Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors

The interface between concrete and steel in reinforced concrete governs the interaction between thetwo types of materials under loading. When the interface is seriously damaged, such that a macro-crack is formed, debonding may take place or large slip may occur, and the load-transferring capacity of...

Full description

Bibliographic Details
Main Authors: Zhu, X., Hao, Hong, Fan, K.
Format: Journal Article
Published: Springer 2013
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/24895
_version_ 1848751555650519040
author Zhu, X.
Hao, Hong
Fan, K.
author_facet Zhu, X.
Hao, Hong
Fan, K.
author_sort Zhu, X.
building Curtin Institutional Repository
collection Online Access
description The interface between concrete and steel in reinforced concrete governs the interaction between thetwo types of materials under loading. When the interface is seriously damaged, such that a macro-crack is formed, debonding may take place or large slip may occur, and the load-transferring capacity of the interface would drop dramatically. This paper presents a novel technique to detect the delamination between the steel bars and concrete in the reinforced concrete structures. The piezoelectriccomponents are mounted on reinforcing bars embedded in RC structures as sensors and actuators to generate the signal, which is sensitive to the delamination between the steel bars and concrete. The experimental study is carried out on two concrete slabs with different debonds between the rebars and concrete. Three parameters are calculated from the measured responses and used to indicate thebonding damage. The test results show that the debond damage between the rebars and concrete can be detected with the embedded piezoelectric sensors and actuators.
first_indexed 2025-11-14T07:54:35Z
format Journal Article
id curtin-20.500.11937-24895
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:54:35Z
publishDate 2013
publisher Springer
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-248952017-09-13T15:13:27Z Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors Zhu, X. Hao, Hong Fan, K. Debond Reinforced concrete Embedded piezoelectric actuators/sensors Delamination The interface between concrete and steel in reinforced concrete governs the interaction between thetwo types of materials under loading. When the interface is seriously damaged, such that a macro-crack is formed, debonding may take place or large slip may occur, and the load-transferring capacity of the interface would drop dramatically. This paper presents a novel technique to detect the delamination between the steel bars and concrete in the reinforced concrete structures. The piezoelectriccomponents are mounted on reinforcing bars embedded in RC structures as sensors and actuators to generate the signal, which is sensitive to the delamination between the steel bars and concrete. The experimental study is carried out on two concrete slabs with different debonds between the rebars and concrete. Three parameters are calculated from the measured responses and used to indicate thebonding damage. The test results show that the debond damage between the rebars and concrete can be detected with the embedded piezoelectric sensors and actuators. 2013 Journal Article http://hdl.handle.net/20.500.11937/24895 10.1007/s13349-013-0039-2 Springer restricted
spellingShingle Debond
Reinforced concrete
Embedded piezoelectric actuators/sensors
Delamination
Zhu, X.
Hao, Hong
Fan, K.
Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors
title Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors
title_full Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors
title_fullStr Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors
title_full_unstemmed Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors
title_short Detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors
title_sort detection of delamination between steel bars and concrete using embedded piezoelectric actuators/sensors
topic Debond
Reinforced concrete
Embedded piezoelectric actuators/sensors
Delamination
url http://hdl.handle.net/20.500.11937/24895