Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure

In doubly fed induction generator (DFIG) based wind energy conversion systems (WECS), the DFIG is interfaced to the AC network through grid side voltage source converter (GSC) and rotor side voltage source converter (RSC). The RSC and the GSC are coupled by a DC-link capacitor. The capacitor is used...

Full description

Bibliographic Details
Main Authors: Abdou, A., Abu-Siada, Ahmed, Pota, H.
Other Authors: Nabil Abbasy
Format: Conference Paper
Published: Faculty of Engineering, Alexandria University 2012
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/4603
_version_ 1848744563005456384
author Abdou, A.
Abu-Siada, Ahmed
Pota, H.
author2 Nabil Abbasy
author_facet Nabil Abbasy
Abdou, A.
Abu-Siada, Ahmed
Pota, H.
author_sort Abdou, A.
building Curtin Institutional Repository
collection Online Access
description In doubly fed induction generator (DFIG) based wind energy conversion systems (WECS), the DFIG is interfaced to the AC network through grid side voltage source converter (GSC) and rotor side voltage source converter (RSC). The RSC and the GSC are coupled by a DC-link capacitor. The capacitor is used as an energy storage device and is controlled to keep the voltage fluctuation across the DC-link within permissible limits. The sensitivity of DFIG to external faults has motivated researchers to investigate the impact of various grid disturbances such as voltage sag and short circuit faults on the low voltage ride through (LVRT) capability of the DFIG. There is however, a little attention in the literature has been given to investigate the impact of internal faults on the LVRT of the DFIG-based WECS. In this paper, the impact of a DC-link capacitor short circuit fault on the dynamic performance of DFIG-based WECS is investigated. A proper voltage controller for a STATCOM to mitigate the effects of such failure on the voltage profile at the point of common coupling (PCC) is proposed. To examine the robustness of the proposed controller, DFIG compliance with various recently released LVRT grid codes under DC-link failure with and without the STATCOM is investigated and compared. Simulation results indicate that fault has a severe impact on the DFIG voltage profile and the proposed controller is capable of bringing the voltage profile at the PCC to the nominal steady state level.
first_indexed 2025-11-14T06:03:27Z
format Conference Paper
id curtin-20.500.11937-4603
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:03:27Z
publishDate 2012
publisher Faculty of Engineering, Alexandria University
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-46032017-01-30T10:40:16Z Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure Abdou, A. Abu-Siada, Ahmed Pota, H. Nabil Abbasy LVRT DFIG GSC STATCOM grid codes RSC In doubly fed induction generator (DFIG) based wind energy conversion systems (WECS), the DFIG is interfaced to the AC network through grid side voltage source converter (GSC) and rotor side voltage source converter (RSC). The RSC and the GSC are coupled by a DC-link capacitor. The capacitor is used as an energy storage device and is controlled to keep the voltage fluctuation across the DC-link within permissible limits. The sensitivity of DFIG to external faults has motivated researchers to investigate the impact of various grid disturbances such as voltage sag and short circuit faults on the low voltage ride through (LVRT) capability of the DFIG. There is however, a little attention in the literature has been given to investigate the impact of internal faults on the LVRT of the DFIG-based WECS. In this paper, the impact of a DC-link capacitor short circuit fault on the dynamic performance of DFIG-based WECS is investigated. A proper voltage controller for a STATCOM to mitigate the effects of such failure on the voltage profile at the point of common coupling (PCC) is proposed. To examine the robustness of the proposed controller, DFIG compliance with various recently released LVRT grid codes under DC-link failure with and without the STATCOM is investigated and compared. Simulation results indicate that fault has a severe impact on the DFIG voltage profile and the proposed controller is capable of bringing the voltage profile at the PCC to the nominal steady state level. 2012 Conference Paper http://hdl.handle.net/20.500.11937/4603 Faculty of Engineering, Alexandria University restricted
spellingShingle LVRT
DFIG
GSC
STATCOM
grid codes
RSC
Abdou, A.
Abu-Siada, Ahmed
Pota, H.
Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure
title Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure
title_full Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure
title_fullStr Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure
title_full_unstemmed Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure
title_short Application of STATCOM to improve the LVRT of DFIG during DC-link capacitor failure
title_sort application of statcom to improve the lvrt of dfig during dc-link capacitor failure
topic LVRT
DFIG
GSC
STATCOM
grid codes
RSC
url http://hdl.handle.net/20.500.11937/4603