Water transport due to wick action through concrete

Wick action is the transport of water through a concrete element from a face in contact with water to a drying face as occurs in basements, tunnels, slabs on grade and hollow offshore structures. Water transport through concrete due to wick action is many times greater due to pressure permeability u...

Full description

Bibliographic Details
Main Author: Aldred, James M.
Format: Thesis
Language:English
Published: Curtin University 2008
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/1557
_version_ 1848743700664942592
author Aldred, James M.
author_facet Aldred, James M.
author_sort Aldred, James M.
building Curtin Institutional Repository
collection Online Access
description Wick action is the transport of water through a concrete element from a face in contact with water to a drying face as occurs in basements, tunnels, slabs on grade and hollow offshore structures. Water transport through concrete due to wick action is many times greater due to pressure permeability under typical environmental conditions. Therefore wick action plays an important role in the watertightness and durability of concrete structures. Current models of wick action are based on an equilibrium developing between the rate of water entering concrete by sorptivity and leaving by water vapour diffusion where initial moisture content should not change the steady state rate, only the dominant factor in the early stages.Wick action tests were conducted on concrete specimens of varying initial moisture condition, thickness, orientation and composition over periods ranging up to 450 days. Some wick action tests were conducted at 50% and 75% relative humidity and using a penetrating solution of reduced surface tension. The rate of wick action was found to be inversely proportional to thickness regardless of the initial moisture content of the specimen. Initial saturation was found to significantly increase wick action and moisture flow in ordinary Portland cement (OPC) and hydrophobic (HI) concretes drying at 75% RH and HI concrete drying at 50% RH. The data are consistent with the well documented hysteresis between sorption/desorption isotherms. Concretes containing silica fume (SF) and ground granulated blast-furnace slag (GGBS) did not exhibit such hysteresis. Reducing the surface tension of the pentrating solution profoundly reduced the sorptivity into dried specimens but not the depth of penetration or the steady state wick action rate. Direct measurements on osmotic flow through vacuum saturated specimens showed that osmotic effects had a limited effect on wick action at salt concentrations expected in most environmental conditions.The research demonstrates that desorptivity from the drying surface rather than sorptivity into the wetting surface is the dominant factor determining wick action through concrete. The ease with which desorptivity can be measured and the simple empirical model developed provides practicising engineers with a useful tool to estimate water transport due to wick action through concrete in partially immersed conditions.
first_indexed 2025-11-14T05:49:44Z
format Thesis
id curtin-20.500.11937-1557
institution Curtin University Malaysia
institution_category Local University
language English
last_indexed 2025-11-14T05:49:44Z
publishDate 2008
publisher Curtin University
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-15572017-02-20T06:37:18Z Water transport due to wick action through concrete Aldred, James M. pressure permeability watertightness environmental conditions water transport through concrete wick action durability of concrete structures Wick action is the transport of water through a concrete element from a face in contact with water to a drying face as occurs in basements, tunnels, slabs on grade and hollow offshore structures. Water transport through concrete due to wick action is many times greater due to pressure permeability under typical environmental conditions. Therefore wick action plays an important role in the watertightness and durability of concrete structures. Current models of wick action are based on an equilibrium developing between the rate of water entering concrete by sorptivity and leaving by water vapour diffusion where initial moisture content should not change the steady state rate, only the dominant factor in the early stages.Wick action tests were conducted on concrete specimens of varying initial moisture condition, thickness, orientation and composition over periods ranging up to 450 days. Some wick action tests were conducted at 50% and 75% relative humidity and using a penetrating solution of reduced surface tension. The rate of wick action was found to be inversely proportional to thickness regardless of the initial moisture content of the specimen. Initial saturation was found to significantly increase wick action and moisture flow in ordinary Portland cement (OPC) and hydrophobic (HI) concretes drying at 75% RH and HI concrete drying at 50% RH. The data are consistent with the well documented hysteresis between sorption/desorption isotherms. Concretes containing silica fume (SF) and ground granulated blast-furnace slag (GGBS) did not exhibit such hysteresis. Reducing the surface tension of the pentrating solution profoundly reduced the sorptivity into dried specimens but not the depth of penetration or the steady state wick action rate. Direct measurements on osmotic flow through vacuum saturated specimens showed that osmotic effects had a limited effect on wick action at salt concentrations expected in most environmental conditions.The research demonstrates that desorptivity from the drying surface rather than sorptivity into the wetting surface is the dominant factor determining wick action through concrete. The ease with which desorptivity can be measured and the simple empirical model developed provides practicising engineers with a useful tool to estimate water transport due to wick action through concrete in partially immersed conditions. 2008 Thesis http://hdl.handle.net/20.500.11937/1557 en Curtin University fulltext
spellingShingle pressure permeability
watertightness
environmental conditions
water transport through concrete
wick action
durability of concrete structures
Aldred, James M.
Water transport due to wick action through concrete
title Water transport due to wick action through concrete
title_full Water transport due to wick action through concrete
title_fullStr Water transport due to wick action through concrete
title_full_unstemmed Water transport due to wick action through concrete
title_short Water transport due to wick action through concrete
title_sort water transport due to wick action through concrete
topic pressure permeability
watertightness
environmental conditions
water transport through concrete
wick action
durability of concrete structures
url http://hdl.handle.net/20.500.11937/1557