Impact of balanced and unbalanced direct current bias on harmonic distortion generated by asymmetric three-phase three-leg transformers
The impacts of dc bias and (un)balanced operation including tank effects on harmonic distortions generated by three-phase three-leg transformers are studied. Phase imbalances in power networks can arise from unbalanced loads, imperfections in the transposition of long transmission lines and asymmetr...
| Main Authors: | Masoum, Mohammad Sherkat, Moses, Paul |
|---|---|
| Format: | Journal Article |
| Published: |
Institution of Engineering and Technology
2010
|
| Online Access: | http://hdl.handle.net/20.500.11937/28548 |
Similar Items
Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
by: Moses, Paul, et al.
Published: (2012)
by: Moses, Paul, et al.
Published: (2012)
Distortions in Three-Phase Transformer Magnetizing Currents with Nonsinusoidal Conditions Considering Magnetic Hysteresis and Leg-Flux Coupling Effects
by: Moses, Paul, et al.
Published: (2011)
by: Moses, Paul, et al.
Published: (2011)
Derating of asymmetric three-phase transformers serving unbalanced nonlinear loads
by: Masoum, Mohammad, et al.
Published: (2008)
by: Masoum, Mohammad, et al.
Published: (2008)
Impacts of Hysteresis and Magnetic Couplings on the Stability Domain of Ferroresonance in Asymmetric Three-Phase Three-Leg Transformers
by: Moses, Paul, et al.
Published: (2011)
by: Moses, Paul, et al.
Published: (2011)
Load Management in Smart Grids Considering Harmonic Distortion and Transformer Derating
by: Masoum, Mohammad Sherkat, et al.
Published: (2010)
by: Masoum, Mohammad Sherkat, et al.
Published: (2010)
Modeling Ferroresonance in Asymmetric Three-Phase Power Transformers
by: Moses, Paul, et al.
Published: (2009)
by: Moses, Paul, et al.
Published: (2009)
Effects of Iron-Core Topology on Inrush Currents in Three-Phase Multi-Leg Power Transformers
by: Moses, Paul, et al.
Published: (2012)
by: Moses, Paul, et al.
Published: (2012)
Analysis and Comparison of Bus Ranking Indices for Balanced and Unbalanced Three-Phase Distribution Networks
by: Juanuwattanakul, Parachai, et al.
Published: (2011)
by: Juanuwattanakul, Parachai, et al.
Published: (2011)
Distribution transformer loading in unbalanced three-phase residential networks with random charging of plug-in electric vehicles
by: Moghbel, Moayed, et al.
Published: (2012)
by: Moghbel, Moayed, et al.
Published: (2012)
Harmonic distortion performance of multi three-phase SCR-fed drive systems with controlled DC-link current under unbalanced grid
by: Soltani, H., et al.
Published: (2017)
by: Soltani, H., et al.
Published: (2017)
Operation and performance of three-phase asymmetric multi-leg power transformers subjected to nonlinear and dynamic electromagnetic disturbances
by: Moses, Paul S.
Published: (2012)
by: Moses, Paul S.
Published: (2012)
Dynamic Modeling of Three-Phase Asymmetric Power Transformers with Magnetic Hysteresis: No-Load and Inrush Conditions
by: Moses, Paul, et al.
Published: (2010)
by: Moses, Paul, et al.
Published: (2010)
Harmonic losses and stresses of nonlinear three-phase distribution transformers serving Plug-In Electric Vehicle charging stations
by: Moses, Paul, et al.
Published: (2011)
by: Moses, Paul, et al.
Published: (2011)
Influence of Geomagnetically Induced Currents on Three-Phase Power Transformers
by: Masoum, Mohammad, et al.
Published: (2008)
by: Masoum, Mohammad, et al.
Published: (2008)
Coordinated charging of plug-in electric vehicles in unbalanced three-phase residential networks with smart three-phase charger
by: Masoum, Mohammad Sherkat, et al.
Published: (2014)
by: Masoum, Mohammad Sherkat, et al.
Published: (2014)
Reusing three-phase power-flow object components for unbalanced harmonic analysis
by: Nor, Khaled Mohamed, et al.
Published: (2006)
by: Nor, Khaled Mohamed, et al.
Published: (2006)
PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
by: Hoon, Yap, et al.
Published: (2018)
by: Hoon, Yap, et al.
Published: (2018)
New technique for decreasing of total harmonic distortion of three- phases bridge rectifier by using the method of harmonic injection
by: Al-Ogaili, Ali Saadon Mtair, et al.
Published: (2016)
by: Al-Ogaili, Ali Saadon Mtair, et al.
Published: (2016)
Coordination of single-phase rooftop PVs in unbalanced three-phase residential feeders for voltage profiles improvement
by: Safitri, N., et al.
Published: (2015)
by: Safitri, N., et al.
Published: (2015)
The three phase rectifier with harmonic injection current
by: Misron, Norhisam, et al.
Published: (2010)
by: Misron, Norhisam, et al.
