Nanocrystalline silver dressings significantly influence bioimpedance spectroscopy measurements of fluid volumes in burns patients
Bioimpedance spectroscopy (BIS) is a tool utilized in health care to investigate body composition and fluid distribution. Limited research has addressed the clinical use of BIS in burns. This study aimed to examine the effects of silver dressings on BIS measurements in burns patients. BIS measuremen...
| Main Authors: | Grisbrook, Tiffany School of Physiotherapy and Exercise Science 256339B, Kenworthy, P., Phillips, M., Wood, F., Edgar, D. |
|---|---|
| Format: | Journal Article |
| Published: |
Pergamon Press
2016
|
| Online Access: | http://hdl.handle.net/20.500.11937/17021 |
Similar Items
Addressing the Barriers to Bioimpedance Spectroscopy Use in Major Burns: Alternate Electrode Placement
by: Kenworthy, P., et al.
Published: (2017)
by: Kenworthy, P., et al.
Published: (2017)
Bioimpedance spectroscopy: A technique to monitor interventions for swelling in minor burns
by: Kenworthy, P., et al.
Published: (2017)
by: Kenworthy, P., et al.
Published: (2017)
Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
by: Grisbrook, Tiffany, et al.
Published: (2015)
by: Grisbrook, Tiffany, et al.
Published: (2015)
Measurement of acute edema shifts in human burn survivors - The reliability and sensitivity of bioimpedence spectroscopy as an objective clinical measure
by: Edgar, D., et al.
Published: (2009)
by: Edgar, D., et al.
Published: (2009)
Monitoring wound healing in minor burns-A novel approach
by: Kenworthy, P., et al.
Published: (2017)
by: Kenworthy, P., et al.
Published: (2017)
Bioimpedance spectroscopy is a valid and reliable measure of edema following hand burn injury (Part 1-method validation)
by: Edwick, Dale, et al.
Published: (2020)
by: Edwick, Dale, et al.
Published: (2020)
An objective measure for the assessment and management of fluid shifts in acute major burns
by: Kenworthy, P., et al.
Published: (2018)
by: Kenworthy, P., et al.
Published: (2018)
The effectiveness of session rating of perceived exertion to monitor resistance training load in acute burns patients
by: Grisbrook, Tiffany, et al.
Published: (2016)
by: Grisbrook, Tiffany, et al.
Published: (2016)
Bioimpedance spectroscopy system for characterization of cancer cells
by: Al-hashimi, Ahmad, et al.
Published: (2014)
by: Al-hashimi, Ahmad, et al.
Published: (2014)
Demonstration of the test-retest reliability and sensitivity of the Lower Limb Functional Index-10 as a measure of functional recovery post burn injury: a cross-sectional repeated measures study design
by: Ryland, M., et al.
Published: (2016)
by: Ryland, M., et al.
Published: (2016)
The effect of exercise training on pulmonary function and aerobic capacity in adults with burn
by: Grisbrook, Tiffany, et al.
Published: (2012)
by: Grisbrook, Tiffany, et al.
Published: (2012)
Microbiological And Angiogenic Properties Of Burn Injuries Treated With Tualang Honey Versus Silver-Based Dressing
by: Nasir, Nur Azida Mohd
Published: (2012)
by: Nasir, Nur Azida Mohd
Published: (2012)
Burn-injured adults with long term functional impairments demonstrate the same response to resistance training as uninjured controls
by: Grisbrook, Tiffany, et al.
Published: (2013)
by: Grisbrook, Tiffany, et al.
Published: (2013)
Lower limb functional outcome assessment following burn injury: A novel use for 3D laboratory-based movement analysis
by: Grisbrook, Tiffany, et al.
Published: (2010)
by: Grisbrook, Tiffany, et al.
Published: (2010)
Exercise training to improve health related quality of life in long term survivors of major burn injury: A matched controlled study
by: Grisbrook, Tiffany, et al.
Published: (2012)
by: Grisbrook, Tiffany, et al.
Published: (2012)
Design of a reconfigurable, modular and multi-channel
bioimpedance spectroscopy system
by: Al-hashimi, Ahmad, et al.
Published: (2017)
by: Al-hashimi, Ahmad, et al.
Published: (2017)
Resistance training for rehabilitation after burn injury: A systematic literature review & meta-analysis
by: Gittings, P., et al.
Published: (2017)
by: Gittings, P., et al.
Published: (2017)
A study on the microbiological and angiogenic properties of burn injuries treated with tualang honey versus
silver based dressing
by: Halim, Ahmad Sukari, et al.
Published: (2011)
by: Halim, Ahmad Sukari, et al.
Published: (2011)
Demonstration of the use of the ICF framework in detailing complex functional deficits after major burn
by: Grisbrook, Tiffany, et al.
