Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry

Strict criteria have been established for measurement of basal metabolic rate and standard evaporative water loss to ensure that data can be compared intra‐ and interspecifically. However, data‐sampling regimes vary, from essentially continuous sampling to interrupted (switching) systems with data r...

Full description

Bibliographic Details
Main Authors: Cooper, Christine, Withers, P.
Format: Journal Article
Published: 2010
Online Access:http://hdl.handle.net/20.500.11937/47821
_version_ 1848757940341702656
author Cooper, Christine
Withers, P.
author_facet Cooper, Christine
Withers, P.
author_sort Cooper, Christine
building Curtin Institutional Repository
collection Online Access
description Strict criteria have been established for measurement of basal metabolic rate and standard evaporative water loss to ensure that data can be compared intra‐ and interspecifically. However, data‐sampling regimes vary, from essentially continuous sampling to interrupted (switching) systems with data recorded periodically at more widely spaced intervals. Here we compare one continuous and three interrupted sampling regimes to determine whether sampling regime has a significant effect on estimation of basal metabolic rate or standard evaporative water loss. Compared to continuous 20‐s sampling averaged over 20 min, sampling every 6 min and averaging over 60 min overestimated basal metabolic rate and evaporative water loss, sampling every 3 min and averaging over 21 min underestimated basal metabolic rate, and sampling every 12 min and averaging over 36 min showed no difference in estimates. Increasing the period over which the minimum mean was calculated significantly increased estimates of physiological variables. Reducing the frequency of sampling from 20 s to a longer interval of 3, 6, or 12 min underestimated basal metabolic rate but not evaporative water loss. This indicates that sampling frequency per se influences estimates of basal metabolic rate and that differences are not just an artifact of differences in the period over which the mean is calculated. Sampling regime can have a highly significant influence on estimation of standard physiological variables, although the actual differences between sampling regimes were generally small (usually <5%). Although continuous sampling is the preferred sampling regime for open‐flow respirometry studies, if time and cost are prohibitive, then use of an appropriate switching system will result in smaller errors than measuring individuals continuously for shorter periods.
first_indexed 2025-11-14T09:36:04Z
format Journal Article
id curtin-20.500.11937-47821
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:36:04Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-478212019-05-17T03:19:55Z Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry Cooper, Christine Withers, P. Strict criteria have been established for measurement of basal metabolic rate and standard evaporative water loss to ensure that data can be compared intra‐ and interspecifically. However, data‐sampling regimes vary, from essentially continuous sampling to interrupted (switching) systems with data recorded periodically at more widely spaced intervals. Here we compare one continuous and three interrupted sampling regimes to determine whether sampling regime has a significant effect on estimation of basal metabolic rate or standard evaporative water loss. Compared to continuous 20‐s sampling averaged over 20 min, sampling every 6 min and averaging over 60 min overestimated basal metabolic rate and evaporative water loss, sampling every 3 min and averaging over 21 min underestimated basal metabolic rate, and sampling every 12 min and averaging over 36 min showed no difference in estimates. Increasing the period over which the minimum mean was calculated significantly increased estimates of physiological variables. Reducing the frequency of sampling from 20 s to a longer interval of 3, 6, or 12 min underestimated basal metabolic rate but not evaporative water loss. This indicates that sampling frequency per se influences estimates of basal metabolic rate and that differences are not just an artifact of differences in the period over which the mean is calculated. Sampling regime can have a highly significant influence on estimation of standard physiological variables, although the actual differences between sampling regimes were generally small (usually <5%). Although continuous sampling is the preferred sampling regime for open‐flow respirometry studies, if time and cost are prohibitive, then use of an appropriate switching system will result in smaller errors than measuring individuals continuously for shorter periods. 2010 Journal Article http://hdl.handle.net/20.500.11937/47821 10.1086/605612 fulltext
spellingShingle Cooper, Christine
Withers, P.
Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry
title Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry
title_full Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry
title_fullStr Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry
title_full_unstemmed Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry
title_short Effect of Sampling Regime on Estimation of Basal Metabolic Rate and Standard Evaporative Water Loss Using Flow-Through Respirometry
title_sort effect of sampling regime on estimation of basal metabolic rate and standard evaporative water loss using flow-through respirometry
url http://hdl.handle.net/20.500.11937/47821