Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions
Introduction: Falls in hospitals and residential care facilities commonly occur near the bed. The aim of this study was to investigate the accuracy of a continuously wearable, batteryless, low power and low cost monitoring device (Wearable Wireless Identification and Sensing Platform) with a single...
| Main Authors: | , , , |
|---|---|
| Format: | Journal Article |
| Published: |
Elsevier
2014
|
| Subjects: | |
| Online Access: | http://hdl.handle.net/20.500.11937/17712 |
| _version_ | 1848749536620576768 |
|---|---|
| author | Ranasinghe, D. Shinmoto Torres, R. Hill, Keith Visvanathan, R. |
| author_facet | Ranasinghe, D. Shinmoto Torres, R. Hill, Keith Visvanathan, R. |
| author_sort | Ranasinghe, D. |
| building | Curtin Institutional Repository |
| collection | Online Access |
| description | Introduction: Falls in hospitals and residential care facilities commonly occur near the bed. The aim of this study was to investigate the accuracy of a continuously wearable, batteryless, low power and low cost monitoring device (Wearable Wireless Identification and Sensing Platform) with a single kinematic sensor capable of real-time monitoring to automatically detect bed entry and exit events. Materials and methods: Three dimensional acceleration readings and the strength of the transmitted signal from the WISP was interpreted to identify bed exit events and sensitivity, specificity and Receiving Operator Curves (ROC) were determined. Results: The sensor located over sternum method performed best with sensitivity and specificity values of 92.8% and 97.5% respectively for detecting bed entry and values of 90.4% and 93.80% respectively for bed exit. On the other hand, the sensor-on-mattress algorithm achieved sensitivity and specificity values of 84.2% and 97.4% respectively for bed entry and 79% and 97.4% for bed exit detection. Conclusion: The WISP located over the sternum method is the preferred method to detect bed entry and exit. However, further work in frail older people is required to confirm the performance of this method. |
| first_indexed | 2025-11-14T07:22:30Z |
| format | Journal Article |
| id | curtin-20.500.11937-17712 |
| institution | Curtin University Malaysia |
| institution_category | Local University |
| last_indexed | 2025-11-14T07:22:30Z |
| publishDate | 2014 |
| publisher | Elsevier |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | curtin-20.500.11937-177122017-09-13T15:43:29Z Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions Ranasinghe, D. Shinmoto Torres, R. Hill, Keith Visvanathan, R. Radio frequency identification Bed exit alarm Elderly Wearable sensor Postural transitions Introduction: Falls in hospitals and residential care facilities commonly occur near the bed. The aim of this study was to investigate the accuracy of a continuously wearable, batteryless, low power and low cost monitoring device (Wearable Wireless Identification and Sensing Platform) with a single kinematic sensor capable of real-time monitoring to automatically detect bed entry and exit events. Materials and methods: Three dimensional acceleration readings and the strength of the transmitted signal from the WISP was interpreted to identify bed exit events and sensitivity, specificity and Receiving Operator Curves (ROC) were determined. Results: The sensor located over sternum method performed best with sensitivity and specificity values of 92.8% and 97.5% respectively for detecting bed entry and values of 90.4% and 93.80% respectively for bed exit. On the other hand, the sensor-on-mattress algorithm achieved sensitivity and specificity values of 84.2% and 97.4% respectively for bed entry and 79% and 97.4% for bed exit detection. Conclusion: The WISP located over the sternum method is the preferred method to detect bed entry and exit. However, further work in frail older people is required to confirm the performance of this method. 2014 Journal Article http://hdl.handle.net/20.500.11937/17712 10.1016/j.gaitpost.2013.06.009 Elsevier restricted |
| spellingShingle | Radio frequency identification Bed exit alarm Elderly Wearable sensor Postural transitions Ranasinghe, D. Shinmoto Torres, R. Hill, Keith Visvanathan, R. Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions |
| title | Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions |
| title_full | Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions |
| title_fullStr | Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions |
| title_full_unstemmed | Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions |
| title_short | Low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions |
| title_sort | low cost and batteryless sensor-enabled radio frequency identification tag based approaches to identify patient bed entry and exit posture transitions |
| topic | Radio frequency identification Bed exit alarm Elderly Wearable sensor Postural transitions |
| url | http://hdl.handle.net/20.500.11937/17712 |