Modifying track layout from straight to circular has a modest effect on the 6-min walk distance

Background: The protocol used for the 6-min walk test (6MWT) influences its results. The only study to examine the effect of modifying track layout performed a retrospective analysis and concluded that institutions using continuous tracks yield greater distances than those using straight tracks. Agr...

Full description

Bibliographic Details
Main Authors: Bansal, V., Hill, Kylie, Dolmage, T., Brooks, D., Woon, L., Goldstein, R.
Format: Journal Article
Published: American College of Chest Physicians 2008
Online Access:http://hdl.handle.net/20.500.11937/39529
_version_ 1848755615744131072
author Bansal, V.
Hill, Kylie
Dolmage, T.
Brooks, D.
Woon, L.
Goldstein, R.
author_facet Bansal, V.
Hill, Kylie
Dolmage, T.
Brooks, D.
Woon, L.
Goldstein, R.
author_sort Bansal, V.
building Curtin Institutional Repository
collection Online Access
description Background: The protocol used for the 6-min walk test (6MWT) influences its results. The only study to examine the effect of modifying track layout performed a retrospective analysis and concluded that institutions using continuous tracks yield greater distances than those using straight tracks. Agreement between the distances measured on different tracks could not be examined. We evaluated the effect of modifying track layout on walk distance and examined the agreement and repeatability of distances measured on different tracks. Methods: In a prospective, randomized, cross-over study, 27 COPD subjects (FEV1, 38 ± 14% [mean ± SD]; 15 men) attended three separate test sessions, completing six 6MWTs. To familiarize all subjects with both tracks, the first two sessions comprised two 6MWTs on either a circular or straight track. During the final session, each subject was tested once on the straight and once on the circular track. Results: The distance walked on the circular track exceeded the straight track by 13 ± 17 m (p < 0.001). The limit of agreement between tracks was 33 m. Coefficient of repeatability values when the test was completed on different days for the straight and circular tracks were 51 m and 65 m, respectively. Conclusions: When evaluating changes in 6-min walk distance in groups of patients, track layout should be standardized. However, the effect of modifying track layout on an individual's walking distance is small compared to their daily variability in walk distance. Therefore, standardizing track layout for any given individual may be inconsequential when evaluating the change in distances from tests performed on different days.
first_indexed 2025-11-14T08:59:07Z
format Journal Article
id curtin-20.500.11937-39529
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:59:07Z
publishDate 2008
publisher American College of Chest Physicians
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-395292017-09-13T14:26:12Z Modifying track layout from straight to circular has a modest effect on the 6-min walk distance Bansal, V. Hill, Kylie Dolmage, T. Brooks, D. Woon, L. Goldstein, R. Background: The protocol used for the 6-min walk test (6MWT) influences its results. The only study to examine the effect of modifying track layout performed a retrospective analysis and concluded that institutions using continuous tracks yield greater distances than those using straight tracks. Agreement between the distances measured on different tracks could not be examined. We evaluated the effect of modifying track layout on walk distance and examined the agreement and repeatability of distances measured on different tracks. Methods: In a prospective, randomized, cross-over study, 27 COPD subjects (FEV1, 38 ± 14% [mean ± SD]; 15 men) attended three separate test sessions, completing six 6MWTs. To familiarize all subjects with both tracks, the first two sessions comprised two 6MWTs on either a circular or straight track. During the final session, each subject was tested once on the straight and once on the circular track. Results: The distance walked on the circular track exceeded the straight track by 13 ± 17 m (p < 0.001). The limit of agreement between tracks was 33 m. Coefficient of repeatability values when the test was completed on different days for the straight and circular tracks were 51 m and 65 m, respectively. Conclusions: When evaluating changes in 6-min walk distance in groups of patients, track layout should be standardized. However, the effect of modifying track layout on an individual's walking distance is small compared to their daily variability in walk distance. Therefore, standardizing track layout for any given individual may be inconsequential when evaluating the change in distances from tests performed on different days. 2008 Journal Article http://hdl.handle.net/20.500.11937/39529 10.1378/chest.07-2823 American College of Chest Physicians restricted
spellingShingle Bansal, V.
Hill, Kylie
Dolmage, T.
Brooks, D.
Woon, L.
Goldstein, R.
Modifying track layout from straight to circular has a modest effect on the 6-min walk distance
title Modifying track layout from straight to circular has a modest effect on the 6-min walk distance
title_full Modifying track layout from straight to circular has a modest effect on the 6-min walk distance
title_fullStr Modifying track layout from straight to circular has a modest effect on the 6-min walk distance
title_full_unstemmed Modifying track layout from straight to circular has a modest effect on the 6-min walk distance
title_short Modifying track layout from straight to circular has a modest effect on the 6-min walk distance
title_sort modifying track layout from straight to circular has a modest effect on the 6-min walk distance
url http://hdl.handle.net/20.500.11937/39529