvoltage
title_sort suppressing resonance in transformer winding under very fast transient overvoltage
url http://hdl.handle.net/20.500.11937/50715