Fault isolation in distributed generation connected distribution networks

Protection of a distribution network in the presence of distributed generators (DGs) using overcurrent relays is a challenging task because of the changes in fault current levels and reverse power flow. Specifically, in the presence of current limited converter interfaced DGs, overcurrent relays may...

Full description

Bibliographic Details
Main Authors: Dewadasa, M., Ghosh, Arindam, Ledwich, G., Wishart, M.
Format: Journal Article
Published: The Institution of Engineering and Technology 2011
Online Access:http://hdl.handle.net/20.500.11937/4239
_version_ 1848744459741691904
author Dewadasa, M.
Ghosh, Arindam
Ledwich, G.
Wishart, M.
author_facet Dewadasa, M.
Ghosh, Arindam
Ledwich, G.
Wishart, M.
author_sort Dewadasa, M.
building Curtin Institutional Repository
collection Online Access
description Protection of a distribution network in the presence of distributed generators (DGs) using overcurrent relays is a challenging task because of the changes in fault current levels and reverse power flow. Specifically, in the presence of current limited converter interfaced DGs, overcurrent relays may fail to isolate the faulted section either in grid connected or islanded mode of operation. In this study, a new inverse-type relay is presented to protect a distribution network, which may have several DG connections. The new relay characteristic is designed based on the measured admittance of the protected line. The relay is capable of detecting faults under changing fault current levels. The relay performance is evaluated using PSCAD simulation and laboratory experiments.
first_indexed 2025-11-14T06:01:48Z
format Journal Article
id curtin-20.500.11937-4239
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:01:48Z
publishDate 2011
publisher The Institution of Engineering and Technology
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-42392017-02-28T01:28:39Z Fault isolation in distributed generation connected distribution networks Dewadasa, M. Ghosh, Arindam Ledwich, G. Wishart, M. Protection of a distribution network in the presence of distributed generators (DGs) using overcurrent relays is a challenging task because of the changes in fault current levels and reverse power flow. Specifically, in the presence of current limited converter interfaced DGs, overcurrent relays may fail to isolate the faulted section either in grid connected or islanded mode of operation. In this study, a new inverse-type relay is presented to protect a distribution network, which may have several DG connections. The new relay characteristic is designed based on the measured admittance of the protected line. The relay is capable of detecting faults under changing fault current levels. The relay performance is evaluated using PSCAD simulation and laboratory experiments. 2011 Journal Article http://hdl.handle.net/20.500.11937/4239 The Institution of Engineering and Technology restricted
spellingShingle Dewadasa, M.
Ghosh, Arindam
Ledwich, G.
Wishart, M.
Fault isolation in distributed generation connected distribution networks
title Fault isolation in distributed generation connected distribution networks
title_full Fault isolation in distributed generation connected distribution networks
title_fullStr Fault isolation in distributed generation connected distribution networks
title_full_unstemmed Fault isolation in distributed generation connected distribution networks
title_short Fault isolation in distributed generation connected distribution networks
title_sort fault isolation in distributed generation connected distribution networks
url http://hdl.handle.net/20.500.11937/4239