Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis

A new aging calculation method for three-phase three-leg power transformers under (un)balanced and (non)sinusoidal operating conditions is proposed where the impacts of magnetic saturation, couplings, and hysteresis are accurately included. The aging estimation is carried out through a recently deve...

Full description

Bibliographic Details
Main Authors: Moses, Paul, Masoum, Mohammad
Format: Journal Article
Published: IEEE 2012
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/3536
_version_ 1848744258907930624
author Moses, Paul
Masoum, Mohammad
author_facet Moses, Paul
Masoum, Mohammad
author_sort Moses, Paul
building Curtin Institutional Repository
collection Online Access
description A new aging calculation method for three-phase three-leg power transformers under (un)balanced and (non)sinusoidal operating conditions is proposed where the impacts of magnetic saturation, couplings, and hysteresis are accurately included. The aging estimation is carried out through a recently developed and validated time-domain model of a nonlinear three-phase three-leg transformer. The model outputs are used to compute aging based on Arrhenius' thermal reaction theory. The combined aging effects from transformer core asymmetry and load nonlinearity, as well as current and voltage harmonic interactions from nonsinusoidal input excitations and nonlinear loading are considered in the calculation. The model improves upon the conventional weighted harmonic factor (WHF) approach of aging estimation by direct evaluation of additional fundamental and harmonic losses generated by the iron-core, nonlinear loads, and terminal voltage distortions. The main contribution is a new transformer aging estimation method with wider applicability to three-phase transformers considering harmonic current-voltage interactions from unbalanced nonlinear loads, terminal voltage distortions and imbalances, as well as magnetic hysteresis and flux-coupling effects in asymmetric iron-core structures. Several case studies are presented for comparing the proposed model based aging method with the conventional WHF approach.
first_indexed 2025-11-14T05:58:37Z
format Journal Article
id curtin-20.500.11937-3536
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T05:58:37Z
publishDate 2012
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-35362017-09-13T14:44:01Z Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis Moses, Paul Masoum, Mohammad weighted harmonic factor (WHF) Arrhenius thermal reaction rate theory transformer and power quality Aging A new aging calculation method for three-phase three-leg power transformers under (un)balanced and (non)sinusoidal operating conditions is proposed where the impacts of magnetic saturation, couplings, and hysteresis are accurately included. The aging estimation is carried out through a recently developed and validated time-domain model of a nonlinear three-phase three-leg transformer. The model outputs are used to compute aging based on Arrhenius' thermal reaction theory. The combined aging effects from transformer core asymmetry and load nonlinearity, as well as current and voltage harmonic interactions from nonsinusoidal input excitations and nonlinear loading are considered in the calculation. The model improves upon the conventional weighted harmonic factor (WHF) approach of aging estimation by direct evaluation of additional fundamental and harmonic losses generated by the iron-core, nonlinear loads, and terminal voltage distortions. The main contribution is a new transformer aging estimation method with wider applicability to three-phase transformers considering harmonic current-voltage interactions from unbalanced nonlinear loads, terminal voltage distortions and imbalances, as well as magnetic hysteresis and flux-coupling effects in asymmetric iron-core structures. Several case studies are presented for comparing the proposed model based aging method with the conventional WHF approach. 2012 Journal Article http://hdl.handle.net/20.500.11937/3536 10.1109/TEC.2011.2181949 IEEE restricted
spellingShingle weighted harmonic factor (WHF)
Arrhenius thermal reaction rate theory
transformer and power quality
Aging
Moses, Paul
Masoum, Mohammad
Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
title Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
title_full Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
title_fullStr Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
title_full_unstemmed Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
title_short Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
title_sort three-phase asymmetric transformer aging considering voltage-current harmonic interactions, unbalanced nonlinear loading, magnetic couplings and hysteresis
topic weighted harmonic factor (WHF)
Arrhenius thermal reaction rate theory
transformer and power quality
Aging
url http://hdl.handle.net/20.500.11937/3536