An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance

Locomotives in heavy haul and high speed passenger operations represent several megawatts of electrical load. Single phase power collected by a pantograph is typically rectified by multiple PWM converters. The converter switching instants are phased to ensure ripple current cancellation, assuming th...

Full description

Bibliographic Details
Main Authors: Kuppa, V., Wolfs, Peter, Senini, S.
Other Authors: Michael Negnvitsky
Format: Conference Paper
Published: University of Tasmania 2005
Online Access:http://hdl.handle.net/20.500.11937/33744
_version_ 1848754032074555392
author Kuppa, V.
Wolfs, Peter
Senini, S.
author2 Michael Negnvitsky
author_facet Michael Negnvitsky
Kuppa, V.
Wolfs, Peter
Senini, S.
author_sort Kuppa, V.
building Curtin Institutional Repository
collection Online Access
description Locomotives in heavy haul and high speed passenger operations represent several megawatts of electrical load. Single phase power collected by a pantograph is typically rectified by multiple PWM converters. The converter switching instants are phased to ensure ripple current cancellation, assuming that the converter loads are balanced. Partial failures may result in unbalanced operation with reduced cancellation. The resulting harmonics may adversely impact the signalling systems and/or result in over voltage effects due to resonance in the overhead supply system. This paper examines a 4MW locomotive with three rectifier modules and a device switching frequency of 900 Hz. This results in a 5400 Hz ripple frequency in the mains current. Ideal balanced operation of converters is compared to an unbalanced operation case. Unbalanced cases include rectifier failures, inverter failures and changes in the relative balance of power delivered to each axle of the locomotive. This paper will consider what may be the most frequently occurring case; that of loss of load in one traction motor due to wheel slip. Current ripple cancellation is partially lost in this case and lower frequency current components can be produced. An active filter is proposed as a means to retain an acceptable harmonic performance for the locomotive.
first_indexed 2025-11-14T08:33:57Z
format Conference Paper
id curtin-20.500.11937-33744
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:33:57Z
publishDate 2005
publisher University of Tasmania
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-337442017-10-02T02:27:57Z An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance Kuppa, V. Wolfs, Peter Senini, S. Michael Negnvitsky Locomotives in heavy haul and high speed passenger operations represent several megawatts of electrical load. Single phase power collected by a pantograph is typically rectified by multiple PWM converters. The converter switching instants are phased to ensure ripple current cancellation, assuming that the converter loads are balanced. Partial failures may result in unbalanced operation with reduced cancellation. The resulting harmonics may adversely impact the signalling systems and/or result in over voltage effects due to resonance in the overhead supply system. This paper examines a 4MW locomotive with three rectifier modules and a device switching frequency of 900 Hz. This results in a 5400 Hz ripple frequency in the mains current. Ideal balanced operation of converters is compared to an unbalanced operation case. Unbalanced cases include rectifier failures, inverter failures and changes in the relative balance of power delivered to each axle of the locomotive. This paper will consider what may be the most frequently occurring case; that of loss of load in one traction motor due to wheel slip. Current ripple cancellation is partially lost in this case and lower frequency current components can be produced. An active filter is proposed as a means to retain an acceptable harmonic performance for the locomotive. 2005 Conference Paper http://hdl.handle.net/20.500.11937/33744 University of Tasmania fulltext
spellingShingle Kuppa, V.
Wolfs, Peter
Senini, S.
An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance
title An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance
title_full An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance
title_fullStr An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance
title_full_unstemmed An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance
title_short An Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance
title_sort active power filter method to improve the line current spectrum of pwm locomotive rectifiers with load unbalance
url http://hdl.handle.net/20.500.11937/33744