Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS

This paper concentrates on design and analysis of STATCOM connected at the wind farm terminal in real time environment using Real Time Digital Simulator (RTDS). This work is a part of power hardware-in-loop (PHIL) test required in a future project, and therefore, individual components are models in...

Full description

Bibliographic Details
Main Authors: Sattar, A., Al-Durra, A., Muyeen, S.M.
Format: Conference Paper
Published: 2011
Online Access:http://hdl.handle.net/20.500.11937/35705
_version_ 1848754568280670208
author Sattar, A.
Al-Durra, A.
Muyeen, S.M.
author_facet Sattar, A.
Al-Durra, A.
Muyeen, S.M.
author_sort Sattar, A.
building Curtin Institutional Repository
collection Online Access
description This paper concentrates on design and analysis of STATCOM connected at the wind farm terminal in real time environment using Real Time Digital Simulator (RTDS). This work is a part of power hardware-in-loop (PHIL) test required in a future project, and therefore, individual components are models in such a way that is close to real system. For the sake of detail analyses and future study, the system is simulated in two ways. First method is a dual time step approach, where wind turbines and generators of a wind farm, power grid, and control system are realized in the large time-step main network, however, 2-level voltage source converter based STATCOM is modeled in RTDS small time-step environment to adapt with higher switching frequency, where interface transformer is used to link the different time step sub-networks. In the second method, the entire system including the STATCOM is simulated in large time step. Detailed switching scheme for STATCOM and control strategy for both methods are discussed. An option for integrating anemometer for dynamic characteristics analysis is kept open, difficulties of STATCOM switching schemes for control prototype and PHIL testing in RTDS environment are discussed. The merits and demerits of both methods are also presented which is one of the salient features of this study. Results of RTDS are compared with Laboratory standard power system software PSCAD/EMTDC and the features of using RTDS in dynamic characteristics analyses of wind farm are also discussed.
first_indexed 2025-11-14T08:42:29Z
format Conference Paper
id curtin-20.500.11937-35705
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:42:29Z
publishDate 2011
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-357052017-09-13T16:11:35Z Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS Sattar, A. Al-Durra, A. Muyeen, S.M. This paper concentrates on design and analysis of STATCOM connected at the wind farm terminal in real time environment using Real Time Digital Simulator (RTDS). This work is a part of power hardware-in-loop (PHIL) test required in a future project, and therefore, individual components are models in such a way that is close to real system. For the sake of detail analyses and future study, the system is simulated in two ways. First method is a dual time step approach, where wind turbines and generators of a wind farm, power grid, and control system are realized in the large time-step main network, however, 2-level voltage source converter based STATCOM is modeled in RTDS small time-step environment to adapt with higher switching frequency, where interface transformer is used to link the different time step sub-networks. In the second method, the entire system including the STATCOM is simulated in large time step. Detailed switching scheme for STATCOM and control strategy for both methods are discussed. An option for integrating anemometer for dynamic characteristics analysis is kept open, difficulties of STATCOM switching schemes for control prototype and PHIL testing in RTDS environment are discussed. The merits and demerits of both methods are also presented which is one of the salient features of this study. Results of RTDS are compared with Laboratory standard power system software PSCAD/EMTDC and the features of using RTDS in dynamic characteristics analyses of wind farm are also discussed. 2011 Conference Paper http://hdl.handle.net/20.500.11937/35705 10.1109/EPQU.2011.6128880 fulltext
spellingShingle Sattar, A.
Al-Durra, A.
Muyeen, S.M.
Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS
title Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS
title_full Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS
title_fullStr Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS
title_full_unstemmed Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS
title_short Dynamic characteristics analysis of wind farm integrated with STATCOM using RTDS
title_sort dynamic characteristics analysis of wind farm integrated with statcom using rtds
url http://hdl.handle.net/20.500.11937/35705