Measuring toe clearance using a wireless inertial sensing device

Tripping and slipping falls are serious health concerns for the elderly because they incur high medical costs and can result in life threatening injuries i.e., internal bleeding. Recently there has been an increased interest in the development of portable inertial sensing devices for measuring human...

Full description

Bibliographic Details
Main Authors: Lai, D., Begg, R., Charry, E., Palaniswami, M., Hill, Keith
Format: Conference Paper
Published: 2008
Online Access:http://hdl.handle.net/20.500.11937/25623
_version_ 1848751760364011520
author Lai, D.
Begg, R.
Charry, E.
Palaniswami, M.
Hill, Keith
author_facet Lai, D.
Begg, R.
Charry, E.
Palaniswami, M.
Hill, Keith
author_sort Lai, D.
building Curtin Institutional Repository
collection Online Access
description Tripping and slipping falls are serious health concerns for the elderly because they incur high medical costs and can result in life threatening injuries i.e., internal bleeding. Recently there has been an increased interest in the development of portable inertial sensing devices for measuring human movement. These devices employ acceleration and angular data to obtain limb motion such as velocity and displacement through integration of acceleration values. In this paper, we investigate the performance of a wireless inertial sensing device for monitoring vertical toe clearance during walking. It has been demonstrated that variability in minimum toe clearance (MTC) which occurs during the swing phase is a sensitive falls risk predictor. Our device is composed of a tri-axis accelerometer and dual-axis gyroscope wirelessly connected through the use of Crossbow motes. The vertical toe clearance is obtained through double integration of the resultant acceleration in the vertical direction. We have performed zero base, treadmill and intersubject experiments to investigate device performance to environmental variations and compared the calculated toe clearance against measurements made by an Optotrak motion system. It was found that device outputs were approximately independent of small ambient temperature variations, had a reliable range of 20m indoors and 50m outdoors and a maximum transmission rate of 20 packets/s. Toe clearance measurements coincided with Optotrak measurement trends but suffered from cumulative integration errors over time. The identification, quantification and reduction of these errors are intricate but important further research issues. © 2008 IEEE.
first_indexed 2025-11-14T07:57:51Z
format Conference Paper
id curtin-20.500.11937-25623
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:57:51Z
publishDate 2008
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-256232017-09-13T15:18:39Z Measuring toe clearance using a wireless inertial sensing device Lai, D. Begg, R. Charry, E. Palaniswami, M. Hill, Keith Tripping and slipping falls are serious health concerns for the elderly because they incur high medical costs and can result in life threatening injuries i.e., internal bleeding. Recently there has been an increased interest in the development of portable inertial sensing devices for measuring human movement. These devices employ acceleration and angular data to obtain limb motion such as velocity and displacement through integration of acceleration values. In this paper, we investigate the performance of a wireless inertial sensing device for monitoring vertical toe clearance during walking. It has been demonstrated that variability in minimum toe clearance (MTC) which occurs during the swing phase is a sensitive falls risk predictor. Our device is composed of a tri-axis accelerometer and dual-axis gyroscope wirelessly connected through the use of Crossbow motes. The vertical toe clearance is obtained through double integration of the resultant acceleration in the vertical direction. We have performed zero base, treadmill and intersubject experiments to investigate device performance to environmental variations and compared the calculated toe clearance against measurements made by an Optotrak motion system. It was found that device outputs were approximately independent of small ambient temperature variations, had a reliable range of 20m indoors and 50m outdoors and a maximum transmission rate of 20 packets/s. Toe clearance measurements coincided with Optotrak measurement trends but suffered from cumulative integration errors over time. The identification, quantification and reduction of these errors are intricate but important further research issues. © 2008 IEEE. 2008 Conference Paper http://hdl.handle.net/20.500.11937/25623 10.1109/ISSNIP.2008.4762017 restricted
spellingShingle Lai, D.
Begg, R.
Charry, E.
Palaniswami, M.
Hill, Keith
Measuring toe clearance using a wireless inertial sensing device
title Measuring toe clearance using a wireless inertial sensing device
title_full Measuring toe clearance using a wireless inertial sensing device
title_fullStr Measuring toe clearance using a wireless inertial sensing device
title_full_unstemmed Measuring toe clearance using a wireless inertial sensing device
title_short Measuring toe clearance using a wireless inertial sensing device
title_sort measuring toe clearance using a wireless inertial sensing device
url http://hdl.handle.net/20.500.11937/25623