Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry

The use of pulsating impinging jets has been found to have both enhancing as well as deteriorating heat transfer characteristics as compared to traditional steady state jets, depending on the operating conditions. Liquid jet impingement is preferred over air jets for several applications due to thei...

Full description

Bibliographic Details
Main Authors: Sridhar, Abishek, Narayanaswamy, Ramesh, Narayanan, V.
Other Authors: Professor P.K.Das
Format: Conference Paper
Published: IIT Kharagpur 2013
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/40779
_version_ 1848755962680180736
author Sridhar, Abishek
Narayanaswamy, Ramesh
Narayanan, V.
author2 Professor P.K.Das
author_facet Professor P.K.Das
Sridhar, Abishek
Narayanaswamy, Ramesh
Narayanan, V.
author_sort Sridhar, Abishek
building Curtin Institutional Repository
collection Online Access
description The use of pulsating impinging jets has been found to have both enhancing as well as deteriorating heat transfer characteristics as compared to traditional steady state jets, depending on the operating conditions. Liquid jet impingement is preferred over air jets for several applications due to their substantially much larger heat transfer coefficients. While there is considerable literature on heat transfer characteristics associated with pulsating air jet impingement, that on the effect of jet pulsations for submerged liquid jet impingement cooling configurations is sparse. An experimental investigation is thus carried out to study the effect of pulsation frequency and amplitude for submerged slot jet impingement cooling of de-ionized water on a heated aluminium surface for Reynolds numbers in the range 500 - 3400, frequencies of 0.25 Hz and 0.5 Hz, and amplitudes of 50% and 100% of mean flow. In addition, steady state experiments were also carried out for 800 ≤ Re ≤ 7000 for three different jet inlet temperatures 34.83 °C, 39.68 °C and 44.54 °C. For the range of parameters studied, it was found that the effects of jet pulsations are only marginal on the time-averaged heat transfer characteristics. While the effect of jet pulsations was negligible for Reynolds numbers up to 1000, a slight decrease (up to 12%) was observed in the Nusselt number for larger Reynolds numbers with jet pulsations.
first_indexed 2025-11-14T09:04:38Z
format Conference Paper
id curtin-20.500.11937-40779
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T09:04:38Z
publishDate 2013
publisher IIT Kharagpur
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-407792017-02-28T01:46:49Z Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry Sridhar, Abishek Narayanaswamy, Ramesh Narayanan, V. Professor P.K.Das jet impingement liquid pulsed frequency The use of pulsating impinging jets has been found to have both enhancing as well as deteriorating heat transfer characteristics as compared to traditional steady state jets, depending on the operating conditions. Liquid jet impingement is preferred over air jets for several applications due to their substantially much larger heat transfer coefficients. While there is considerable literature on heat transfer characteristics associated with pulsating air jet impingement, that on the effect of jet pulsations for submerged liquid jet impingement cooling configurations is sparse. An experimental investigation is thus carried out to study the effect of pulsation frequency and amplitude for submerged slot jet impingement cooling of de-ionized water on a heated aluminium surface for Reynolds numbers in the range 500 - 3400, frequencies of 0.25 Hz and 0.5 Hz, and amplitudes of 50% and 100% of mean flow. In addition, steady state experiments were also carried out for 800 ≤ Re ≤ 7000 for three different jet inlet temperatures 34.83 °C, 39.68 °C and 44.54 °C. For the range of parameters studied, it was found that the effects of jet pulsations are only marginal on the time-averaged heat transfer characteristics. While the effect of jet pulsations was negligible for Reynolds numbers up to 1000, a slight decrease (up to 12%) was observed in the Nusselt number for larger Reynolds numbers with jet pulsations. 2013 Conference Paper http://hdl.handle.net/20.500.11937/40779 IIT Kharagpur restricted
spellingShingle jet impingement
liquid
pulsed
frequency
Sridhar, Abishek
Narayanaswamy, Ramesh
Narayanan, V.
Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry
title Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry
title_full Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry
title_fullStr Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry
title_full_unstemmed Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry
title_short Experimental Study of Low Frequency Pulsating Liquid Jet Impingement in a confined planar geometry
title_sort experimental study of low frequency pulsating liquid jet impingement in a confined planar geometry
topic jet impingement
liquid
pulsed
frequency
url http://hdl.handle.net/20.500.11937/40779