Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis

Capillary trapping has been identified as a fast and effective method to render injected carbon dioxide (CO2) immobile as disconnected pore-scale droplets surrounded by brine. We measure trapped CO2 saturations in sandstones at conditions representative of storage locations. We compare the unsteady...

Full description

Bibliographic Details
Main Authors: Pentland, C., Iglauer, Stefan, El-Maghraby, R., Okabe, H., Tsuchiya, Y., Blunt, M.
Other Authors: SPE
Format: Conference Paper
Published: SPE 2010
Online Access:http://hdl.handle.net/20.500.11937/23493
_version_ 1848751167213928448
author Pentland, C.
Iglauer, Stefan
El-Maghraby, R.
Okabe, H.
Tsuchiya, Y.
Blunt, M.
author2 SPE
author_facet SPE
Pentland, C.
Iglauer, Stefan
El-Maghraby, R.
Okabe, H.
Tsuchiya, Y.
Blunt, M.
author_sort Pentland, C.
building Curtin Institutional Repository
collection Online Access
description Capillary trapping has been identified as a fast and effective method to render injected carbon dioxide (CO2) immobile as disconnected pore-scale droplets surrounded by brine. We measure trapped CO2 saturations in sandstones at conditions representative of storage locations. We compare the unsteady state and porous plate methods of achieving initial CO2 saturations before waterflooding to reach residual saturation. Brine and CO2 are equilibrated prior to injection to ensure immiscible displacements occur on the pore scale. The problems faced with un-equilibrated phases are discussed.The unsteady state and porous plate methods are shown to give different results in terms of maximum initial and residual saturations for Berea sandstone samples. With the unsteady state method maximum residual CO2 saturations of 25-28% are measured for corresponding maximum initial saturations of 35-40%. With the porous plate method a maximum residual saturation of 37% is measured for a maximum initial saturation of 90%. The implications for coreflood method selection during data gathering are discussed. The porous plate results are compared with oil-brine porous plate saturations measured on the same samples. CO2-brine residual saturations are shown to be slightly lower than the corresponding oil-brine measurements. We suggest that considerable carbon dioxide capillary trapping is possible in clean sandstones and discuss the implications for carbon storage in aquifers.
first_indexed 2025-11-14T07:48:25Z
format Conference Paper
id curtin-20.500.11937-23493
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:48:25Z
publishDate 2010
publisher SPE
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-234932017-09-13T16:04:40Z Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis Pentland, C. Iglauer, Stefan El-Maghraby, R. Okabe, H. Tsuchiya, Y. Blunt, M. SPE Capillary trapping has been identified as a fast and effective method to render injected carbon dioxide (CO2) immobile as disconnected pore-scale droplets surrounded by brine. We measure trapped CO2 saturations in sandstones at conditions representative of storage locations. We compare the unsteady state and porous plate methods of achieving initial CO2 saturations before waterflooding to reach residual saturation. Brine and CO2 are equilibrated prior to injection to ensure immiscible displacements occur on the pore scale. The problems faced with un-equilibrated phases are discussed.The unsteady state and porous plate methods are shown to give different results in terms of maximum initial and residual saturations for Berea sandstone samples. With the unsteady state method maximum residual CO2 saturations of 25-28% are measured for corresponding maximum initial saturations of 35-40%. With the porous plate method a maximum residual saturation of 37% is measured for a maximum initial saturation of 90%. The implications for coreflood method selection during data gathering are discussed. The porous plate results are compared with oil-brine porous plate saturations measured on the same samples. CO2-brine residual saturations are shown to be slightly lower than the corresponding oil-brine measurements. We suggest that considerable carbon dioxide capillary trapping is possible in clean sandstones and discuss the implications for carbon storage in aquifers. 2010 Conference Paper http://hdl.handle.net/20.500.11937/23493 10.2118/138476-MS SPE restricted
spellingShingle Pentland, C.
Iglauer, Stefan
El-Maghraby, R.
Okabe, H.
Tsuchiya, Y.
Blunt, M.
Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis
title Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis
title_full Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis
title_fullStr Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis
title_full_unstemmed Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis
title_short Measurement of Supercritical Carbon Dioxide Capillary Trapping in Core Analysis
title_sort measurement of supercritical carbon dioxide capillary trapping in core analysis
url http://hdl.handle.net/20.500.11937/23493