Published: (2012)
by: Grisbrook, Tiffany, et al.
Published: (2012)
Burn wound dressing using honey hydrogel
versus hydrogel
by: Amnah, Ab Halim
Published: (2006)
by: Amnah, Ab Halim
Published: (2006)
Pulmonary function, exercise capacity and physical activity participation in adults following burn
by: Willis, C., et al.
Published: (2011)
by: Willis, C., et al.
Published: (2011)
Enhancing the clinical utility of the Burn Specific Health Scale-Brief: Not just for major burns
by: Finlay, V., et al.
Published: (2014)
by: Finlay, V., et al.
Published: (2014)
Development of a psycho-educational anti-doping intervention program for emerging athletes
by: Jalleh, Geoffrey, et al.
Published: (2012)
by: Jalleh, Geoffrey, et al.
Published: (2012)
Nursing Care of Clients With Burns
by: Rowe, S., et al.
Published: (2011)
by: Rowe, S., et al.
Published: (2011)
Nursing care of people with burns
by: Rowe, S., et al.
Published: (2013)
by: Rowe, S., et al.
Published: (2013)
Volume Measurement Using the Polhemus FastSCAN 3D Laser Scanning: A Novel Application for Burns Clinical Research
by: Edgar, D., et al.
Published: (2008)
by: Edgar, D., et al.
Published: (2008)
Volume Measurement Using the Polhemus FastSCAN 3D Laser Scanning : A Novel Application for Burns Clinical Research
by: Edgar, D., et al.
Published: (2008)
by: Edgar, D., et al.
Published: (2008)
Honey hydrogel dressing to treat burn wound in rats - a preliminary report
by: Mohd Zohdi, Rozaini, et al.
Published: (2012)
by: Mohd Zohdi, Rozaini, et al.
Published: (2012)
Resistivity coefficients for body composition analysis using bioimpedance spectroscopy: Effects of body dominance and mixture theory algorithm
by: Ward, L., et al.
Published: (2015)
by: Ward, L., et al.
Published: (2015)
Evaluation of a Streamlined Model of Care for Minor Burn Patients
by: Finlay, V., et al.
Published: (2014)
by: Finlay, V., et al.
Published: (2014)
Towards more efficient burn care: Identifying factors associated with good quality of life post-burn
by: Finlay, V., et al.
Published: (2015)
by: Finlay, V., et al.
Published: (2015)
Prognosis Of Non-Dialysis Dependent (Ndd) Chronic Kidney Disease (CKD) Patients And Outcomes Of Diuretic Therapy By Using Bioimpedance Spectroscopy
by: Khan, Yusra Habib
Published: (2017)
by: Khan, Yusra Habib
Published: (2017)
The effects of dialysis on body bioimpedance / Nurulnisa Nor Azman
by: Nurulnisa , Nor Azman
Published: (2012)
by: Nurulnisa , Nor Azman
Published: (2012)
Burn and cancer risk: A state-wide logitudinal analysis
by: Duke, Janine, et al.
Published: (2011)
by: Duke, Janine, et al.
Published: (2011)
Using the Burn Specific Health Scale-Brief as a measure of quality of life after a burn - What score should clinicians expect?
by: Kvannli, L., et al.
Published: (2011)
by: Kvannli, L., et al.
Published: (2011)
Mental health and itch in burns patients: Potential associations
by: McGarry, Sarah, et al.
Published: (2016)
by: McGarry, Sarah, et al.
Published: (2016)
Core outcomes for adult burn survivors: A clinical overview
by: Falder, S., et al.
Published: (2009)
by: Falder, S., et al.
Published: (2009)
On dress and adornment
by: Schilo, Ann
Published: (2010)
by: Schilo, Ann
Published: (2010)
Soul Dressing
by: Michaloudis, Ioannis
Published: (2013)
by: Michaloudis, Ioannis
Published: (2013)
Heterotopic Ossification in adults following a burn: A phenomenological analysis
by: Foster, N., et al.
Published: (2017)
by: Foster, N., et al.
Published: (2017)
Similar Items
-
Addressing the Barriers to Bioimpedance Spectroscopy Use in Major Burns: Alternate Electrode Placement
by: Kenworthy, P., et al.
Published: (2017) -
Bioimpedance spectroscopy: A technique to monitor interventions for swelling in minor burns
by: Kenworthy, P., et al.
Published: (2017) -
Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
by: Grisbrook, Tiffany, et al.
Published: (2015) -
Measurement of acute edema shifts in human burn survivors - The reliability and sensitivity of bioimpedence spectroscopy as an objective clinical measure
by: Edgar, D., et al.
Published: (2009) -
Monitoring wound healing in minor burns-A novel approach
by: Kenworthy, P., et al.
Published: (2017)