Published: (2010)
Derating active power filters considering network and bus voltage total harmonic distortions
by: Deilami, Sara, et al.
Published: (2016)
by: Deilami, Sara, et al.
Published: (2016)
Comparison of Compensation Strategies for Shunt Active Power Filter Control in Unbalanced Three-Phase Four-Wire Systems
by: Ranjbar, M., et al.
Published: (2009)
by: Ranjbar, M., et al.
Published: (2009)
Optimal operation of multiple unbalanced distributed generation sources in three-phase four-wire LV distribution networks
by: Su, Xiangjing, et al.
Published: (2012)
by: Su, Xiangjing, et al.
Published: (2012)
Comprehensive optimal photovoltaic inverter control strategy in unbalanced three-phase four-wire low voltage distribution networks
by: Su, Xiangjing, et al.
Published: (2014)
by: Su, Xiangjing, et al.
Published: (2014)
Impact of Voltage Sags on Three-Phase Power Transformers
by: Masoum, Ali, et al.
Published: (2010)
by: Masoum, Ali, et al.
Published: (2010)
Voltage Profile and THD Distortion of Residential Network with High Penetration of Plug-in Electrical Vehicles
by: Deilami, Sara, et al.
Published: (2010)
by: Deilami, Sara, et al.
Published: (2010)
Online Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements Considering Impact of Harmonics
by: Masoum, A., et al.
Published: (2017)
by: Masoum, A., et al.
Published: (2017)
Impact of Harmonics on the Performance of Over-Current Relays
by: Tin, Hillary, et al.
Published: (2011)
by: Tin, Hillary, et al.
Published: (2011)
Analysis of three-phase rectifier systems with controlled DC-link current under unbalanced grids
by: Kumar, D., et al.
Published: (2017)
by: Kumar, D., et al.
Published: (2017)
Torques in Induction Machines Due to Low-Frequency Voltage/Current Harmonics
by: Fuchs, E., et al.
Published: (2008)
by: Fuchs, E., et al.
Published: (2008)
Hybrid Genetic-fuzzy Algorithm for volt/var/total Harmonic Distortion Control of Distribution Systems with High Penetration of Non-Linear Loads
by: Ulinuha, A., et al.
Published: (2011)
by: Ulinuha, A., et al.
Published: (2011)
Analysis and design of an unbalanced input three phase controlled rectifier
by: Islam Khan, Shahidul, et al.
Published: (1997)
by: Islam Khan, Shahidul, et al.
Published: (1997)
Analysis and design of an unbalanced input three phase controlled rectifier
by: Khan, S. I., et al.
Published: (1997)
by: Khan, S. I., et al.
Published: (1997)
Impact of a SG Nonlinear Model on the Harmonic Distortion of a Distribution Generation System
by: Ladjavardi, Marjan, et al.
Published: (2008)
by: Ladjavardi, Marjan, et al.
Published: (2008)
Var compensation by evolutionary programming considering unbalanced load and multiple harmonics in source voltage and load current
by: Pau, K. N., et al.
Published: (2009)
by: Pau, K. N., et al.
Published: (2009)
Odd and total harmonic insulator distortion of leakage current as a tool to estimate contamination level
by: Salem, Ali Ahmed, et al.
Published: (2020)
by: Salem, Ali Ahmed, et al.
Published: (2020)
A Novel Current Regulator for DFIG Wind Turbines with Enhanced Performance under Unbalanced Supply Voltage Condition
by: Mohseni, Mansour, et al.
Published: (2010)
by: Mohseni, Mansour, et al.
Published: (2010)
Power flow solution of three-phase unbalanced radial distribution network
by: Ranjan, R., et al.
Published: (2004)
by: Ranjan, R., et al.
Published: (2004)
PLL-less SRF technique for operation of SAPF under unbalanced and distorted supply voltage
by: Hoon, Yap, et al.
Published: (2018)
by: Hoon, Yap, et al.
Published: (2018)
Predictive pulse-pattern current modulation scheme for harmonic reduction in three-phase multidrive systems
by: Davari, P., et al.
Published: (2016)
by: Davari, P., et al.
Published: (2016)
Similar Items
-
Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings and Hysteresis
by: Moses, Paul, et al.
Published: (2012) -
Distortions in Three-Phase Transformer Magnetizing Currents with Nonsinusoidal Conditions Considering Magnetic Hysteresis and Leg-Flux Coupling Effects
by: Moses, Paul, et al.
Published: (2011) -
Derating of asymmetric three-phase transformers serving unbalanced nonlinear loads
by: Masoum, Mohammad, et al.
Published: (2008) -
Impacts of Hysteresis and Magnetic Couplings on the Stability Domain of Ferroresonance in Asymmetric Three-Phase Three-Leg Transformers
by: Moses, Paul, et al.
Published: (2011) -
Load Management in Smart Grids Considering Harmonic Distortion and Transformer Derating
by: Masoum, Mohammad Sherkat, et al.
Published: (2010)