In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace

Posture and movement are thought to be important risk factors for the development of work-related musculoskeletal disorders. Whole day occupational exposure assessment has typically used self-report or observation techniques, but the need for more accurate measurement is now recognised. The aim of t...

Full description

Bibliographic Details
Main Authors: Straker, Leon, Campbell, Amity, Coleman, J., Ciccarelli, Marina, Dankaerts, W.
Format: Journal Article
Published: Taylor & Francis Ltd. 2010
Online Access:http://hdl.handle.net/20.500.11937/42088
_version_ 1848756323641982976
author Straker, Leon
Campbell, Amity
Coleman, J.
Ciccarelli, Marina
Dankaerts, W.
author_facet Straker, Leon
Campbell, Amity
Coleman, J.
Ciccarelli, Marina
Dankaerts, W.
author_sort Straker, Leon
building Curtin Institutional Repository
collection Online Access
description Posture and movement are thought to be important risk factors for the development of work-related musculoskeletal disorders. Whole day occupational exposure assessment has typically used self-report or observation techniques, but the need for more accurate measurement is now recognised. The aim of this study was to compare the kinematic recordings of a frequently used field system (physiometer) with two laboratory-based systems (Fastrak and Peak) in vivo. Head, thorax and right arm kinematics were recorded simultaneously by the three systems whilst a subject performed 27 single and multiple plane physiological and simulated daily living task movement trials. Errors observed in the Fastrak and Peak data included gimbal lock and quadrant errors. Physiometer data errors included undervalues, overvalues and temporal errors of slow response and resonance. All three systems showed some cross-talk. Agreement between the physiometer and the other systems was generally high for physiological movements (R2 > 0.8) and less for functional movements (R2 > 0.5).
first_indexed 2025-11-14T09:10:23Z
format Journal Article
id curtin-20.500.11937-42088
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:10:23Z
publishDate 2010
publisher Taylor & Francis Ltd.
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-420882017-10-24T00:36:54Z In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace Straker, Leon Campbell, Amity Coleman, J. Ciccarelli, Marina Dankaerts, W. Posture and movement are thought to be important risk factors for the development of work-related musculoskeletal disorders. Whole day occupational exposure assessment has typically used self-report or observation techniques, but the need for more accurate measurement is now recognised. The aim of this study was to compare the kinematic recordings of a frequently used field system (physiometer) with two laboratory-based systems (Fastrak and Peak) in vivo. Head, thorax and right arm kinematics were recorded simultaneously by the three systems whilst a subject performed 27 single and multiple plane physiological and simulated daily living task movement trials. Errors observed in the Fastrak and Peak data included gimbal lock and quadrant errors. Physiometer data errors included undervalues, overvalues and temporal errors of slow response and resonance. All three systems showed some cross-talk. Agreement between the physiometer and the other systems was generally high for physiological movements (R2 > 0.8) and less for functional movements (R2 > 0.5). 2010 Journal Article http://hdl.handle.net/20.500.11937/42088 10.1080/00140131003671975 Taylor & Francis Ltd. restricted
spellingShingle Straker, Leon
Campbell, Amity
Coleman, J.
Ciccarelli, Marina
Dankaerts, W.
In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace
title In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace
title_full In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace
title_fullStr In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace
title_full_unstemmed In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace
title_short In vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace
title_sort in vivo laboratory validation of the physiometer: a measurement system for long-term recording of posture and movements in the workplace
url http://hdl.handle.net/20.500.11937/42088