Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres

A study on the flexural strength of hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres in an intra-ply configuration is presented in this paper. The flexural strength was obtained from the three point bend test in accordance with ASTM: D790-10 at various span-to-depth ratios. No...

Full description

Bibliographic Details
Main Authors: Dong, Jonathan, Davies, Ian
Format: Journal Article
Published: Elsevier 2014
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/22196
_version_ 1848750802853691392
author Dong, Jonathan
Davies, Ian
author_facet Dong, Jonathan
Davies, Ian
author_sort Dong, Jonathan
building Curtin Institutional Repository
collection Online Access
description A study on the flexural strength of hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres in an intra-ply configuration is presented in this paper. The flexural strength was obtained from the three point bend test in accordance with ASTM: D790-10 at various span-to-depth ratios. Nonlinear large displacement finite element analysis (FEA) and the classic lamination theory (CLT) were employed to model the flexural behaviour of the hybrid composites. The models were validated using the experiment specimens from a previous study. With the aid of the developed models, the effects of fibre volume fractions, hybrid ratio and span-to-depth ratio were studied. It is shown that the flexural strength increases with span-to-depth ratio and converges when the span-to-depth ratio is greater than 32. Hybridisation can be used to improve the flexural strength. The hybridisation phenomena are dependent on the strength ratios of carbon/epoxy and glass/epoxy laminas. The overall maximum flexural hybrid effect is achieved when the hybrid ratio is 0.25 ([02G/06C]) when both Vfc and Vfg are 70%. The strength increases are 16.6% and 42.58% when compared with those of the full carbon and glass configurations, respectively. The overall maximum tensile hybrid effect is achieved when the hybrid ratio is 0.125 ([0G/07C]) when Vfc is 30% and Vfg is 50%.
first_indexed 2025-11-14T07:42:38Z
format Journal Article
id curtin-20.500.11937-22196
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:42:38Z
publishDate 2014
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-221962017-09-13T16:05:29Z Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres Dong, Jonathan Davies, Ian Flexural strength Carbon fibre Polymer-matrix composites Tensile strength Hybrid Glass fibre A study on the flexural strength of hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres in an intra-ply configuration is presented in this paper. The flexural strength was obtained from the three point bend test in accordance with ASTM: D790-10 at various span-to-depth ratios. Nonlinear large displacement finite element analysis (FEA) and the classic lamination theory (CLT) were employed to model the flexural behaviour of the hybrid composites. The models were validated using the experiment specimens from a previous study. With the aid of the developed models, the effects of fibre volume fractions, hybrid ratio and span-to-depth ratio were studied. It is shown that the flexural strength increases with span-to-depth ratio and converges when the span-to-depth ratio is greater than 32. Hybridisation can be used to improve the flexural strength. The hybridisation phenomena are dependent on the strength ratios of carbon/epoxy and glass/epoxy laminas. The overall maximum flexural hybrid effect is achieved when the hybrid ratio is 0.25 ([02G/06C]) when both Vfc and Vfg are 70%. The strength increases are 16.6% and 42.58% when compared with those of the full carbon and glass configurations, respectively. The overall maximum tensile hybrid effect is achieved when the hybrid ratio is 0.125 ([0G/07C]) when Vfc is 30% and Vfg is 50%. 2014 Journal Article http://hdl.handle.net/20.500.11937/22196 10.1016/j.matdes.2013.08.087 Elsevier restricted
spellingShingle Flexural strength
Carbon fibre
Polymer-matrix composites
Tensile strength
Hybrid
Glass fibre
Dong, Jonathan
Davies, Ian
Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres
title Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres
title_full Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres
title_fullStr Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres
title_full_unstemmed Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres
title_short Flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by S-2 glass and T700S carbon fibres
title_sort flexural and tensile strengths of unidirectional hybrid epoxy composites reinforced by s-2 glass and t700s carbon fibres
topic Flexural strength
Carbon fibre
Polymer-matrix composites
Tensile strength
Hybrid
Glass fibre
url http://hdl.handle.net/20.500.11937/22196