Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces

Electrochemistry at liquid–liquid interfaces, or at interfaces between two immiscible electrolyte solutions ITIES, provides a basis for the non-redox detection of biological molecules, based on ion-transferor adsorption processes. The electroactivity of myoglobin at an array of micron-sized liquid–o...

Full description

Bibliographic Details
Main Authors: O'Sullivan, S., Arrigan, Damien
Format: Journal Article
Published: Pergamon 2012
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/41703
_version_ 1848756218541113344
author O'Sullivan, S.
Arrigan, Damien
author_facet O'Sullivan, S.
Arrigan, Damien
author_sort O'Sullivan, S.
building Curtin Institutional Repository
collection Online Access
description Electrochemistry at liquid–liquid interfaces, or at interfaces between two immiscible electrolyte solutions ITIES, provides a basis for the non-redox detection of biological molecules, based on ion-transferor adsorption processes. The electroactivity of myoglobin at an array of micron-sized liquid–organogel interfaces was investigated. The μITIES array was patterned with a silicon membrane consisting of an array of eight pores with radii of ~12.8 μm and a pore to pore separation of ~400 μm. Using cyclic voltammetry at the ITIES, the protein was shown to adsorb at the interface and facilitate the transfer of the organic phase electrolyte anions to the aqueous side of the interface. The electrochemical current response was linear with concentration in the range of 1–6 μM, with corresponding surface coverage of 10–50 pmol cm-2. The reverse peak currents was found to be proportional to the voltammetric scan rate, indicating a desorption process. The detection of the protein was only possibly when the pH of the aqueous phase solution was below the pI of the protein. The steady-state simple ion transfer behaviour of tetraethylammonium cation was decreased on the forward sweep, providing a qualitative indication of the presence of adsorbed protein at the interface. Increasing the ionic strength of the aqueous phase resulted in enhanced peak currents, possibly due to aggregation of protein precipitates in the aqueous solution. UV/Vis absorbance spectroscopy was used to investigate the effects of various aqueous electrolyte solutions on the structure of the protein, and it was shown that at low pH the protein is at least partially denatured. These results provide the basis for label-free detection of myoglobin at the ITIES.
first_indexed 2025-11-14T09:08:42Z
format Journal Article
id curtin-20.500.11937-41703
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:08:42Z
publishDate 2012
publisher Pergamon
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-417032017-09-13T15:59:40Z Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces O'Sullivan, S. Arrigan, Damien voltammetry liquid–liquid interface ITIES myoglobin adsorption Electrochemistry at liquid–liquid interfaces, or at interfaces between two immiscible electrolyte solutions ITIES, provides a basis for the non-redox detection of biological molecules, based on ion-transferor adsorption processes. The electroactivity of myoglobin at an array of micron-sized liquid–organogel interfaces was investigated. The μITIES array was patterned with a silicon membrane consisting of an array of eight pores with radii of ~12.8 μm and a pore to pore separation of ~400 μm. Using cyclic voltammetry at the ITIES, the protein was shown to adsorb at the interface and facilitate the transfer of the organic phase electrolyte anions to the aqueous side of the interface. The electrochemical current response was linear with concentration in the range of 1–6 μM, with corresponding surface coverage of 10–50 pmol cm-2. The reverse peak currents was found to be proportional to the voltammetric scan rate, indicating a desorption process. The detection of the protein was only possibly when the pH of the aqueous phase solution was below the pI of the protein. The steady-state simple ion transfer behaviour of tetraethylammonium cation was decreased on the forward sweep, providing a qualitative indication of the presence of adsorbed protein at the interface. Increasing the ionic strength of the aqueous phase resulted in enhanced peak currents, possibly due to aggregation of protein precipitates in the aqueous solution. UV/Vis absorbance spectroscopy was used to investigate the effects of various aqueous electrolyte solutions on the structure of the protein, and it was shown that at low pH the protein is at least partially denatured. These results provide the basis for label-free detection of myoglobin at the ITIES. 2012 Journal Article http://hdl.handle.net/20.500.11937/41703 10.1016/j.electacta.2012.05.070 Pergamon fulltext
spellingShingle voltammetry
liquid–liquid interface
ITIES
myoglobin
adsorption
O'Sullivan, S.
Arrigan, Damien
Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
title Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
title_full Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
title_fullStr Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
title_full_unstemmed Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
title_short Electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
title_sort electrochemical behaviour of myoglobin at an array of microscopic liquid–liquid interfaces
topic voltammetry
liquid–liquid interface
ITIES
myoglobin
adsorption
url http://hdl.handle.net/20.500.11937/41703