Different approaches to reduce shaft voltage in AC generators

This paper presents several shaft voltage reduction techniques for doubly-fed induction generators in wind turbine applications. These techniques includes: pulse width modulated voltage without zero vectors, multi-level inverters with proper PWM strategy, better generator design to minimize effectiv...

Full description

Bibliographic Details
Main Authors: zare, F., Abadi, J., Ghosh, Arindam
Other Authors: -
Format: Conference Paper
Published: 2009 13th European Conference on Power Electronics and Applications (EPE 2009) 2009
Online Access:http://hdl.handle.net/20.500.11937/25643
_version_ 1848751765982281728
author zare, F.
Abadi, J.
Ghosh, Arindam
author2 -
author_facet -
zare, F.
Abadi, J.
Ghosh, Arindam
author_sort zare, F.
building Curtin Institutional Repository
collection Online Access
description This paper presents several shaft voltage reduction techniques for doubly-fed induction generators in wind turbine applications. These techniques includes: pulse width modulated voltage without zero vectors, multi-level inverters with proper PWM strategy, better generator design to minimize effective capacitive couplings in shaft voltage, active common-mode filter, reducing DC-link voltage and increasing modulation index. These methods have been verified with mathematical analysis and simulations.
first_indexed 2025-11-14T07:57:56Z
format Conference Paper
id curtin-20.500.11937-25643
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:57:56Z
publishDate 2009
publisher 2009 13th European Conference on Power Electronics and Applications (EPE 2009)
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-256432017-02-28T01:43:50Z Different approaches to reduce shaft voltage in AC generators zare, F. Abadi, J. Ghosh, Arindam - This paper presents several shaft voltage reduction techniques for doubly-fed induction generators in wind turbine applications. These techniques includes: pulse width modulated voltage without zero vectors, multi-level inverters with proper PWM strategy, better generator design to minimize effective capacitive couplings in shaft voltage, active common-mode filter, reducing DC-link voltage and increasing modulation index. These methods have been verified with mathematical analysis and simulations. 2009 Conference Paper http://hdl.handle.net/20.500.11937/25643 2009 13th European Conference on Power Electronics and Applications (EPE 2009) restricted
spellingShingle zare, F.
Abadi, J.
Ghosh, Arindam
Different approaches to reduce shaft voltage in AC generators
title Different approaches to reduce shaft voltage in AC generators
title_full Different approaches to reduce shaft voltage in AC generators
title_fullStr Different approaches to reduce shaft voltage in AC generators
title_full_unstemmed Different approaches to reduce shaft voltage in AC generators
title_short Different approaches to reduce shaft voltage in AC generators
title_sort different approaches to reduce shaft voltage in ac generators
url http://hdl.handle.net/20.500.11937/25643