Ion-Transfer Voltammetric Behavior of Propranolol at Nanoscale Liquid-Liquid Interface Arrays
In this work, the ion-transfer voltammetric detection of the protonated β-blocker propranolol was explored at arrays of nanoscale interfaces between two immiscible electrolyte solutions (ITIES). Silicon nitride nanoporous membranes with 400 pores in a hexagonal arrangement, with either 50 or 17 nm r...
| Main Authors: | Liu, Yang, Strutwolf, J., Arrigan, Damien |
|---|---|
| Format: | Journal Article |
| Published: |
American Chemical Society
2015
|
| Online Access: | http://purl.org/au-research/grants/arc/DP130102040 http://hdl.handle.net/20.500.11937/42811 |
Similar Items
Ion-Transfer Voltammetric Determination of the B-Blocker Propranolol in a Physiological Matrix at Silicon Membrane-Based Liquid/Liquid Microinterface Arrays
by: Collins, C., et al.
Published: (2009)
by: Collins, C., et al.
Published: (2009)
Ion-Transfer Voltammetric Behavior of Protein Digests at Liquid|Liquid Interfaces
by: Herzog, G., et al.
Published: (2010)
by: Herzog, G., et al.
Published: (2010)
Chronoamperometric response at nanoscale liquid–liquid interface arrays
by: Sairi, M., et al.
Published: (2013)
by: Sairi, M., et al.
Published: (2013)
Electrochemical behaviour and voltammetric sensitivity at arrays of nanoscale interfaces between immiscible liquids
by: Rimboud, Mickael, et al.
Published: (2011)
by: Rimboud, Mickael, et al.
Published: (2011)
Optimisation of the conditions for stripping voltammetric analysis at liquid-liquid interfaces supported at micropore arrays: a computational simulation
by: Strutwolf, J., et al.
Published: (2010)
by: Strutwolf, J., et al.
Published: (2010)
Achievement of diffusional independence at nanoscale liquid-liquid interfaces within arrays
by: Liu, Yang, et al.
Published: (2015)
by: Liu, Yang, et al.
Published: (2015)
Electrochemical ion transfer across liquid/liquid interfaces confined within solid-state micropore arrays – simulations and experiments
by: Strutwolf, J., et al.
Published: (2009)
by: Strutwolf, J., et al.
Published: (2009)
Serum-protein effects on the detection of the B-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
by: Collins, C., et al.
Published: (2010)
by: Collins, C., et al.
Published: (2010)
Electroanalytical Ventures at Nanoscale Interfaces Between Immiscible Liquids
by: Arrigan, Damien, et al.
Published: (2016)
by: Arrigan, Damien, et al.
Published: (2016)
Enhanced Electroanalytical Sensitivity via Interface Miniaturisation: Ion Transfer Voltammetry at an Array of Nanometre Liquid–Liquid Interfaces
by: Scanlon, M., et al.
Published: (2011)
by: Scanlon, M., et al.
Published: (2011)
Sensing via Voltammetric Ion-Transfer at an Aqueous-Organogel Micro-Interface Array
by: Herzog, G., et al.
Published: (2011)
by: Herzog, G., et al.
Published: (2011)
The performance of differential pulse stripping voltammetry at micro-liquid-liquid interface arrays
by: Strutwolf, J., et al.
Published: (2010)
by: Strutwolf, J., et al.
Published: (2010)
Ion-transfer voltammetry at silicon membrane-based arrays of micro-liquid–liquid interfaces
by: Zazpe, R., et al.
Published: (2007)
by: Zazpe, R., et al.
Published: (2007)
Voltammetric behaviour of biological macromolecules at arrays of aqueous|organogel micro-interfaces
by: Scanlon, M., et al.
Published: (2010)
by: Scanlon, M., et al.
Published: (2010)
Interactions of proteins with small ionised molecules: electrochemical adsorption and facilitated ion transfer voltammetry of haemoglobin at the liquid|liquid interface
by: Herzog, G., et al.
Published: (2009)
by: Herzog, G., et al.
Published: (2009)
Flow-injection amperometry at microfabricated silicon-based μ-liquid–liquid interface arrays
by: Scanlon, M., et al.
Published: (2010)
by: Scanlon, M., et al.
Published: (2010)
Finite-element simulations of the influence of pore wall adsorption on cyclic voltammetry of ion transfer across a liquid–liquid interface formed at a micropore
by: Ellis, J., et al.
Published: (2012)
by: Ellis, J., et al.
Published: (2012)
Assessment of ion transfer amperometry at liquid–liquid interfaces for detection in CE
by: Sisk, G., et al.
Published: (2009)
by: Sisk, G., et al.
Published: (2009)
Electrochemical Characterisation of Nanoscale Liquid | Liquid Interfaces Located at Focused Ion Beam-Milled Silicon Nitride Membranes
by: Sairi, M., et al.
Published: (2015)
by: Sairi, M., et al.
Published: (2015)
Ion-transfer electrochemistry at arrays of nanoscale interfaces between two immiscible electrolyte solutions arranged in hexagonal format
by: Liu, Yang, et al.
