End-winding effect on shaft voltage in AC generators

This paper presents effects of end-winding on shaft voltage in AC generators. A variety of design parameters have been considered to calculate the parasitic capacitive couplings in the machine structure with Finite Elements simulations and mathematical calculations. End-winding capacitances have als...

Full description

Bibliographic Details
Main Authors: Abadi, J., zare, F., Ghosh, Arindam
Other Authors: -
Format: Conference Paper
Published: Institute of Electrical and Electronics Engineers ( IEEE ) 2009
Online Access:http://hdl.handle.net/20.500.11937/23191
_version_ 1848751081598746624
author Abadi, J.
zare, F.
Ghosh, Arindam
author2 -
author_facet -
Abadi, J.
zare, F.
Ghosh, Arindam
author_sort Abadi, J.
building Curtin Institutional Repository
collection Online Access
description This paper presents effects of end-winding on shaft voltage in AC generators. A variety of design parameters have been considered to calculate the parasitic capacitive couplings in the machine structure with Finite Elements simulations and mathematical calculations. End-winding capacitances have also been calculated to have a precise estimation of shaft voltage and its relationship with design parameters in AC generators.
first_indexed 2025-11-14T07:47:03Z
format Conference Paper
id curtin-20.500.11937-23191
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:47:03Z
publishDate 2009
publisher Institute of Electrical and Electronics Engineers ( IEEE )
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-231912017-02-28T01:37:22Z End-winding effect on shaft voltage in AC generators Abadi, J. zare, F. Ghosh, Arindam - This paper presents effects of end-winding on shaft voltage in AC generators. A variety of design parameters have been considered to calculate the parasitic capacitive couplings in the machine structure with Finite Elements simulations and mathematical calculations. End-winding capacitances have also been calculated to have a precise estimation of shaft voltage and its relationship with design parameters in AC generators. 2009 Conference Paper http://hdl.handle.net/20.500.11937/23191 Institute of Electrical and Electronics Engineers ( IEEE ) restricted
spellingShingle Abadi, J.
zare, F.
Ghosh, Arindam
End-winding effect on shaft voltage in AC generators
title End-winding effect on shaft voltage in AC generators
title_full End-winding effect on shaft voltage in AC generators
title_fullStr End-winding effect on shaft voltage in AC generators
title_full_unstemmed End-winding effect on shaft voltage in AC generators
title_short End-winding effect on shaft voltage in AC generators
title_sort end-winding effect on shaft voltage in ac generators
url http://hdl.handle.net/20.500.11937/23191