CFD based identification of clinker formation regions in large scale utility boiler

Pulverised coal combustion continues to be one of the main conventional methods of producing electricity over the last several decades. Mineral matter present in coal may occur as free ions, salts, organically associated inorganic elements and crystalline minerals. During coal combustion this minera...

Full description

Bibliographic Details
Main Authors: Vuthaluru, Hari, Kotadiya, Nilesh, Vuthaluru, Rupa, French, D.
Format: Journal Article
Published: Elsevier 2011
Online Access:http://hdl.handle.net/20.500.11937/35570
_version_ 1848754532174004224
author Vuthaluru, Hari
Kotadiya, Nilesh
Vuthaluru, Rupa
French, D.
author_facet Vuthaluru, Hari
Kotadiya, Nilesh
Vuthaluru, Rupa
French, D.
author_sort Vuthaluru, Hari
building Curtin Institutional Repository
collection Online Access
description Pulverised coal combustion continues to be one of the main conventional methods of producing electricity over the last several decades. Mineral matter present in coal may occur as free ions, salts, organically associated inorganic elements and crystalline minerals. During coal combustion this mineral matter may partly vapourise, fragment or coalesce. The mineral matter in coal transforms into ash during combustion which may result in ash deposition causing problems such as fouling and slagging. Slagging deposits forming in the radiation zone directly exposed to the flame radiation are generally called clinkers whereas sintered deposits formed in the convection zone not directly exposed by flame radiation are referred to as fouling deposits. The paper deals with clinker formation in a typical 330MW boiler using the commercial computational fluid dynamic code FLUENT and several available empirical indices, the latter indices being used to calculate the slagging propensity of the feed coal. The temperature distribution, velocity profiles and particle trajectories were analysed and utilised to predict likely zones of clinker formation. The most probable locations for clinker formation were found to be in the radiation zone near to nose of the furnace and the left-top side of the superheater tube sections which agrees closely with empirical plant observations. However, empirical slagging indices indicate a low to medium slagging propensity. Comparisons between the clinker formation temperatures based on the ash analysis (corresponding phase diagram) of selected clinkers from large scale boiler and CFD based temperatures for selected regions showed good agreement suggesting that the modelling based identification is reliable and can be valuable for power utilities in the development of soot blowing strategies to minimise the formation of clinker deposits.
first_indexed 2025-11-14T08:41:54Z
format Journal Article
id curtin-20.500.11937-35570
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:41:54Z
publishDate 2011
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-355702017-09-13T16:08:22Z CFD based identification of clinker formation regions in large scale utility boiler Vuthaluru, Hari Kotadiya, Nilesh Vuthaluru, Rupa French, D. Pulverised coal combustion continues to be one of the main conventional methods of producing electricity over the last several decades. Mineral matter present in coal may occur as free ions, salts, organically associated inorganic elements and crystalline minerals. During coal combustion this mineral matter may partly vapourise, fragment or coalesce. The mineral matter in coal transforms into ash during combustion which may result in ash deposition causing problems such as fouling and slagging. Slagging deposits forming in the radiation zone directly exposed to the flame radiation are generally called clinkers whereas sintered deposits formed in the convection zone not directly exposed by flame radiation are referred to as fouling deposits. The paper deals with clinker formation in a typical 330MW boiler using the commercial computational fluid dynamic code FLUENT and several available empirical indices, the latter indices being used to calculate the slagging propensity of the feed coal. The temperature distribution, velocity profiles and particle trajectories were analysed and utilised to predict likely zones of clinker formation. The most probable locations for clinker formation were found to be in the radiation zone near to nose of the furnace and the left-top side of the superheater tube sections which agrees closely with empirical plant observations. However, empirical slagging indices indicate a low to medium slagging propensity. Comparisons between the clinker formation temperatures based on the ash analysis (corresponding phase diagram) of selected clinkers from large scale boiler and CFD based temperatures for selected regions showed good agreement suggesting that the modelling based identification is reliable and can be valuable for power utilities in the development of soot blowing strategies to minimise the formation of clinker deposits. 2011 Journal Article http://hdl.handle.net/20.500.11937/35570 10.1016/j.applthermaleng.2010.12.032 Elsevier restricted
spellingShingle Vuthaluru, Hari
Kotadiya, Nilesh
Vuthaluru, Rupa
French, D.
CFD based identification of clinker formation regions in large scale utility boiler
title CFD based identification of clinker formation regions in large scale utility boiler
title_full CFD based identification of clinker formation regions in large scale utility boiler
title_fullStr CFD based identification of clinker formation regions in large scale utility boiler
title_full_unstemmed CFD based identification of clinker formation regions in large scale utility boiler
title_short CFD based identification of clinker formation regions in large scale utility boiler
title_sort cfd based identification of clinker formation regions in large scale utility boiler
url http://hdl.handle.net/20.500.11937/35570