Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters

This study investigated the influence of flow interruptions on the filtration performance of two different multi-layered fibrous filters during liquid aerosol filtration. It was found that both types of filters experienced a significant secondary loading stage, though they had reached a steady state...

Full description

Bibliographic Details
Main Authors: Bredin, Arne, Mullins, Benjamin
Format: Journal Article
Published: Pergamon 2012
Online Access:http://hdl.handle.net/20.500.11937/18731
_version_ 1848749828754898944
author Bredin, Arne
Mullins, Benjamin
author_facet Bredin, Arne
Mullins, Benjamin
author_sort Bredin, Arne
building Curtin Institutional Repository
collection Online Access
description This study investigated the influence of flow interruptions on the filtration performance of two different multi-layered fibrous filters during liquid aerosol filtration. It was found that both types of filters experienced a significant secondary loading stage, though they had reached a steady state for continuous flow. The filters showed distinctive increases in pressure drop and filter saturation until a second equilibrium state was reached. This second equilibrium state was attributed to a rearrangement of liquid in the filter during the breaks, clogging previously free passages. The ratio of shear and capillary forces was found to determine whether these passages were able to be “cleaned” once airflow was recommenced. Based on these findings, the airflow required to clean fully saturated filters was investigated and a phenomenological model developed to describe this behaviour. Furthermore, it was found that filters could be cleaned and reused, whereby they would return to one of the previous steady states (continuous or discontinuous flow). The experiments conducted in this work represent a more realistic test for oil-mist (or coalescing) filters than typical laboratory testing. Furthermore, it is hoped that they will help to bridge the gap between laboratory and field test results.
first_indexed 2025-11-14T07:27:09Z
format Journal Article
id curtin-20.500.11937-18731
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:27:09Z
publishDate 2012
publisher Pergamon
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-187312019-02-19T05:34:59Z Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters Bredin, Arne Mullins, Benjamin This study investigated the influence of flow interruptions on the filtration performance of two different multi-layered fibrous filters during liquid aerosol filtration. It was found that both types of filters experienced a significant secondary loading stage, though they had reached a steady state for continuous flow. The filters showed distinctive increases in pressure drop and filter saturation until a second equilibrium state was reached. This second equilibrium state was attributed to a rearrangement of liquid in the filter during the breaks, clogging previously free passages. The ratio of shear and capillary forces was found to determine whether these passages were able to be “cleaned” once airflow was recommenced. Based on these findings, the airflow required to clean fully saturated filters was investigated and a phenomenological model developed to describe this behaviour. Furthermore, it was found that filters could be cleaned and reused, whereby they would return to one of the previous steady states (continuous or discontinuous flow). The experiments conducted in this work represent a more realistic test for oil-mist (or coalescing) filters than typical laboratory testing. Furthermore, it is hoped that they will help to bridge the gap between laboratory and field test results. 2012 Journal Article http://hdl.handle.net/20.500.11937/18731 10.1016/j.seppur.2012.02.009 Pergamon fulltext
spellingShingle Bredin, Arne
Mullins, Benjamin
Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
title Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
title_full Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
title_fullStr Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
title_full_unstemmed Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
title_short Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
title_sort influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
url http://hdl.handle.net/20.500.11937/18731