A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations

This thesis investigates the feasibility of a new method to prevent internal resonance in transformers connected to gas insulated substation due to very fast transient overvoltage in the GIS. The possibility of utilizing a cost effective RC surge suppressor to prevent internal transformer resonance...

Full description

Bibliographic Details
Main Author: Babaeilaktarashani, Mehdi
Format: Thesis
Published: Curtin University 2016
Online Access:http://hdl.handle.net/20.500.11937/48827
_version_ 1848758117124276224
author Babaeilaktarashani, Mehdi
author_facet Babaeilaktarashani, Mehdi
author_sort Babaeilaktarashani, Mehdi
building Curtin Institutional Repository
collection Online Access
description This thesis investigates the feasibility of a new method to prevent internal resonance in transformers connected to gas insulated substation due to very fast transient overvoltage in the GIS. The possibility of utilizing a cost effective RC surge suppressor to prevent internal transformer resonance is analyzed and the optimum suppressor in terms of capability to suppress high risk frequencies of VFTO is proposed. In comparison with other existing methods, the proposed method is a simple and cost effective method.
first_indexed 2025-11-14T09:38:53Z
format Thesis
id curtin-20.500.11937-48827
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:38:53Z
publishDate 2016
publisher Curtin University
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-488272017-03-03T07:53:01Z A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations Babaeilaktarashani, Mehdi This thesis investigates the feasibility of a new method to prevent internal resonance in transformers connected to gas insulated substation due to very fast transient overvoltage in the GIS. The possibility of utilizing a cost effective RC surge suppressor to prevent internal transformer resonance is analyzed and the optimum suppressor in terms of capability to suppress high risk frequencies of VFTO is proposed. In comparison with other existing methods, the proposed method is a simple and cost effective method. 2016 Thesis http://hdl.handle.net/20.500.11937/48827 Curtin University fulltext
spellingShingle Babaeilaktarashani, Mehdi
A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations
title A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations
title_full A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations
title_fullStr A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations
title_full_unstemmed A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations
title_short A New Cost Effective Approach to Suppress Very Fast Transients on Power Transformers Connected to Gas Insulated Substations
title_sort new cost effective approach to suppress very fast transients on power transformers connected to gas insulated substations
url http://hdl.handle.net/20.500.11937/48827