Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters

This paper presents dynamic hysteresis band height control to reduce the overshoot and undershoot issue on output voltage caused by load change. The converters in this study are Boost and Positive Buck-Boost (PBB) converters. PBB has been controlled to work in a step up conversion and avoid overshoo...

Full description

Bibliographic Details
Main Authors: Boora, A., zare, F., Ghosh, Arindam
Other Authors: -
Format: Conference Paper
Published: Institute of Electrical and Electronics Engineers ( IEEE ) 2009
Online Access:http://hdl.handle.net/20.500.11937/20248
_version_ 1848750253666205696
author Boora, A.
zare, F.
Ghosh, Arindam
author2 -
author_facet -
Boora, A.
zare, F.
Ghosh, Arindam
author_sort Boora, A.
building Curtin Institutional Repository
collection Online Access
description This paper presents dynamic hysteresis band height control to reduce the overshoot and undershoot issue on output voltage caused by load change. The converters in this study are Boost and Positive Buck-Boost (PBB) converters. PBB has been controlled to work in a step up conversion and avoid overshoot when load is changed. Simulation and experimental results have been presented to verify the proposed method.
first_indexed 2025-11-14T07:33:54Z
format Conference Paper
id curtin-20.500.11937-20248
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:33:54Z
publishDate 2009
publisher Institute of Electrical and Electronics Engineers ( IEEE )
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-202482017-02-28T01:34:53Z Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters Boora, A. zare, F. Ghosh, Arindam - This paper presents dynamic hysteresis band height control to reduce the overshoot and undershoot issue on output voltage caused by load change. The converters in this study are Boost and Positive Buck-Boost (PBB) converters. PBB has been controlled to work in a step up conversion and avoid overshoot when load is changed. Simulation and experimental results have been presented to verify the proposed method. 2009 Conference Paper http://hdl.handle.net/20.500.11937/20248 Institute of Electrical and Electronics Engineers ( IEEE ) restricted
spellingShingle Boora, A.
zare, F.
Ghosh, Arindam
Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters
title Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters
title_full Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters
title_fullStr Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters
title_full_unstemmed Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters
title_short Application of dynamic hysteresis band height control to improve output voltage transient in boost and Positive Buck-Boost converters
title_sort application of dynamic hysteresis band height control to improve output voltage transient in boost and positive buck-boost converters
url http://hdl.handle.net/20.500.11937/20248