Published: (2022)
by: Liu, Yang, et al.
Published: (2022)
Electrochemical detection of ractopamine at arrays of micro-liquid | liquid interfaces
by: Sairi, M., et al.
Published: (2015)
by: Sairi, M., et al.
Published: (2015)
Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
by: O'Sullivan, S., et al.
Published: (2012)
by: O'Sullivan, S., et al.
Published: (2012)
Paper-Based System for Ion Transfer Across the Liquid-Liquid Interface
by: Podrazka, M., et al.
Published: (2018)
by: Podrazka, M., et al.
Published: (2018)
Voltammetry of proteins at liquid-liquid interfaces
by: Arrigan, Damien
Published: (2013)
by: Arrigan, Damien
Published: (2013)
Array of water|room temperature ionic liquid micro-interfaces
by: Silvester, Debbie, et al.
Published: (2011)
by: Silvester, Debbie, et al.
Published: (2011)
Void-Assisted Ion-Paired Proton Transfer at Water-Ionic Liquid Interfaces.
by: Alvarez de Eulate, E., et al.
Published: (2015)
by: Alvarez de Eulate, E., et al.
Published: (2015)
Chapter 9: Amperometric ion sensing approaches at liquid/liquid interfaces for inorganic, organic and biological ions
by: Lee, H., et al.
Published: (2016)
by: Lee, H., et al.
Published: (2016)
Macromolecular sensing at the liquid-liquid interface
by: Herzog, G., et al.
Published: (2011)
by: Herzog, G., et al.
Published: (2011)
An Electrochemical Sensing Platform Based on Liquid-Liquid Microinterface Arrays Formed in Laser-Ablated Glass Membranes
by: Alvarez De Eulate, Eva, et al.
Published: (2016)
by: Alvarez De Eulate, Eva, et al.
Published: (2016)
Electrochemical detection of dopamine using arrays of liquid–liquid micro-interfaces created withinmicromachined silicon membranes
by: Berduque, A., et al.
Published: (2008)
by: Berduque, A., et al.
Published: (2008)
Stripping voltammetric detection of insulin at liquid–liquid microinterfaces in the presence of bovine albumin
by: O'Sullivan, S., et al.
Published: (2013)
by: O'Sullivan, S., et al.
Published: (2013)
Electrochemical behaviour of haemoglobin at the liquid/liquid interface
by: Herzog, G., et al.
Published: (2008)
by: Herzog, G., et al.
Published: (2008)
Haemoglobin unfolding studies at the liquid-liquid interface
by: Herzog, G., et al.
Published: (2011)
by: Herzog, G., et al.
Published: (2011)
Electrochemical Study of Insulin at the Polarized Liquid-Liquid Interface
by: Kivlehan, F., et al.
Published: (2008)
by: Kivlehan, F., et al.
Published: (2008)
The sloped limiting current region during ion transfer at arrays of nanointerfaces between immiscible electrolyte solutions
by: Rimboud, Mickaël, et al.
Published: (2024)
by: Rimboud, Mickaël, et al.
Published: (2024)
Electrochemical behaviour of denatured haemoglobin at the liquid|liquid interface
by: Herzog, G., et al.
Published: (2010)
by: Herzog, G., et al.
Published: (2010)
Bioanalytical Applications of Electrochemistry at Liquid-Liquid Microinterfaces
by: Arrigan, Damien, et al.
Published: (2013)
by: Arrigan, Damien, et al.
Published: (2013)
Detection of food additives by voltammetry at the liquid-liquid interface
by: Herzog, G., et al.
Published: (2008)
by: Herzog, G., et al.
Published: (2008)
Detection of Prostate Specific Membrane Antigen at Picomolar Levels Using Biocatalysis Coupled to Assisted Ion Transfer Voltammetry at a Liquid-Organogel Microinterface Array
by: Akter, R., et al.
Published: (2016)
by: Akter, R., et al.
Published: (2016)
Electrochemical Detection of Oligopeptides at Silicon-Fabricated Micro-Liquid|Liquid Interfaces
by: Scanlon, M., et al.
Published: (2008)
by: Scanlon, M., et al.
Published: (2008)
Similar Items
-
Ion-Transfer Voltammetric Determination of the B-Blocker Propranolol in a Physiological Matrix at Silicon Membrane-Based Liquid/Liquid Microinterface Arrays
by: Collins, C., et al.
Published: (2009) -
Ion-Transfer Voltammetric Behavior of Protein Digests at Liquid|Liquid Interfaces
by: Herzog, G., et al.
Published: (2010) -
Chronoamperometric response at nanoscale liquid–liquid interface arrays
by: Sairi, M., et al.
Published: (2013) -
Electrochemical behaviour and voltammetric sensitivity at arrays of nanoscale interfaces between immiscible liquids
by: Rimboud, Mickael, et al.
Published: (2011) -
Optimisation of the conditions for stripping voltammetric analysis at liquid-liquid interfaces supported at micropore arrays: a computational simulation
by: Strutwolf, J., et al.
Published: (2010)