Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays

The voltammetric detection of less than 1 ppm of ammonia gas in the room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]) is demonstrated using low-cost planar electrode devices. Three commercially available planar devices were employed, a...

Full description

Bibliographic Details
Main Authors: Hussain, G., Silvester, Debbie
Format: Journal Article
Published: American Chemical Society 2016
Online Access:http://purl.org/au-research/grants/arc/LE130100121
http://hdl.handle.net/20.500.11937/50294
_version_ 1848758441393258496
author Hussain, G.
Silvester, Debbie
author_facet Hussain, G.
Silvester, Debbie
author_sort Hussain, G.
building Curtin Institutional Repository
collection Online Access
description The voltammetric detection of less than 1 ppm of ammonia gas in the room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]) is demonstrated using low-cost planar electrode devices. Three commercially available planar devices were employed, all with platinum (Pt) working electrodes: a thin-film electrode (TFE), a screen-printed electrode (SPE), and a microarray thin film electrode (MATFE), along with an "ideal" conventional Pt microdisk electrode for comparison. The microholes on the recessed MATFE were also "filled" with electrodeposited platinum, to improve radial diffusion characteristics to the microhole and generate higher current densities. Current density was lowest for the TFE and SPE surfaces (linear diffusion), higher for the MATFE (mixed radial and linear diffusion), and even higher for the filled MATFE (predominantly radial diffusion). Linear sweep voltammetry (LSV) and potential-step chronoamperometry (PSCA) at 10-100 ppm of NH3 gave linear behavior for current vs concentration. Limits of detection (LODs) were in the range of ca. 1-9 ppm, lower than the minimum exposure limit (25 ppm) for NH3. The best stability, reproducibility, and the lowest LODs were observed on the recessed and filled MATFEs. These were employed to detect lower concentrations of ammonia (0.1-2 ppm), where linear behavior was also observed, and LODs of 0.11 (recessed) and 0.02 (filled) were obtained. These are believed to be the lowest LODs (to date) reported for ammonia gas in neat ionic liquids. This is highly encouraging and suggests that RTILs and low-cost miniaturized MATFEs can be combined in amperometric sensor devices to easily and cheaply detect ammonia gas at ppb concentrations. (Graph Presented).
first_indexed 2025-11-14T09:44:02Z
format Journal Article
id curtin-20.500.11937-50294
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:44:02Z
publishDate 2016
publisher American Chemical Society
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-502942022-09-06T04:54:28Z Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays Hussain, G. Silvester, Debbie The voltammetric detection of less than 1 ppm of ammonia gas in the room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]) is demonstrated using low-cost planar electrode devices. Three commercially available planar devices were employed, all with platinum (Pt) working electrodes: a thin-film electrode (TFE), a screen-printed electrode (SPE), and a microarray thin film electrode (MATFE), along with an "ideal" conventional Pt microdisk electrode for comparison. The microholes on the recessed MATFE were also "filled" with electrodeposited platinum, to improve radial diffusion characteristics to the microhole and generate higher current densities. Current density was lowest for the TFE and SPE surfaces (linear diffusion), higher for the MATFE (mixed radial and linear diffusion), and even higher for the filled MATFE (predominantly radial diffusion). Linear sweep voltammetry (LSV) and potential-step chronoamperometry (PSCA) at 10-100 ppm of NH3 gave linear behavior for current vs concentration. Limits of detection (LODs) were in the range of ca. 1-9 ppm, lower than the minimum exposure limit (25 ppm) for NH3. The best stability, reproducibility, and the lowest LODs were observed on the recessed and filled MATFEs. These were employed to detect lower concentrations of ammonia (0.1-2 ppm), where linear behavior was also observed, and LODs of 0.11 (recessed) and 0.02 (filled) were obtained. These are believed to be the lowest LODs (to date) reported for ammonia gas in neat ionic liquids. This is highly encouraging and suggests that RTILs and low-cost miniaturized MATFEs can be combined in amperometric sensor devices to easily and cheaply detect ammonia gas at ppb concentrations. (Graph Presented). 2016 Journal Article http://hdl.handle.net/20.500.11937/50294 10.1021/acs.analchem.6b03824 http://purl.org/au-research/grants/arc/LE130100121 American Chemical Society fulltext
spellingShingle Hussain, G.
Silvester, Debbie
Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays
title Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays
title_full Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays
title_fullStr Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays
title_full_unstemmed Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays
title_short Detection of sub-ppm Concentrations of Ammonia in an Ionic Liquid: Enhanced Current Density Using "Filled" Recessed Microarrays
title_sort detection of sub-ppm concentrations of ammonia in an ionic liquid: enhanced current density using "filled" recessed microarrays
url http://purl.org/au-research/grants/arc/LE130100121
http://hdl.handle.net/20.500.11937/50294