Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode.

Voltammetric behavior at gold electrodes in aqueous media is known to be strongly dependent on electrode polishing and history. In this study, an electrode array consisting of 100 nominally identical and individually addressable gold disks electrodes, each with a radius of 127 m, has been fabricated...

Full description

Bibliographic Details
Main Authors: Lee, C., Tan, Yong-jun, Bond, A.
Format: Journal Article
Published: American Chemical Society ACS 2008
Online Access:http://hdl.handle.net/20.500.11937/43995
_version_ 1848756870685130752
author Lee, C.
Tan, Yong-jun
Bond, A.
author_facet Lee, C.
Tan, Yong-jun
Bond, A.
author_sort Lee, C.
building Curtin Institutional Repository
collection Online Access
description Voltammetric behavior at gold electrodes in aqueous media is known to be strongly dependent on electrode polishing and history. In this study, an electrode array consisting of 100 nominally identical and individually addressable gold disks electrodes, each with a radius of 127 m, has been fabricated. The ability to analyze both individual electrode and total array performance enables microscopic aspects of the overall voltammetric response arising from variable levels of inhomogeneity in each electrode to be identified. The array configuration was initially employed with the reversible and hence relatively surface insensitive [Ru(NH3)6]3+/2+ reaction and then with the more highly surface sensitive quasi-reversible [Fe(CN)6]3-/4- process. In both these cases, the reactants and products are solution soluble and, at a scan rate of 50 mV s-1, each electrode in the array is assumed to behave independently, since no evidence of overlapping of the diffusion layers was detected. As would be expected, the variability of the individual electrodes responses was significantly larger than found for the summed electrode behavior. In the case of cytochrome c voltammetry at a 4,4'-dipyridyl disulfide modified electrode, a far greater dependence on electrode history and electrode heterogeneity was detected. In this case, voltammograms derived from individual electrodes in the gold array electrode exhibit shape variations ranging from peak to sigmoidal. However, again the total response was always found to be well-defined. This voltammetry is consistent with a microscopic model of heterogeneity where some parts of each chemically modified electrode surface are electroactive while other parts are less active. The findings are consistent with the common existence of electrode heterogeneity in cyclic voltammetric responses at gold electrodes, that are normally difficult to detect, but fundamentally important, as electrode nonuniformity can give rise to subtle forms of kinetic and other forms of dispersion.
first_indexed 2025-11-14T09:19:04Z
format Journal Article
id curtin-20.500.11937-43995
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:19:04Z
publishDate 2008
publisher American Chemical Society ACS
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-439952017-09-13T15:58:25Z Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode. Lee, C. Tan, Yong-jun Bond, A. Voltammetric behavior at gold electrodes in aqueous media is known to be strongly dependent on electrode polishing and history. In this study, an electrode array consisting of 100 nominally identical and individually addressable gold disks electrodes, each with a radius of 127 m, has been fabricated. The ability to analyze both individual electrode and total array performance enables microscopic aspects of the overall voltammetric response arising from variable levels of inhomogeneity in each electrode to be identified. The array configuration was initially employed with the reversible and hence relatively surface insensitive [Ru(NH3)6]3+/2+ reaction and then with the more highly surface sensitive quasi-reversible [Fe(CN)6]3-/4- process. In both these cases, the reactants and products are solution soluble and, at a scan rate of 50 mV s-1, each electrode in the array is assumed to behave independently, since no evidence of overlapping of the diffusion layers was detected. As would be expected, the variability of the individual electrodes responses was significantly larger than found for the summed electrode behavior. In the case of cytochrome c voltammetry at a 4,4'-dipyridyl disulfide modified electrode, a far greater dependence on electrode history and electrode heterogeneity was detected. In this case, voltammograms derived from individual electrodes in the gold array electrode exhibit shape variations ranging from peak to sigmoidal. However, again the total response was always found to be well-defined. This voltammetry is consistent with a microscopic model of heterogeneity where some parts of each chemically modified electrode surface are electroactive while other parts are less active. The findings are consistent with the common existence of electrode heterogeneity in cyclic voltammetric responses at gold electrodes, that are normally difficult to detect, but fundamentally important, as electrode nonuniformity can give rise to subtle forms of kinetic and other forms of dispersion. 2008 Journal Article http://hdl.handle.net/20.500.11937/43995 10.1021/ac8002227 American Chemical Society ACS restricted
spellingShingle Lee, C.
Tan, Yong-jun
Bond, A.
Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode.
title Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode.
title_full Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode.
title_fullStr Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode.
title_full_unstemmed Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode.
title_short Identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually Addressable Gold Array Electrode.
title_sort identification of surface heterogeneity effects in cyclic voltammograms derived from analysis of an individually addressable gold array electrode.
url http://hdl.handle.net/20.500.11937/43995