A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System
This thesis presents a reliable and cost effective technique that calls for reconfiguration of the existing converters of a typical Doubly Fed Induction Generator to include a coil of low internal resistance. A coil within the DC link is the only hardware component required to implement this techniq...
| Main Author: | |
|---|---|
| Format: | Thesis |
| Language: | English |
| Published: |
Curtin University
2015
|
| Online Access: | http://hdl.handle.net/20.500.11937/2397 |
| _version_ | 1848743943459569664 |
|---|---|
| author | Khamaira, Mahmoud Yousef |
| author_facet | Khamaira, Mahmoud Yousef |
| author_sort | Khamaira, Mahmoud Yousef |
| building | Curtin Institutional Repository |
| collection | Online Access |
| description | This thesis presents a reliable and cost effective technique that calls for reconfiguration of the existing converters of a typical Doubly Fed Induction Generator to include a coil of low internal resistance. A coil within the DC link is the only hardware component required to implement this technique. With a proper control scheme, activated during fault conditions, this coil can provide the same degree of performance as a superconducting magnetic energy storage unit during fault conditions. |
| first_indexed | 2025-11-14T05:53:36Z |
| format | Thesis |
| id | curtin-20.500.11937-2397 |
| institution | Curtin University Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-14T05:53:36Z |
| publishDate | 2015 |
| publisher | Curtin University |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | curtin-20.500.11937-23972017-02-20T06:37:03Z A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System Khamaira, Mahmoud Yousef This thesis presents a reliable and cost effective technique that calls for reconfiguration of the existing converters of a typical Doubly Fed Induction Generator to include a coil of low internal resistance. A coil within the DC link is the only hardware component required to implement this technique. With a proper control scheme, activated during fault conditions, this coil can provide the same degree of performance as a superconducting magnetic energy storage unit during fault conditions. 2015 Thesis http://hdl.handle.net/20.500.11937/2397 en Curtin University fulltext |
| spellingShingle | Khamaira, Mahmoud Yousef A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System |
| title | A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System |
| title_full | A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System |
| title_fullStr | A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System |
| title_full_unstemmed | A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System |
| title_short | A New Converter Station Topology to Improve the Overall Performance of a Doubly Fed Induction Generator-Based Wind Energy Conversion System |
| title_sort | new converter station topology to improve the overall performance of a doubly fed induction generator-based wind energy conversion system |
| url | http://hdl.handle.net/20.500.11937/2397 |