Time domain analysis of a synchronous generator in distorted power systems

Calculating the synchronous generator steady state operating conditions and load angle is essential for power system studies. Time and space harmonics can cause variations on power system operation. This paper investigates the impact of time and space harmonics on the synchronous generator inductanc...

Full description

Bibliographic Details
Main Authors: Ladjavardi, Marjan, Masoum, Mohammed, Islam, Syed
Other Authors: Not known
Format: Conference Paper
Published: Curtin University of Technoklogy 2007
Online Access:http://hdl.handle.net/20.500.11937/43897
_version_ 1848756840832172032
author Ladjavardi, Marjan
Masoum, Mohammed
Islam, Syed
author2 Not known
author_facet Not known
Ladjavardi, Marjan
Masoum, Mohammed
Islam, Syed
author_sort Ladjavardi, Marjan
building Curtin Institutional Repository
collection Online Access
description Calculating the synchronous generator steady state operating conditions and load angle is essential for power system studies. Time and space harmonics can cause variations on power system operation. This paper investigates the impact of time and space harmonics on the synchronous generator inductances, rotor currents, produced stator fluxes and voltages, electromagnetic torque and the steady state rotor angle. Harmonic Domain and abc-frame of reference is used for nonlinear modeling of synchronous generator. The instantaneous electromagnetic torque is calculated using rotational voltage component. Simulation results show that the presence of harmonics can affect the synchronous generator steady state operation and damper windings have considerable impact on the produces stator fluxes and voltages in the presence of harmonics. Matlab/Simulink software and Simpowersystem toolbox are used for the simulation in time domain.
first_indexed 2025-11-14T09:18:36Z
format Conference Paper
id curtin-20.500.11937-43897
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:18:36Z
publishDate 2007
publisher Curtin University of Technoklogy
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-438972017-01-30T15:10:48Z Time domain analysis of a synchronous generator in distorted power systems Ladjavardi, Marjan Masoum, Mohammed Islam, Syed Not known Calculating the synchronous generator steady state operating conditions and load angle is essential for power system studies. Time and space harmonics can cause variations on power system operation. This paper investigates the impact of time and space harmonics on the synchronous generator inductances, rotor currents, produced stator fluxes and voltages, electromagnetic torque and the steady state rotor angle. Harmonic Domain and abc-frame of reference is used for nonlinear modeling of synchronous generator. The instantaneous electromagnetic torque is calculated using rotational voltage component. Simulation results show that the presence of harmonics can affect the synchronous generator steady state operation and damper windings have considerable impact on the produces stator fluxes and voltages in the presence of harmonics. Matlab/Simulink software and Simpowersystem toolbox are used for the simulation in time domain. 2007 Conference Paper http://hdl.handle.net/20.500.11937/43897 Curtin University of Technoklogy fulltext
spellingShingle Ladjavardi, Marjan
Masoum, Mohammed
Islam, Syed
Time domain analysis of a synchronous generator in distorted power systems
title Time domain analysis of a synchronous generator in distorted power systems
title_full Time domain analysis of a synchronous generator in distorted power systems
title_fullStr Time domain analysis of a synchronous generator in distorted power systems
title_full_unstemmed Time domain analysis of a synchronous generator in distorted power systems
title_short Time domain analysis of a synchronous generator in distorted power systems
title_sort time domain analysis of a synchronous generator in distorted power systems
url http://hdl.handle.net/20.500.11937/43897