Screening of carbonaceous nanoporous materials for capture of nerve agents

A strategy for combined experimental and computational screening of candidate carbonaceous materials for capturing highly volatile nerve agents at ambient temperature using physisorption. Based on theoretical calculations of Henry constants and zero-coverage adsorption enthalpies for sarin and DMMP...

Full description

Bibliographic Details
Main Authors: Kowalczyk, Piotr, Gauden, P., Terzyk, A., Neimark, A.
Format: Journal Article
Published: R S C Publications 2013
Online Access:http://hdl.handle.net/20.500.11937/40842
_version_ 1848755979827544064
author Kowalczyk, Piotr
Gauden, P.
Terzyk, A.
Neimark, A.
author_facet Kowalczyk, Piotr
Gauden, P.
Terzyk, A.
Neimark, A.
author_sort Kowalczyk, Piotr
building Curtin Institutional Repository
collection Online Access
description A strategy for combined experimental and computational screening of candidate carbonaceous materials for capturing highly volatile nerve agents at ambient temperature using physisorption. Based on theoretical calculations of Henry constants and zero-coverage adsorption enthalpies for sarin and DMMP (its common stimulant) adsorbed in model slit-shaped carbon pores at 298 K, we found the following. Slit-shaped carbon pores with pore width 0.5 nm are optimal for agent adsorption due to strong confinement of adsorbed molecules. Agent adsorption enthalpy at zero coverage computed for optimal pore width is very high and reaches 83 kJ mol-1. Widening of pore width above 1 nm results in a significant decrease of the Henry constant and zero-coverage adsorption enthalpy (44 kJ mol-1). Polydispersity of studied candidate carbonaceous materials strongly affects adsorption capacity for DMMP under the operating conditions. The optimal carbonaceous adsorbent, pitch-based P7 activated carbon fiber, adsorbed 100 µg g-1 DMMP at 0.03 µg m-3. Commercial Norit activated carbon adsorbed only 20 µg g-1 DMMP at 0.03 µg m-3. Surprisingly, a small shift of the pore size distribution towards wider micropores has a great impact on agent adsorption. Because the adsorption enthalpies computed at zero coverage weakly dependent on pore size, the heat released during agent adsorption is similar for all studied candidate adsorbents (i.e. 55–60 kJ mol-1).
first_indexed 2025-11-14T09:04:55Z
format Journal Article
id curtin-20.500.11937-40842
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:04:55Z
publishDate 2013
publisher R S C Publications
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-408422017-09-13T15:57:40Z Screening of carbonaceous nanoporous materials for capture of nerve agents Kowalczyk, Piotr Gauden, P. Terzyk, A. Neimark, A. A strategy for combined experimental and computational screening of candidate carbonaceous materials for capturing highly volatile nerve agents at ambient temperature using physisorption. Based on theoretical calculations of Henry constants and zero-coverage adsorption enthalpies for sarin and DMMP (its common stimulant) adsorbed in model slit-shaped carbon pores at 298 K, we found the following. Slit-shaped carbon pores with pore width 0.5 nm are optimal for agent adsorption due to strong confinement of adsorbed molecules. Agent adsorption enthalpy at zero coverage computed for optimal pore width is very high and reaches 83 kJ mol-1. Widening of pore width above 1 nm results in a significant decrease of the Henry constant and zero-coverage adsorption enthalpy (44 kJ mol-1). Polydispersity of studied candidate carbonaceous materials strongly affects adsorption capacity for DMMP under the operating conditions. The optimal carbonaceous adsorbent, pitch-based P7 activated carbon fiber, adsorbed 100 µg g-1 DMMP at 0.03 µg m-3. Commercial Norit activated carbon adsorbed only 20 µg g-1 DMMP at 0.03 µg m-3. Surprisingly, a small shift of the pore size distribution towards wider micropores has a great impact on agent adsorption. Because the adsorption enthalpies computed at zero coverage weakly dependent on pore size, the heat released during agent adsorption is similar for all studied candidate adsorbents (i.e. 55–60 kJ mol-1). 2013 Journal Article http://hdl.handle.net/20.500.11937/40842 10.1039/C2CP43366D R S C Publications restricted
spellingShingle Kowalczyk, Piotr
Gauden, P.
Terzyk, A.
Neimark, A.
Screening of carbonaceous nanoporous materials for capture of nerve agents
title Screening of carbonaceous nanoporous materials for capture of nerve agents
title_full Screening of carbonaceous nanoporous materials for capture of nerve agents
title_fullStr Screening of carbonaceous nanoporous materials for capture of nerve agents
title_full_unstemmed Screening of carbonaceous nanoporous materials for capture of nerve agents
title_short Screening of carbonaceous nanoporous materials for capture of nerve agents
title_sort screening of carbonaceous nanoporous materials for capture of nerve agents
url http://hdl.handle.net/20.500.11937/40842