Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5
Reliable protection, communication and control are the key features of a digital protection scheme in a utility substation. Microgrid is an alternative solution of installing long Transmission & Distribution lines could be cost prohibitive. There are number of Intelligent Electronic Devices (IED...
| Main Authors: | , , |
|---|---|
| Format: | Conference Paper |
| Published: |
2016
|
| Online Access: | http://hdl.handle.net/20.500.11937/26687 |
| _version_ | 1848752057406717952 |
|---|---|
| author | Kumar, S. Das, N. Islam, Syed |
| author_facet | Kumar, S. Das, N. Islam, Syed |
| author_sort | Kumar, S. |
| building | Curtin Institutional Repository |
| collection | Online Access |
| description | Reliable protection, communication and control are the key features of a digital protection scheme in a utility substation. Microgrid is an alternative solution of installing long Transmission & Distribution lines could be cost prohibitive. There are number of Intelligent Electronic Devices (IEDs) which could find applications in controlling and monitoring of power network in a Microgrid set up and one such device is Phasor Measurement Unit (PMU). It is a microprocessor based intelligent device which gathers high-resolution data, checks the power quality and records disturbances. However, few issues that remains to be addressed such as, interoperability in a multi-vendor equipment and coordination between individual control systems in an integrated scheme. In this paper, an Operational Network Technology (OPNET) software model of a PMU has been designed and tested for its performance in a Microgrid environment based on IEC 61850-90-5 standard. |
| first_indexed | 2025-11-14T08:02:34Z |
| format | Conference Paper |
| id | curtin-20.500.11937-26687 |
| institution | Curtin University Malaysia |
| institution_category | Local University |
| last_indexed | 2025-11-14T08:02:34Z |
| publishDate | 2016 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | curtin-20.500.11937-266872018-03-29T09:08:37Z Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5 Kumar, S. Das, N. Islam, Syed Reliable protection, communication and control are the key features of a digital protection scheme in a utility substation. Microgrid is an alternative solution of installing long Transmission & Distribution lines could be cost prohibitive. There are number of Intelligent Electronic Devices (IEDs) which could find applications in controlling and monitoring of power network in a Microgrid set up and one such device is Phasor Measurement Unit (PMU). It is a microprocessor based intelligent device which gathers high-resolution data, checks the power quality and records disturbances. However, few issues that remains to be addressed such as, interoperability in a multi-vendor equipment and coordination between individual control systems in an integrated scheme. In this paper, an Operational Network Technology (OPNET) software model of a PMU has been designed and tested for its performance in a Microgrid environment based on IEC 61850-90-5 standard. 2016 Conference Paper http://hdl.handle.net/20.500.11937/26687 10.1109/AUPEC.2016.7749356 restricted |
| spellingShingle | Kumar, S. Das, N. Islam, Syed Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5 |
| title | Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5 |
| title_full | Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5 |
| title_fullStr | Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5 |
| title_full_unstemmed | Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5 |
| title_short | Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5 |
| title_sort | performance monitoring of a pmu in a microgrid environment based on iec 61850-90-5 |
| url | http://hdl.handle.net/20.500.11937/26687 |