Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits

Background; People with neuromuscular disorders (NMD) exhibit weak coughs and are susceptible to recurrent chest infections and acute respiratory complications, the most frequent reasons for their unplanned hospital admissions. Mechanical insufflation-exsufflation (MI-E) devices are a non-invasive m...

Full description

Bibliographic Details
Main Authors: Mahede, T., Davis, G., Rutkay, A., Baxendale, S., Sun, W., Dawkins, Hugh, Molster, C., Graham, C.
Format: Journal Article
Published: BioMed Central Ltd. 2015
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/32120
_version_ 1848753573324652544
author Mahede, T.
Davis, G.
Rutkay, A.
Baxendale, S.
Sun, W.
Dawkins, Hugh
Molster, C.
Graham, C.
author_facet Mahede, T.
Davis, G.
Rutkay, A.
Baxendale, S.
Sun, W.
Dawkins, Hugh
Molster, C.
Graham, C.
author_sort Mahede, T.
building Curtin Institutional Repository
collection Online Access
description Background; People with neuromuscular disorders (NMD) exhibit weak coughs and are susceptible to recurrent chest infections and acute respiratory complications, the most frequent reasons for their unplanned hospital admissions. Mechanical insufflation-exsufflation (MI-E) devices are a non-invasive method of increasing peak cough flow, improving cough efficacy, the clearance of secretion and overcoming atelectasis. There is limited published evidence on the impact of home use MI-E devices on health service utilisation. The aims of the study were: to assess the self-reported health and lifestyle benefits experienced as a result of home use of MI-E devices; and evaluate the effects of in-home use of MI-E devices on Emergency Department (ED) presentations, hospital admissions and inpatient length of stay (LOS). Methods: Individuals with NMD who were accessing a home MI-E device provided through Muscular Dystrophy Western Australia were invited to participate in a quantitative survey to obtain information on their experiences and self-assessed changes in respiratory health. An ad-hoc record linkage was performed to extract hospital, ED and mortality data from the Western Australian Department of Health (DOHWA). The main outcome measures were ED presentations, hospital separations and LOS, before and after commencement of home use of an MI-E device.Results: Thirty seven individuals with NMD using a MI-E device at home consented to participate in this study. The majority (73%) of participants reported using the MI-E device daily or weekly at home without medical assistance and 32% had used the machine to resolve a choking episode. The survey highlighted benefits to respiratory function maintenance and the ability to manage increased health care needs at home. Not using a home MI-E device was associated with an increased risk of ED presentations (RR = 1.76, 95% CI 1.1-2.84). The number of hospital separations and LOS reduced after the use of MI-E device, but not significantly. No deaths were observed in participants using the MI-E device at home. Conclusions: Home use of a MI-E device by people living with NMD may have a potential impact on reducing their health service utilisation and risk of death. Future research with greater subject numbers and longer follow-up periods is recommended to enhance this field of study.
first_indexed 2025-11-14T08:26:40Z
format Journal Article
id curtin-20.500.11937-32120
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:26:40Z
publishDate 2015
publisher BioMed Central Ltd.
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-321202018-04-09T07:02:11Z Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits Mahede, T. Davis, G. Rutkay, A. Baxendale, S. Sun, W. Dawkins, Hugh Molster, C. Graham, C. Muscular - dystrophy Neuromuscular disorder Cough Respiratory clearance Mechanical in-exsufflation Background; People with neuromuscular disorders (NMD) exhibit weak coughs and are susceptible to recurrent chest infections and acute respiratory complications, the most frequent reasons for their unplanned hospital admissions. Mechanical insufflation-exsufflation (MI-E) devices are a non-invasive method of increasing peak cough flow, improving cough efficacy, the clearance of secretion and overcoming atelectasis. There is limited published evidence on the impact of home use MI-E devices on health service utilisation. The aims of the study were: to assess the self-reported health and lifestyle benefits experienced as a result of home use of MI-E devices; and evaluate the effects of in-home use of MI-E devices on Emergency Department (ED) presentations, hospital admissions and inpatient length of stay (LOS). Methods: Individuals with NMD who were accessing a home MI-E device provided through Muscular Dystrophy Western Australia were invited to participate in a quantitative survey to obtain information on their experiences and self-assessed changes in respiratory health. An ad-hoc record linkage was performed to extract hospital, ED and mortality data from the Western Australian Department of Health (DOHWA). The main outcome measures were ED presentations, hospital separations and LOS, before and after commencement of home use of an MI-E device.Results: Thirty seven individuals with NMD using a MI-E device at home consented to participate in this study. The majority (73%) of participants reported using the MI-E device daily or weekly at home without medical assistance and 32% had used the machine to resolve a choking episode. The survey highlighted benefits to respiratory function maintenance and the ability to manage increased health care needs at home. Not using a home MI-E device was associated with an increased risk of ED presentations (RR = 1.76, 95% CI 1.1-2.84). The number of hospital separations and LOS reduced after the use of MI-E device, but not significantly. No deaths were observed in participants using the MI-E device at home. Conclusions: Home use of a MI-E device by people living with NMD may have a potential impact on reducing their health service utilisation and risk of death. Future research with greater subject numbers and longer follow-up periods is recommended to enhance this field of study. 2015 Journal Article http://hdl.handle.net/20.500.11937/32120 10.1186/s13023-015-0267-0 http://creativecommons.org/licenses/by/4.0 BioMed Central Ltd. fulltext
spellingShingle Muscular - dystrophy
Neuromuscular disorder
Cough
Respiratory clearance
Mechanical in-exsufflation
Mahede, T.
Davis, G.
Rutkay, A.
Baxendale, S.
Sun, W.
Dawkins, Hugh
Molster, C.
Graham, C.
Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits
title Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits
title_full Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits
title_fullStr Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits
title_full_unstemmed Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits
title_short Use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits
title_sort use of mechanical airway clearance devices in the home by people with neuromuscular disorders: effects on health service use and lifestyle benefits
topic Muscular - dystrophy
Neuromuscular disorder
Cough
Respiratory clearance
Mechanical in-exsufflation
url http://hdl.handle.net/20.500.11937/32120