Local site effect on seismic response of coupled transmission tower-line system

The collapses of transmission towers in large earthquakes were partially caused by the pulling forces from the transmission lines generated from out-of-phase responses of the adjacent towers owing to nonuniform ground motions. A three-dimensional finite element model of transmission tower-line syste...

Full description

Bibliographic Details
Main Authors: Bai, F., Li, H., Hao, Hong
Format: Conference Paper
Published: 2010
Online Access:http://hdl.handle.net/20.500.11937/4235
_version_ 1848744458501226496
author Bai, F.
Li, H.
Hao, Hong
author_facet Bai, F.
Li, H.
Hao, Hong
author_sort Bai, F.
building Curtin Institutional Repository
collection Online Access
description The collapses of transmission towers in large earthquakes were partially caused by the pulling forces from the transmission lines generated from out-of-phase responses of the adjacent towers owing to nonuniform ground motions. A three-dimensional finite element model of transmission tower-line system is established, the nonlinear responses of the structural system at uneven sites are analysed subjected to spatially varying ground motions, and the local site effect due to different soil condition sets on structural response is mainly studied. The spatially varying ground motions are simulated stochastically based on an empirical coherency loss function and a filtered Tajimi-Kanai power spectral density function. The site effect is considered by a transfer function derived from one dimensional wave propagation theory. Compared with structural responses calculated using the uniform sites assumption, numerical results indicate that seismic responses of transmission towers and power lines are amplified when considering the local site effects. Therefore, in order to ensure the seismic safety of transmission tower-line system, an accurate estimation of the site conditions where the structural system located is essential. © 2010 ASCE.
first_indexed 2025-11-14T06:01:47Z
format Conference Paper
id curtin-20.500.11937-4235
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:01:47Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-42352017-09-13T14:47:34Z Local site effect on seismic response of coupled transmission tower-line system Bai, F. Li, H. Hao, Hong The collapses of transmission towers in large earthquakes were partially caused by the pulling forces from the transmission lines generated from out-of-phase responses of the adjacent towers owing to nonuniform ground motions. A three-dimensional finite element model of transmission tower-line system is established, the nonlinear responses of the structural system at uneven sites are analysed subjected to spatially varying ground motions, and the local site effect due to different soil condition sets on structural response is mainly studied. The spatially varying ground motions are simulated stochastically based on an empirical coherency loss function and a filtered Tajimi-Kanai power spectral density function. The site effect is considered by a transfer function derived from one dimensional wave propagation theory. Compared with structural responses calculated using the uniform sites assumption, numerical results indicate that seismic responses of transmission towers and power lines are amplified when considering the local site effects. Therefore, in order to ensure the seismic safety of transmission tower-line system, an accurate estimation of the site conditions where the structural system located is essential. © 2010 ASCE. 2010 Conference Paper http://hdl.handle.net/20.500.11937/4235 10.1061/41096(366)270 restricted
spellingShingle Bai, F.
Li, H.
Hao, Hong
Local site effect on seismic response of coupled transmission tower-line system
title Local site effect on seismic response of coupled transmission tower-line system
title_full Local site effect on seismic response of coupled transmission tower-line system
title_fullStr Local site effect on seismic response of coupled transmission tower-line system
title_full_unstemmed Local site effect on seismic response of coupled transmission tower-line system
title_short Local site effect on seismic response of coupled transmission tower-line system
title_sort local site effect on seismic response of coupled transmission tower-line system
url http://hdl.handle.net/20.500.11937/4235