Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies

Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectric t...

Full description

Bibliographic Details
Main Authors: Ghasemi, N., Zare, F., Davari, P., Vilathgamuwa, M., Ghosh, Arindam, Langton, C., Weber, P.
Format: Journal Article
Published: 2017
Online Access:http://hdl.handle.net/20.500.11937/50644
_version_ 1848758511646801920
author Ghasemi, N.
Zare, F.
Davari, P.
Vilathgamuwa, M.
Ghosh, Arindam
Langton, C.
Weber, P.
author_facet Ghasemi, N.
Zare, F.
Davari, P.
Vilathgamuwa, M.
Ghosh, Arindam
Langton, C.
Weber, P.
author_sort Ghasemi, N.
building Curtin Institutional Repository
collection Online Access
description Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectric transducer impedance has been discussed in different literatures, the trend of the nonlinearity at different frequencies with respect to excitation voltage variations has not been clearly investigated in practice. In this paper, to demonstrate how the nonlinearity behaves, a sandwich piezoceramic transducer was excited at different frequencies. Different excitation signals were generated using a linear power amplifier and a multilevel converter within a range of 30–200 V. Empirical relation was developed to express the resistance of the piezoelectric transducer as a nonlinear function of both excitation voltage and resonance frequency. The impedance measurements revealed that at higher voltage ranges, the piezoelectric transducer can be easily saturated. Also, it was shown that for the developed ultrasound system composed of two transducers (one transmitter and one receiver), the output voltage measured across receiver is a function of a voltage across the resistor in the RLC branches and is related to the resonance frequencies of the ultrasound transducer.
first_indexed 2025-11-14T09:45:09Z
format Journal Article
id curtin-20.500.11937-50644
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:45:09Z
publishDate 2017
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-506442018-03-29T09:09:36Z Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies Ghasemi, N. Zare, F. Davari, P. Vilathgamuwa, M. Ghosh, Arindam Langton, C. Weber, P. Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectric transducer impedance has been discussed in different literatures, the trend of the nonlinearity at different frequencies with respect to excitation voltage variations has not been clearly investigated in practice. In this paper, to demonstrate how the nonlinearity behaves, a sandwich piezoceramic transducer was excited at different frequencies. Different excitation signals were generated using a linear power amplifier and a multilevel converter within a range of 30–200 V. Empirical relation was developed to express the resistance of the piezoelectric transducer as a nonlinear function of both excitation voltage and resonance frequency. The impedance measurements revealed that at higher voltage ranges, the piezoelectric transducer can be easily saturated. Also, it was shown that for the developed ultrasound system composed of two transducers (one transmitter and one receiver), the output voltage measured across receiver is a function of a voltage across the resistor in the RLC branches and is related to the resonance frequencies of the ultrasound transducer. 2017 Journal Article http://hdl.handle.net/20.500.11937/50644 10.1016/j.ultras.2016.09.023 restricted
spellingShingle Ghasemi, N.
Zare, F.
Davari, P.
Vilathgamuwa, M.
Ghosh, Arindam
Langton, C.
Weber, P.
Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies
title Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies
title_full Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies
title_fullStr Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies
title_full_unstemmed Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies
title_short Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies
title_sort dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies
url http://hdl.handle.net/20.500.11937/50644