Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor

Landfill leachate contains a high concentration of organic pollutants that are active agents in water pollution. This study was conducted to remove various pollutants from landfill leachate through electrolysis and activated carbon (AC) treatments. A simple electrolytic reactor was designed to inves...

Full description

Bibliographic Details
Main Authors: Ahsan, A., Kamaludin, M., Rahman, M., Anwar, Faisal, Bek, M., Idrus, S.
Format: Journal Article
Published: Springer Netherlands 2014
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/3195
_version_ 1848744165006901248
author Ahsan, A.
Kamaludin, M.
Rahman, M.
Anwar, Faisal
Bek, M.
Idrus, S.
author_facet Ahsan, A.
Kamaludin, M.
Rahman, M.
Anwar, Faisal
Bek, M.
Idrus, S.
author_sort Ahsan, A.
building Curtin Institutional Repository
collection Online Access
description Landfill leachate contains a high concentration of organic pollutants that are active agents in water pollution. This study was conducted to remove various pollutants from landfill leachate through electrolysis and activated carbon (AC) treatments. A simple electrolytic reactor was designed to investigate the removal efficiency of these treatments for biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSSs), and total dissolved solids (TDSs) from landfill leachate at different electric current densities (CDs) and retention times (RTs). The results showed that the highest removal efficiencies for BOD and COD were 75.6 and 57 %, respectively, under a 7-V current for 4 h. It was also found that BOD, COD, TSS, and TDS removal efficiencies improved in proportion to an increase in CD and RT. However, pH gradually increased with an increase in CD and RT. A number of treated leachate samples were further polished by AC filtration to compare the effect of this additional process on the removal of color, BOD, COD, TSS, and TDS. This secondary treatment resulted in a higher removal of color and other pollutants than electrolysis alone. At 4 h RT, the BOD removal efficiency was 54.6 % at 3 V and 66.4 % at 5 V, and the efficiency increased to 61.5 and 70.5 %, respectively, after treatment by AC filtration. Under the same conditions, COD removal efficiency increased from 7.5 to 38.5 % at 3 V and from 31.1 to 49.5 % at 5 V. TSS and TDS removal efficiencies were also significantly improved by AC filtration. It is therefore concluded that 7 V of CD and 4 h of RT are the optimum parameters for removing pollutants from leachate and that the secondary treatment of AC filtration is an efficient method of further polishing.
first_indexed 2025-11-14T05:57:07Z
format Journal Article
id curtin-20.500.11937-3195
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T05:57:07Z
publishDate 2014
publisher Springer Netherlands
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-31952017-09-13T14:44:02Z Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor Ahsan, A. Kamaludin, M. Rahman, M. Anwar, Faisal Bek, M. Idrus, S. Leachate Pollutants Activated carbon Electrolysis BOD Landfill leachate contains a high concentration of organic pollutants that are active agents in water pollution. This study was conducted to remove various pollutants from landfill leachate through electrolysis and activated carbon (AC) treatments. A simple electrolytic reactor was designed to investigate the removal efficiency of these treatments for biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSSs), and total dissolved solids (TDSs) from landfill leachate at different electric current densities (CDs) and retention times (RTs). The results showed that the highest removal efficiencies for BOD and COD were 75.6 and 57 %, respectively, under a 7-V current for 4 h. It was also found that BOD, COD, TSS, and TDS removal efficiencies improved in proportion to an increase in CD and RT. However, pH gradually increased with an increase in CD and RT. A number of treated leachate samples were further polished by AC filtration to compare the effect of this additional process on the removal of color, BOD, COD, TSS, and TDS. This secondary treatment resulted in a higher removal of color and other pollutants than electrolysis alone. At 4 h RT, the BOD removal efficiency was 54.6 % at 3 V and 66.4 % at 5 V, and the efficiency increased to 61.5 and 70.5 %, respectively, after treatment by AC filtration. Under the same conditions, COD removal efficiency increased from 7.5 to 38.5 % at 3 V and from 31.1 to 49.5 % at 5 V. TSS and TDS removal efficiencies were also significantly improved by AC filtration. It is therefore concluded that 7 V of CD and 4 h of RT are the optimum parameters for removing pollutants from leachate and that the secondary treatment of AC filtration is an efficient method of further polishing. 2014 Journal Article http://hdl.handle.net/20.500.11937/3195 10.1007/s11270-014-2163-y Springer Netherlands restricted
spellingShingle Leachate
Pollutants
Activated carbon
Electrolysis
BOD
Ahsan, A.
Kamaludin, M.
Rahman, M.
Anwar, Faisal
Bek, M.
Idrus, S.
Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor
title Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor
title_full Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor
title_fullStr Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor
title_full_unstemmed Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor
title_short Removal of Various Pollutants from Leachate Using a Low-Cost Technique: Integration of Electrolysis with Activated Carbon Contactor
title_sort removal of various pollutants from leachate using a low-cost technique: integration of electrolysis with activated carbon contactor
topic Leachate
Pollutants
Activated carbon
Electrolysis
BOD
url http://hdl.handle.net/20.500.11937/3195