The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids

The electrochemical reduction of 1 atm hydrogen sulfide gas (H2S) has been studied at a platinum microelectrode (10 µm diameter) in five room temperature ionic liquids (RTILs): [C2mim][NTf2], [C4mpyrr][NTf2], [C4mim][OTf], [C4mim][NO3], and [C4mim][PF6] (where [Cnmim]+ = 1-alkyl-3-methylimidazolium,...

Full description

Bibliographic Details
Main Authors: O'Mahony, A., Silvester, Debbie, Aldous, L., Hardacre, C., Compton, R.
Format: Journal Article
Published: American Chemical Society 2008
Online Access:http://hdl.handle.net/20.500.11937/37196
_version_ 1848754980242063360
author O'Mahony, A.
Silvester, Debbie
Aldous, L.
Hardacre, C.
Compton, R.
author_facet O'Mahony, A.
Silvester, Debbie
Aldous, L.
Hardacre, C.
Compton, R.
author_sort O'Mahony, A.
building Curtin Institutional Repository
collection Online Access
description The electrochemical reduction of 1 atm hydrogen sulfide gas (H2S) has been studied at a platinum microelectrode (10 µm diameter) in five room temperature ionic liquids (RTILs): [C2mim][NTf2], [C4mpyrr][NTf2], [C4mim][OTf], [C4mim][NO3], and [C4mim][PF6] (where [Cnmim]+ = 1-alkyl-3-methylimidazolium, [NTf2]− = bis(trifluoromethylsulfonyl)imide, [C4mpyrr]+ = N-butyl- N-methylpyrrolidinium, [OTf]− = trifluoromethlysulfonate, [NO3]− = nitrate, and [PF6]− = hexafluorophosphate). In all five RTILs, a chemically irreversible reduction peak was observed on the reductive sweep, followed by one or two oxidative peaks on the reverse scan. The oxidation peaks were assigned to the oxidation of SH− and adsorbed hydrogen. In addition, a small reductive peak was observed prior to the large wave in [C2mim][NTf2] only, which may be due to the reduction of a sulfur impurity in the gas. Potential-step chronoamperometry was carried out on the reduction peak of H2S, revealing diffusion coefficients of 3.2, 4.6, 2.4, 2.7, and 3.1 × 10−10 m2 s−1 and solubilities of 529, 236, 537, 438, and 230 mM in [C2mim][NTf2], [C4mpyrr][NTf2], [C4mim][OTf], [C4mim][NO3], and [C4mim][PF6], respectively. The solubilities of H2S in RTILs are much higher than those reported in conventional molecular solvents, suggesting that RTILs may be very favorable gas sensing media for H2S detection.
first_indexed 2025-11-14T08:49:01Z
format Journal Article
id curtin-20.500.11937-37196
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:49:01Z
publishDate 2008
publisher American Chemical Society
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-371962017-09-13T13:37:31Z The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids O'Mahony, A. Silvester, Debbie Aldous, L. Hardacre, C. Compton, R. The electrochemical reduction of 1 atm hydrogen sulfide gas (H2S) has been studied at a platinum microelectrode (10 µm diameter) in five room temperature ionic liquids (RTILs): [C2mim][NTf2], [C4mpyrr][NTf2], [C4mim][OTf], [C4mim][NO3], and [C4mim][PF6] (where [Cnmim]+ = 1-alkyl-3-methylimidazolium, [NTf2]− = bis(trifluoromethylsulfonyl)imide, [C4mpyrr]+ = N-butyl- N-methylpyrrolidinium, [OTf]− = trifluoromethlysulfonate, [NO3]− = nitrate, and [PF6]− = hexafluorophosphate). In all five RTILs, a chemically irreversible reduction peak was observed on the reductive sweep, followed by one or two oxidative peaks on the reverse scan. The oxidation peaks were assigned to the oxidation of SH− and adsorbed hydrogen. In addition, a small reductive peak was observed prior to the large wave in [C2mim][NTf2] only, which may be due to the reduction of a sulfur impurity in the gas. Potential-step chronoamperometry was carried out on the reduction peak of H2S, revealing diffusion coefficients of 3.2, 4.6, 2.4, 2.7, and 3.1 × 10−10 m2 s−1 and solubilities of 529, 236, 537, 438, and 230 mM in [C2mim][NTf2], [C4mpyrr][NTf2], [C4mim][OTf], [C4mim][NO3], and [C4mim][PF6], respectively. The solubilities of H2S in RTILs are much higher than those reported in conventional molecular solvents, suggesting that RTILs may be very favorable gas sensing media for H2S detection. 2008 Journal Article http://hdl.handle.net/20.500.11937/37196 10.1021/jp800819k American Chemical Society restricted
spellingShingle O'Mahony, A.
Silvester, Debbie
Aldous, L.
Hardacre, C.
Compton, R.
The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids
title The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids
title_full The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids
title_fullStr The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids
title_full_unstemmed The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids
title_short The Electrochemical Reduction of Hydrogen Sulfide on Platinum in Several Room Temperature Ionic Liquids
title_sort electrochemical reduction of hydrogen sulfide on platinum in several room temperature ionic liquids
url http://hdl.handle.net/20.500.11937/37196