Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2

Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly upgrading softwares and adding new features in their Intelligent Electronic Devices (IED&...

Full description

Bibliographic Details
Main Authors: Kumar, S., Das, N., Islam, Syed
Format: Conference Paper
Published: 2016
Online Access:http://hdl.handle.net/20.500.11937/33270
_version_ 1848753898783768576
author Kumar, S.
Das, N.
Islam, Syed
author_facet Kumar, S.
Das, N.
Islam, Syed
author_sort Kumar, S.
building Curtin Institutional Repository
collection Online Access
description Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly upgrading softwares and adding new features in their Intelligent Electronic Devices (IED's) to carry out multiple functions in process bus devices. This paper presents simulation results with respect to the delay in packets transfer in an Ethernet environment. Understanding the delay in packet transfer of Generic Object Oriented Substation Event (GOOSE) and Sampled Values (SV) shall assist the user in understanding the substation automation, control and protection of substation primary plants such as current transformers (CT's), voltage transformers (VT's), circuit breakers etc. connected in the network during a fault condition Conventional substation uses Merging Units (MU's) to communicate with the IED's featuring IEC 61850-9-2 standard. This standard exhibits transparency and standardization of data communication while addressing issues related to reliability, packet sharing, and maintainability, etc. However, process bus architecture is yet to be widely accepted in the industry and needs further validation due to lack of confidence. This paper evaluates the performance of a digital protection scheme in a zone substation operating at 132kV, featuring IEC 61850-9-2 IED's and using an optimized network engineering tool (OPNET) simulator. Understanding the delay in receiving time critical GOOSE and sampled value SV messages from protection perspective is critical as loss of data could cause malfunction in the protection jeopardizing vital substation plants.
first_indexed 2025-11-14T08:31:50Z
format Conference Paper
id curtin-20.500.11937-33270
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:31:50Z
publishDate 2016
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-332702018-03-29T09:08:49Z Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2 Kumar, S. Das, N. Islam, Syed Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly upgrading softwares and adding new features in their Intelligent Electronic Devices (IED's) to carry out multiple functions in process bus devices. This paper presents simulation results with respect to the delay in packets transfer in an Ethernet environment. Understanding the delay in packet transfer of Generic Object Oriented Substation Event (GOOSE) and Sampled Values (SV) shall assist the user in understanding the substation automation, control and protection of substation primary plants such as current transformers (CT's), voltage transformers (VT's), circuit breakers etc. connected in the network during a fault condition Conventional substation uses Merging Units (MU's) to communicate with the IED's featuring IEC 61850-9-2 standard. This standard exhibits transparency and standardization of data communication while addressing issues related to reliability, packet sharing, and maintainability, etc. However, process bus architecture is yet to be widely accepted in the industry and needs further validation due to lack of confidence. This paper evaluates the performance of a digital protection scheme in a zone substation operating at 132kV, featuring IEC 61850-9-2 IED's and using an optimized network engineering tool (OPNET) simulator. Understanding the delay in receiving time critical GOOSE and sampled value SV messages from protection perspective is critical as loss of data could cause malfunction in the protection jeopardizing vital substation plants. 2016 Conference Paper http://hdl.handle.net/20.500.11937/33270 10.1109/APPEEC.2015.7381017 restricted
spellingShingle Kumar, S.
Das, N.
Islam, Syed
Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
title Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
title_full Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
title_fullStr Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
title_full_unstemmed Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
title_short Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
title_sort performance evaluation of a process bus architecture in a zone substation based on iec 61850-9-2
url http://hdl.handle.net/20.500.11937/33270