Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction

Interventional bronchoscopists manage central airway obstruction (CAO) through dilation, tumor ablation, and/or stent insertion. Anatomical optical coherence tomography (aOCT), a validated light-based imaging technique, has the unique capacity of providing bronchoscopists with intraprocedural centra...

Full description

Bibliographic Details
Main Authors: Williamson, J., McLaughlin, R., Phillips, M., Curatolo, A., Armstrong, J., Maddison, K., Sheehan, R., Sampson, D., Hillman, D., Eastwood, Peter
Format: Journal Article
Published: 2010
Online Access:http://hdl.handle.net/20.500.11937/35969
_version_ 1848754639789359104
author Williamson, J.
McLaughlin, R.
Phillips, M.
Curatolo, A.
Armstrong, J.
Maddison, K.
Sheehan, R.
Sampson, D.
Hillman, D.
Eastwood, Peter
author_facet Williamson, J.
McLaughlin, R.
Phillips, M.
Curatolo, A.
Armstrong, J.
Maddison, K.
Sheehan, R.
Sampson, D.
Hillman, D.
Eastwood, Peter
author_sort Williamson, J.
building Curtin Institutional Repository
collection Online Access
description Interventional bronchoscopists manage central airway obstruction (CAO) through dilation, tumor ablation, and/or stent insertion. Anatomical optical coherence tomography (aOCT), a validated light-based imaging technique, has the unique capacity of providing bronchoscopists with intraprocedural central airway measurements. This study aims to describe the potential role of real-time aOCT in guiding interventions during CAO procedures. Methods: Prospective case series were recruited from patients referred for bronchoscopic management of symptomatic CAO. Preprocedure chest computed tomography (CT) scans were analyzed for relevant airway dimensions, such as stenosis caliber and length, and aided procedure planning. During bronchoscopy, an aOCT fiberoptic probe was inserted through the working channel of the bronchoscope to image the airway stenosis. From these aOCT images, stenosis dimensions were measured and compared with the preprocedure CT measurements. Preprocedure and postprocedure spirometry, Medical Research Council dyspnea score, and Eastern Cooperative Oncology Group performance status were collected to assess intervention efficacy. Results: Fourteen patients were studied. CT and aOCT-based measurements of airway caliber and length correlated closely (r 2=0.87, P < 0.001). Bland-Altman analysis showed strong agreement between measurements (mean difference 0.4 ± 8.6 mm). The real-time nature of aOCT imaging provided the advantage of more up-to-date measurements where a delay occurred between CT and bronchoscopy or where the quality of the CT image was suboptimal. After bronchoscopy, the predicted forced expiratory flow in 1 second increased from 67 ± 26% to 78 ± 19% (P = 0.04). Eastern Cooperative Oncology Group and dyspnea scores improved in 83% and 75% of the patients, respectively. Conclusions: aOCT provides real-time measurements of obstructing central airway lesions that can assist therapeutic interventions such as selection of endobronchial stents and airway dilatation procedures. Copyright © 2010 by Lippincott Williams & Wilkins.
first_indexed 2025-11-14T08:43:37Z
format Journal Article
id curtin-20.500.11937-35969
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:43:37Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-359692017-09-13T15:17:39Z Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction Williamson, J. McLaughlin, R. Phillips, M. Curatolo, A. Armstrong, J. Maddison, K. Sheehan, R. Sampson, D. Hillman, D. Eastwood, Peter Interventional bronchoscopists manage central airway obstruction (CAO) through dilation, tumor ablation, and/or stent insertion. Anatomical optical coherence tomography (aOCT), a validated light-based imaging technique, has the unique capacity of providing bronchoscopists with intraprocedural central airway measurements. This study aims to describe the potential role of real-time aOCT in guiding interventions during CAO procedures. Methods: Prospective case series were recruited from patients referred for bronchoscopic management of symptomatic CAO. Preprocedure chest computed tomography (CT) scans were analyzed for relevant airway dimensions, such as stenosis caliber and length, and aided procedure planning. During bronchoscopy, an aOCT fiberoptic probe was inserted through the working channel of the bronchoscope to image the airway stenosis. From these aOCT images, stenosis dimensions were measured and compared with the preprocedure CT measurements. Preprocedure and postprocedure spirometry, Medical Research Council dyspnea score, and Eastern Cooperative Oncology Group performance status were collected to assess intervention efficacy. Results: Fourteen patients were studied. CT and aOCT-based measurements of airway caliber and length correlated closely (r 2=0.87, P < 0.001). Bland-Altman analysis showed strong agreement between measurements (mean difference 0.4 ± 8.6 mm). The real-time nature of aOCT imaging provided the advantage of more up-to-date measurements where a delay occurred between CT and bronchoscopy or where the quality of the CT image was suboptimal. After bronchoscopy, the predicted forced expiratory flow in 1 second increased from 67 ± 26% to 78 ± 19% (P = 0.04). Eastern Cooperative Oncology Group and dyspnea scores improved in 83% and 75% of the patients, respectively. Conclusions: aOCT provides real-time measurements of obstructing central airway lesions that can assist therapeutic interventions such as selection of endobronchial stents and airway dilatation procedures. Copyright © 2010 by Lippincott Williams & Wilkins. 2010 Journal Article http://hdl.handle.net/20.500.11937/35969 10.1097/LBR.0b013e3181f9eaae restricted
spellingShingle Williamson, J.
McLaughlin, R.
Phillips, M.
Curatolo, A.
Armstrong, J.
Maddison, K.
Sheehan, R.
Sampson, D.
Hillman, D.
Eastwood, Peter
Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction
title Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction
title_full Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction
title_fullStr Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction
title_full_unstemmed Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction
title_short Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction
title_sort feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction
url http://hdl.handle.net/20.500.11937/35969