Cardiac Nuclear Imaging: Current Status and Future Directions

Cardiac single photon emission computed tomography (SPECT) and positron emission tomography (PET) are increasingly being used in the evaluation of patients with suspected or known coronary artery disease by assessing myocardial viability and perfusion and providing invaluable diagnostic and prognost...

Full description

Bibliographic Details
Main Authors: Sun, Zhonghua, Aziz, Aini ab, Md Yusof, Ahmad Khairuddin
Format: Journal Article
Published: Bentham Science Publishers 2013
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/41778
_version_ 1848756238395899904
author Sun, Zhonghua
Aziz, Aini ab
Md Yusof, Ahmad Khairuddin
author_facet Sun, Zhonghua
Aziz, Aini ab
Md Yusof, Ahmad Khairuddin
author_sort Sun, Zhonghua
building Curtin Institutional Repository
collection Online Access
description Cardiac single photon emission computed tomography (SPECT) and positron emission tomography (PET) are increasingly being used in the evaluation of patients with suspected or known coronary artery disease by assessing myocardial viability and perfusion and providing invaluable diagnostic and prognostic information. With their capacity to quantify left ventricular function as well as coronary flow reserve, these myocardial perfusion imaging techniques are superior to other methods for the detection of multivessel coronary artery disease and potentially, for risk stratification and prediction of cardiac events. Hybrid SPECT/CT and PET/CT scanners allow identification of flow-limiting coronary lesions and therefore offering great potential for both diagnosis and management. Advances in molecular biology of the cardiovascular system have helped to develop the molecular imaging which may be useful to evaluate targeted molecular and cellular abnormalities in the future. In this review, we will discuss the current state of the art in cardiac nuclear imaging, which include SPECT and PET evaluation of myocardial viability and perfusion. Radiopharmaceuticals used in cardiac SPECT and PET imaging are described, and radiation dose associated with the radiopharmaceuticals is briefly discussed. Clinical applications of hybrid imaging methods in coronary artery disease are presented and future directions are highlighted.
first_indexed 2025-11-14T09:09:01Z
format Journal Article
id curtin-20.500.11937-41778
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:09:01Z
publishDate 2013
publisher Bentham Science Publishers
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-417782017-09-13T16:00:28Z Cardiac Nuclear Imaging: Current Status and Future Directions Sun, Zhonghua Aziz, Aini ab Md Yusof, Ahmad Khairuddin Coronary artery disease single photon emission computed tomography myocardial perfusion imaging positron - emission tomography radiopharmaceuticals Cardiac single photon emission computed tomography (SPECT) and positron emission tomography (PET) are increasingly being used in the evaluation of patients with suspected or known coronary artery disease by assessing myocardial viability and perfusion and providing invaluable diagnostic and prognostic information. With their capacity to quantify left ventricular function as well as coronary flow reserve, these myocardial perfusion imaging techniques are superior to other methods for the detection of multivessel coronary artery disease and potentially, for risk stratification and prediction of cardiac events. Hybrid SPECT/CT and PET/CT scanners allow identification of flow-limiting coronary lesions and therefore offering great potential for both diagnosis and management. Advances in molecular biology of the cardiovascular system have helped to develop the molecular imaging which may be useful to evaluate targeted molecular and cellular abnormalities in the future. In this review, we will discuss the current state of the art in cardiac nuclear imaging, which include SPECT and PET evaluation of myocardial viability and perfusion. Radiopharmaceuticals used in cardiac SPECT and PET imaging are described, and radiation dose associated with the radiopharmaceuticals is briefly discussed. Clinical applications of hybrid imaging methods in coronary artery disease are presented and future directions are highlighted. 2013 Journal Article http://hdl.handle.net/20.500.11937/41778 10.2174/15734056113096660012 Bentham Science Publishers restricted
spellingShingle Coronary artery disease
single photon emission computed tomography
myocardial perfusion imaging
positron - emission tomography
radiopharmaceuticals
Sun, Zhonghua
Aziz, Aini ab
Md Yusof, Ahmad Khairuddin
Cardiac Nuclear Imaging: Current Status and Future Directions
title Cardiac Nuclear Imaging: Current Status and Future Directions
title_full Cardiac Nuclear Imaging: Current Status and Future Directions
title_fullStr Cardiac Nuclear Imaging: Current Status and Future Directions
title_full_unstemmed Cardiac Nuclear Imaging: Current Status and Future Directions
title_short Cardiac Nuclear Imaging: Current Status and Future Directions
title_sort cardiac nuclear imaging: current status and future directions
topic Coronary artery disease
single photon emission computed tomography
myocardial perfusion imaging
positron - emission tomography
radiopharmaceuticals
url http://hdl.handle.net/20.500.11937/41778