Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings

Many materials are available for retrofitting masonry infill walls to resist explosion loads. Selection of the most suitable material is essential for optimal performance and cost. In this study, a series of trials were conducted in a specially designed test setup to determine and compare the perfor...

Full description

Bibliographic Details
Main Authors: Chen, L., Fang, Q., Fan, J., Zhang, Y., Hao, Hong, Liu, J.
Format: Journal Article
Published: Multi-Science Publishing 2014
Online Access:http://hdl.handle.net/20.500.11937/47811
_version_ 1848757937171857408
author Chen, L.
Fang, Q.
Fan, J.
Zhang, Y.
Hao, Hong
Liu, J.
author_facet Chen, L.
Fang, Q.
Fan, J.
Zhang, Y.
Hao, Hong
Liu, J.
author_sort Chen, L.
building Curtin Institutional Repository
collection Online Access
description Many materials are available for retrofitting masonry infill walls to resist explosion loads. Selection of the most suitable material is essential for optimal performance and cost. In this study, a series of trials were conducted in a specially designed test setup to determine and compare the performances of 1/2-scale masonry infill walls retrofitted with carbon fibre-reinforced polymer strips, steel wire mesh and laminated steel bars, respectively, as well as an unreinforced masonry wall, subjected to blast loads. High fidelity FE models with detail modelling of brick, mortar and retrofitting materials are also developed in LS-DYNA to simulate the blast tests. The accuracy of the FE models in predicting the field blast tests is verified with the test data. The calibrated FE models are used to perform intensive numerical simulations to investigate the effectiveness of various retrofitting measures. The displacement response, failure mode, level of damage and fragmentation from both the field blasting tests and numerical simulations are compared and used to assess the effectiveness of the retrofitting measures. The results demonstrate that the URM retrofitted with steel mesh performed the best among the three retrofitting measures in blast loading resistance, the wall retrofitted with closely spaced CFRP strips performed slightly better than that with steel bars.
first_indexed 2025-11-14T09:36:01Z
format Journal Article
id curtin-20.500.11937-47811
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:36:01Z
publishDate 2014
publisher Multi-Science Publishing
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-478112017-09-13T14:19:01Z Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings Chen, L. Fang, Q. Fan, J. Zhang, Y. Hao, Hong Liu, J. Many materials are available for retrofitting masonry infill walls to resist explosion loads. Selection of the most suitable material is essential for optimal performance and cost. In this study, a series of trials were conducted in a specially designed test setup to determine and compare the performances of 1/2-scale masonry infill walls retrofitted with carbon fibre-reinforced polymer strips, steel wire mesh and laminated steel bars, respectively, as well as an unreinforced masonry wall, subjected to blast loads. High fidelity FE models with detail modelling of brick, mortar and retrofitting materials are also developed in LS-DYNA to simulate the blast tests. The accuracy of the FE models in predicting the field blast tests is verified with the test data. The calibrated FE models are used to perform intensive numerical simulations to investigate the effectiveness of various retrofitting measures. The displacement response, failure mode, level of damage and fragmentation from both the field blasting tests and numerical simulations are compared and used to assess the effectiveness of the retrofitting measures. The results demonstrate that the URM retrofitted with steel mesh performed the best among the three retrofitting measures in blast loading resistance, the wall retrofitted with closely spaced CFRP strips performed slightly better than that with steel bars. 2014 Journal Article http://hdl.handle.net/20.500.11937/47811 10.1260/1369-4332.17.6.817 Multi-Science Publishing restricted
spellingShingle Chen, L.
Fang, Q.
Fan, J.
Zhang, Y.
Hao, Hong
Liu, J.
Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings
title Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings
title_full Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings
title_fullStr Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings
title_full_unstemmed Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings
title_short Responses of Masonry Infill Walls Retrofitted with CFRP, Steel Wire Mesh and Laminated Bars to Blast Loadings
title_sort responses of masonry infill walls retrofitted with cfrp, steel wire mesh and laminated bars to blast loadings
url http://hdl.handle.net/20.500.11937/47811