Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid

As a result of the toxic and corrosive nature of chlorine gas, simple methods for its detection are required for monitoring and control purposes. In this paper, the electrochemical behavior of chlorine on platinum working electrodes in the room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazo...

Full description

Bibliographic Details
Main Authors: Murugappan, Krishnan, Arrigan, Damien, Silvester, Debbie
Format: Journal Article
Published: 2015
Online Access:http://purl.org/au-research/grants/arc/DE120101456
http://hdl.handle.net/20.500.11937/28082
_version_ 1848752440062509056
author Murugappan, Krishnan
Arrigan, Damien
Silvester, Debbie
author_facet Murugappan, Krishnan
Arrigan, Damien
Silvester, Debbie
author_sort Murugappan, Krishnan
building Curtin Institutional Repository
collection Online Access
description As a result of the toxic and corrosive nature of chlorine gas, simple methods for its detection are required for monitoring and control purposes. In this paper, the electrochemical behavior of chlorine on platinum working electrodes in the room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]) is reported, as a basis for simple sensor devices. Cyclic voltammetry (CV) and chronoamperometry (CA) on a Pt microelectrode revealed the two-electron reduction of Cl2 to chloride ions. On the CV reverse sweep, an oxidation peak due to the oxidation of chloride was observed. The reduction process was diffusion controlled at the concentrations studied (≤4.5% in the gas phase), in contrast to a previous report (J. Phys. Chem. C2008, 112, 19477), which examined only 100% chlorine. The diffusion-controlled currents were linear with gas-phase concentration. Fitting of the CA transients to the Shoup and Szabo expression gave a diffusion coefficient for chlorine in the RTIL of ca. 2.6 × 10–10 m2 s–1. Furthermore, determination of the equilibrium concentration of Cl2 in the RTIL phase as a function of gas-phase concentration enabled a value of 35 to be determined for the Henry’s law dimensionless volatility constant. The electrochemical behavior of chlorine on a Pt screen-printed electrode was also investigated, suggesting that these devices may be useful for chlorine detection in conjunction with suitable RTILs.
first_indexed 2025-11-14T08:08:39Z
format Journal Article
id curtin-20.500.11937-28082
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T08:08:39Z
publishDate 2015
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-280822019-02-19T05:35:23Z Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid Murugappan, Krishnan Arrigan, Damien Silvester, Debbie As a result of the toxic and corrosive nature of chlorine gas, simple methods for its detection are required for monitoring and control purposes. In this paper, the electrochemical behavior of chlorine on platinum working electrodes in the room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]) is reported, as a basis for simple sensor devices. Cyclic voltammetry (CV) and chronoamperometry (CA) on a Pt microelectrode revealed the two-electron reduction of Cl2 to chloride ions. On the CV reverse sweep, an oxidation peak due to the oxidation of chloride was observed. The reduction process was diffusion controlled at the concentrations studied (≤4.5% in the gas phase), in contrast to a previous report (J. Phys. Chem. C2008, 112, 19477), which examined only 100% chlorine. The diffusion-controlled currents were linear with gas-phase concentration. Fitting of the CA transients to the Shoup and Szabo expression gave a diffusion coefficient for chlorine in the RTIL of ca. 2.6 × 10–10 m2 s–1. Furthermore, determination of the equilibrium concentration of Cl2 in the RTIL phase as a function of gas-phase concentration enabled a value of 35 to be determined for the Henry’s law dimensionless volatility constant. The electrochemical behavior of chlorine on a Pt screen-printed electrode was also investigated, suggesting that these devices may be useful for chlorine detection in conjunction with suitable RTILs. 2015 Journal Article http://hdl.handle.net/20.500.11937/28082 10.1021/acs.jpcc.5b07753 http://purl.org/au-research/grants/arc/DE120101456 fulltext
spellingShingle Murugappan, Krishnan
Arrigan, Damien
Silvester, Debbie
Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid
title Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid
title_full Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid
title_fullStr Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid
title_full_unstemmed Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid
title_short Electrochemical Behavior of Chlorine on Platinum Microdisk and Screen-Printed Electrodes in a Room Temperature Ionic Liquid
title_sort electrochemical behavior of chlorine on platinum microdisk and screen-printed electrodes in a room temperature ionic liquid
url http://purl.org/au-research/grants/arc/DE120101456
http://hdl.handle.net/20.500.11937/28082