Variability of blood lactate during and between given constant prolonged cycling power

Aim. Blood lactate concentration (BLC) has been the basis of rational performance diagnostics for almost five decades. Aim of this study was to identify the variability of the BLC during repeated constant power tests (VC-BLC) and to quantify the corresponding variability of changes in the BLC over t...

Full description

Bibliographic Details
Main Authors: Melloh, Markus, Theis, J., Beneke, R.
Format: Journal Article
Published: 2012
Online Access:http://hdl.handle.net/20.500.11937/35275
_version_ 1848754452559822848
author Melloh, Markus
Theis, J.
Beneke, R.
author_facet Melloh, Markus
Theis, J.
Beneke, R.
author_sort Melloh, Markus
building Curtin Institutional Repository
collection Online Access
description Aim. Blood lactate concentration (BLC) has been the basis of rational performance diagnostics for almost five decades. Aim of this study was to identify the variability of the BLC during repeated constant power tests (VC-BLC) and to quantify the corresponding variability of changes in the BLC over time (VC-BLC-Difference). Methods. Twelve healthy male subjects (24.8±3-8 years, 182.9±7.5 cm, 75.7±7.1 kg,VO 2peak: 4.1±0.61 min-1) performed four series of three constant power tests at exercise intensities of 45% (A), 60% (B), 75% (C) and 90% (D) of VO2peak. Blood sampling was conducted before, at the end of every 5th min and at the end of each test terminated ahead of schedule. Results. BLC was different at all exercise intensities from minute five onwards. Power output was equivalent to 142.1±18.9 W (A), 196.3±25.2 W (B), 247.9±30.3 W (C) and 302.5±38.4 W (D). VC-BLC varied between 9±2.2% and 21±10.1%. VC-BLC and VC-BLC-Difference between 10th and 30th min correlated inversely with mean BLC level and BLC-Difference respectively. Conclusion. By providing first data on constant power test VC-BLC and VC-BLC-Difference this study might help to improve performance diagnostics and training control in sports medicine and medical exercise therapy by assisting in selecting and monitoring exercise intensity. Performance monitoring with BLC-Differences is feasible at moderate and high exercise intensities; single BLC measurements at termination of tests might not be sufficient.
first_indexed 2025-11-14T08:40:38Z
format Journal Article
id curtin-20.500.11937-35275
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:40:38Z
publishDate 2012
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-352752017-01-30T13:48:45Z Variability of blood lactate during and between given constant prolonged cycling power Melloh, Markus Theis, J. Beneke, R. Aim. Blood lactate concentration (BLC) has been the basis of rational performance diagnostics for almost five decades. Aim of this study was to identify the variability of the BLC during repeated constant power tests (VC-BLC) and to quantify the corresponding variability of changes in the BLC over time (VC-BLC-Difference). Methods. Twelve healthy male subjects (24.8±3-8 years, 182.9±7.5 cm, 75.7±7.1 kg,VO 2peak: 4.1±0.61 min-1) performed four series of three constant power tests at exercise intensities of 45% (A), 60% (B), 75% (C) and 90% (D) of VO2peak. Blood sampling was conducted before, at the end of every 5th min and at the end of each test terminated ahead of schedule. Results. BLC was different at all exercise intensities from minute five onwards. Power output was equivalent to 142.1±18.9 W (A), 196.3±25.2 W (B), 247.9±30.3 W (C) and 302.5±38.4 W (D). VC-BLC varied between 9±2.2% and 21±10.1%. VC-BLC and VC-BLC-Difference between 10th and 30th min correlated inversely with mean BLC level and BLC-Difference respectively. Conclusion. By providing first data on constant power test VC-BLC and VC-BLC-Difference this study might help to improve performance diagnostics and training control in sports medicine and medical exercise therapy by assisting in selecting and monitoring exercise intensity. Performance monitoring with BLC-Differences is feasible at moderate and high exercise intensities; single BLC measurements at termination of tests might not be sufficient. 2012 Journal Article http://hdl.handle.net/20.500.11937/35275 restricted
spellingShingle Melloh, Markus
Theis, J.
Beneke, R.
Variability of blood lactate during and between given constant prolonged cycling power
title Variability of blood lactate during and between given constant prolonged cycling power
title_full Variability of blood lactate during and between given constant prolonged cycling power
title_fullStr Variability of blood lactate during and between given constant prolonged cycling power
title_full_unstemmed Variability of blood lactate during and between given constant prolonged cycling power
title_short Variability of blood lactate during and between given constant prolonged cycling power
title_sort variability of blood lactate during and between given constant prolonged cycling power
url http://hdl.handle.net/20.500.11937/35275